Environmental Permit No. FEP-02/042/2000/E

       Àô¹Ò³\¥iÃÒ½s¸¹FEP-02/042/2000/E

 

ENVIRONMENTAL IMPACT ASSESSMENT ORDINANCE

(CHAPTER 499)

SECTION 10 & 12

Àô¹Ò¼vÅTµû¦ô±ø¨Ò

(²Ä499³¹)

²Ä10 ¤Î12±ø

 

ENVIRONMENTAL PERMIT TO OPERATE A DESIGNATED PROJECT

Àç¿ì«ü©w¤uµ{¶µ¥ØªºÀô¹Ò³\¥iÃÒ

 

 

PART A (MAIN PERMIT)

A³¡ (³\¥iÃÒ¥D­n³¡¤À)

 

Pursuant to Sections 10 and 12 of the Environmental Impact Assessment Ordinance (EIAO), the Director of Environmental Protection (the Director) grants this environmental permit to the MTR Corporation Limited (hereinafter referred to as the ¡§Permit Holder¡¨) to operate the designated project described in Part B subject to the conditions specified in Part C. The issue of this environmental permit is based on the documents, approvals or permissions described below :

 

®Ú¾Ú¡mÀô¹Ò¼vÅTµû¦ô±ø¨Ò¡n(Àôµû±ø¨Ò)²Ä10¤Î12±øªº³W©w¡AÀô¹Ò«OÅ@¸p¸pªø(¸pªø)±N¥»Àô¹Ò³\¥iÃҧ天­»´äÅK¸ô¦³­­¤½¥q(¤UºÙ ¡§³\¥iÃÒ«ù¦³¤H¡¨)¥HÀç¿ìB³¡©Ò»¡©úªº«ü©w¤uµ{¶µ¥Ø¡A¦ý¶·¿í¦uC³¡©Ò¦C©úªº±ø¥ó¡C¥»Àô¹Ò³\¥iÃÒ¬O¨Ì¾Ú¤U¦C¤å¥ó¡B§å­ã©Î³\¥i¦Óñµo¡G

 

The issue of this Further Environmental Permit is based on the documents, approvals or permissions described below:

 

¥»·sªºÀô¹Ò³\¥iÃÒªºµo¥X¡A¤D¥H¤Uªí©Ò¦Cªº¤å¥ó¡B§å­ã©Î³\¥i§@¬°®Ú¾Ú¡R-

 



Application No.

¥Ó½Ð®Ñ½s¸¹

FEP-085/2007

 



Document in the Register :

µn°O¥U¤Wªº¤å¥ó¡G

(1)       Light Rail Transit (LRT) Extension in Tin Shui Wai Reserve Zone and Grade Separation of the LRT with Pui To Road and Tsing Lun Road in Tuen Mun:

Ÿ     Final Environmental Impact Assessment Report (November 1999)

Ÿ     Final Environmental Impact Assessment Report ¡V Appendices (November 1999)

Ÿ     Executive Summary (November 1999)

Ÿ     Final Environmental Monitoring and Audit Manual

  (EM&A Manual)(November 1999)

(Register No. AEIAR-027/1999) [hereinafter referred to

  as the ¡§EIA Report¡¨]

 

(2)       The Director¡¦s letter of approval of the EIA Report dated 6 January 2000 (ref: (14) in Annex (17) to EP2/N6/06 Pt. 3)

 

(3)       Application for Environmental Permit submitted on 23 September 1999 (Application No. AEP-039/1999)

 

(4)       Environmental Permit No. EP-042/2000 issued on 21 January 2000.

 

(5)       Application document for Variation of Environmental Permit submitted on 7 March 2000 (Application No. VEP- 011/2000)

 

(6)       Environmental Permit No. VEP-011/2000/A/EP-042 issued on 1 April 2000

 

(7)       Application document for Variation of Environmental Permit submitted on 5 October 2000. (Application No. VEP-030/2000)

 

(8)       Environmental Permit No. VEP-030/2000/B/EP-042 issued on 2 November 2000

 

(9)       Application document for Variation of Environmental Permit submitted on 12 December 2000 (Application No. VEP-035/2000)

 

(10)    Environmental Permit No. EP-042/2000/C issued on 10 January 2001

 

(11)    Application document for Variation of Environmental Permit submitted on 9 September 2002 (Application No. VEP-075/2002)

 

(12)    Environmental Permit No. EP-042/2000/D issued on 4 October 2002

 

(13)    Application document for Variation of Environmental Permit submitted on 23 October 2003 (Application No. VEP-119/2003)

 

(14)    Environmental Permit No. EP-042/2000/E issued on 3 November 2003

 

(15)    Application document for Further Environmental Permit submitted on 28 November 2007 (Application No. FEP-085/2007)

 

(1)       ¤Ñ¤ô³ò¹w¯d°Ï»´ÅK¤ä½u¤Î¤ÙªùªM´ç¸ô¤Î«CÅï¸ô¤§»´ÅK¬[ªÅ¸ô­y:

Ÿ     ³Ì²×Àô¹Ò¼vÅTµû¦ô³ø§i(1999¦~11¤ë)

Ÿ     ³Ì²×Àô¹Ò¼vÅTµû¦ô³ø§i - ªþ¿ý(1999¦~11¤ë)

Ÿ     ¦æ¬FºK­n(1999¦~11¤ë)¤Î

Ÿ     ³Ì²×Àô¹ÒºÊ¹î¤Î¼f®Ö¤â¥U(1999¦~11¤ë)

(µn°O¥U½s¸¹ : AEIAR-027/1999) [¤UºÙ ¡§Àôµû³ø§i¡¨]

 

(2)       ¸pªø©ó2000¦~1¤ë6¤éµo¥X¸ÓÀôµû³ø§iªº§å­ã«H

(ÀÉ®×½s¸¹ (14) in Annex (17) to EP2/N6/06 Pt. 3)

 

(3)       ©ó1999¦~9¤ë23¤é´£¥æªºÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹ AEP-039/1999)

 

(4)       ©ó2000¦~1¤ë21¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹ EP-042/2000

 

(5)       ©ó2000¦~3¤ë7¤é´£¥æªº§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹VEP-011/2000)

 

(6)       ©ó2000¦~4¤ë1¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹VEP-011/2000/A/EP-042

 

(7)       ©ó2000¦~10¤ë5¤é´£¥æªº§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹ VEP-030/2000)

 

(8)       ©ó2000¦~11¤ë2¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹VEP-030/2000/B/EP-042

 

(9)       ©ó2000¦~12¤ë12¤é´£¥æªº§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹VEP-035/2000)

 

(10)    ©ó2001¦~1¤ë10¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹EP-042/2000/C

 

(11)    ©ó2002¦~9¤ë9¤é´£¥æªº§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹VEP-075/2002)

 

(12)    ©ó2002¦~10¤ë4¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹EP-042/2000/D

 

(13)    ©ó2003¦~10¤ë23¤é´£¥æªº§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹VEP-119/2003)

 

(14)    ©ó2003¦~11¤ë3¤éñµoªºÀô¹Ò³\¥iÃÒ½s¸¹EP-042/2000/E

 

(15)    ©ó2007¦~11¤ë18¤é´£¥æªº·sªºÀô¹Ò³\¥iÃҥӽФå¥ó(¥Ó½Ð®Ñ½s¸¹FEP-085/2007)

 

 

 

 

 

 

       21 December 2007                                                      

Date

¤é´Á

(WONG Hon-meng)

Principal Environmental Protection Officer (Strategic Assessment)

for Director of Environmental Protection

Àô¹Ò«OÅ@¸p¸pªø

 (­º®uÀô¹Ò«OÅ@¥D¥ô(µ¦²¤µû¦ô) ¶Àº~©ú ¥N¦æ)

 


PART B (DESCRIPTIONS OF DESIGNATED PROJECT)

B³¡ («ü©w¤uµ{¶µ¥Øªº»¡©ú)

 

Hereunder is the description of the designated project mentioned in Part A of this environmental permit:

 

¤U¦C¬°¥»Àô¹Ò³\¥iÃÒA³¡©Ò´£¤Îªº«ü©w¤uµ{¶µ¥Øªº»¡©ú:

 

Title of Designated Project

«ü©w¤uµ{¶µ¥Øªº¦WºÙ

Light Rail Transit (LRT) Extension in Tin Shui Wai Reserve Zone and Grade Separation of the LRT with Pui To Road & Tsing Lun Road in Tuen Mun [This designated project is hereinafter referred to as ¡§the Project¡¨]

 

¤Ñ¤ô³ò¹w¯d°Ï»´ÅK¤ä½u¤Î¤ÙªùªM´ç¸ô¤Î«CÅï¸ô¤§»´ÅK¬[ªÅ¸ô­y [³o«ü©w¤uµ{¶µ¥Ø¤UºÙ¡§¤uµ{¶µ¥Ø¡¨]

Nature of Designated Project
«ü©w¤uµ{¶µ¥Øªº©Ê½è

Railway, its associated stops and terminus

 

ÅK¸ô¡B¨ä¬ÛÁp¨®¯¸¤Î²×¯¸

Location of Designated Project

«ü©w¤uµ{¶µ¥Øªº¦aÂI

The location of the Project is in Tin Shui Wai Reserve Zone, junctions at Pui To Road and Tsing Lun Road in Tuen Mun as shown in Figures 1 to 4 of this Environmental Permit.

 

¦ì©ó¤Ñ¤ô³ò¹w¯d°Ï¤Î¤ÙªùªM´ç¸ô¤Î«CÅï¸ô¤§¶×±µÂI¤§¤uµ{¦aÂI¸ü©óÀô¹Ò³\¥iÃÒªº¹Ï1¦Ü4

Scale and Scope of Designated Project(s)

«ü©w¤uµ{¶µ¥Øªº³W¼Ò©M½d³ò

Tin Shui Wai Reserve Zone Extension

Operation of a 2.6 km at-grade Light Rail extension and the associated 6 new stops and 1 terminus in the Tin Shui Wai Reserve Zone

 

¤Ñ¤ô³ò¹w¯d°Ï¤ä½u

Àç¿ìªø2.6¤½¨½¤§¦a­±»´ÅK¤ä½u¤Î6­Ó¬ÛÁp·s¨®¯¸¤Î1­Ó²×¯¸

 

Grade Separation at Pui To Road in Tuen Mun

Operation of an elevated Light Rail track at the existing junctions of Pui To Road in Tuen Mun including a 1.2 km viaduct

 

¤ÙªùªM´ç¸ô¤§¬[ªÅ¸ô­y

Àç¿ì¬[ªÅ»´ÅK¸ô­y©ó²{®É¤ÙªùªM´ç¸ô¤§»´ÅK¶×±µÂI¡A¥]¬Aªø1.2¤½¨½¤§¬[ªÅ¸ô­y

 

Grade Separation at Tsing Lun Road in Tuen Mun

Operation of an elevated Light Rail track at the existing junctions at Tsing Lun Road in Tuen Mun including a 0.3km viaduct

 

«CÅï¸ô¤§¬[ªÅ¸ô­y

Àç¿ì¬[ªÅ»´ÅK¸ô­y©ó²{®É¤Ùªù«CÅï¸ô¤§»´ÅK¶×±µÂI¡A¥]¬Aªø0.3¤½¨½¤§¬[ªÅ¸ô­y


PART C (PERMIT CONDITIONS)
C³¡¡]³\¥iÃÒ±ø¥ó¡^

 

1.             General Conditions

¤@¯ë±ø¥ó

 

1.1          The Permit Holder shall ensure full compliance with all conditions of this environmental permit (the Permit). Any non-compliance may constitute a contravention of the Environmental Impact Assessment Ordinance (Cap.499) and shall be definite ground for enforcement action or permit cancellation where applicable.

³\¥iÃÒ«ù¦³¤H¥²¶·½T«O§¹¥þ²Å¦X¥»Àô¹Ò³\¥iÃÒ¡]¤UºÙ³\¥iÃÒ¡^³W©wªº¥þ³¡±ø¥ó¡C¦p¦³¤£²Å¦X¥»³\¥iÃÒªº±¡ªp¡A¥i¯àºc¦¨¹H¤Ï¡uÀô¹Ò¼vÅTµû¦ô±ø¨Ò¡]²Ä499³¹¡^¡vªº³W©w¡A¨Ã¥i«ö¾A¥Î±¡ªp§@¬°±Ä¨ú°õªk¦æ°Ê©Î¨ú¾P¨ä³\¥iÃÒªº½T¤Á²z¥Ñ¡C

 

1.2          The Permit Holder shall ensure full compliance with all legislation currently in force such as the Noise Control Ordinance (Cap.400), Air Pollution Control Ordinance (Cap.311), Water Pollution control Ordinance (Cap.358), Dumping at Sea Ordinance (Cap.466), the Waste Disposal Ordinance (Cap.354), and others. This Permit does not of itself constitute any ground of defense against any proceedings instituted under any legislation.

¥»³\¥iÃҨ䣧K°£³\¥iÃÒ«ù¦³¤H¶·²Å¦X²{¦æ¥Í®Äªºªk¨Òªº³d¥ô¡A¨Ò¦p¡u¾¸­µºÞ¨î±ø¨Ò¡]²Ä400³¹¡^¡v¡B¡uªÅ®ð¦Ã¬VºÞ¨î±ø¨Ò¡]²Ä311³¹¡^¡v¡B¡u¤ô¦Ã¬VºÞ¨î±ø¨Ò¡]²Ä358³¹¡^¡v¡B¡u®ü¤W¶É­Ëª«®Æ±ø¨Ò¡]²Ä466³¹¡^¡v¡B¡u¼oª«³B¸m±ø¨Ò¡]²Ä354³¹¡^¡v¡F¤Î¨ä¥Lªk¨Ò¡C¥»³\¥iÃÒ¥»¨­¤£¯à§@¬°¨Ì¥ô¦óªk«ß´£°_ªºªk«ßµ{§Ç¤¤§ÜÅGªº²z¥Ñ¡C

 

1.3          The Permit Holder shall make copies of this Permit together with all documents referred to in this Permit or the documents referred to in Part A of the Permit readily available at all times for inspection by the Director at all offices covered by this Permit. Any reference to the Permit shall include the documents referred to in the Permit and also the relevant documents in the Register.

³\¥iÃÒ«ù¦³¤H¶·½Æ¦L¥»³\¥iÃÒ¥H¤Î¥»³\¥iÃÒ©Ò¸üªº¦³Ãö¤å¥ó©Î¥»³\¥iÃÒA³¡©Ò«üªº©Ò¦³¤å¥óªº°Æ¥»¡A¥H¨Ñ¸pªø¥ô¦ó®É¶¡¤º¦b¥»³\¥iÃÒ©Ò²[»\ªº©Ò¦³¿ì¨Æ³B¬d¾\¡C¹ï¥»³\¥iÃÒªº¤Þ¥Î¶·¥]¬A¥»³\¥iÃÒ©Ò«üªº¤å¥ó¥H¤ÎÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B¦s©ñªº¬ÛÃö¤å¥ó¡C

 

1.4          The Permit Holder shall give a copy of this Permit to the person(s) in charge of the operation of the Project and ensure that such person(s) fully understands all conditions and all requirements incorporated in the Permit.

³\¥iÃÒ«ù¦³¤H¶·§â¥»³\¥iÃÒªº¤@¥÷½Æ¥»¥æ¤©Àç¿ì¥»¤uµ{¶µ¥Øªº­t³d¤H¡A¨Ã½T«O³o¨Ç¤H¤h§¹¥þ©ú¥Õ¥»³\¥iÃÒ¤º¸üªº©Ò¦³±ø¥ó»P³W©w¡C

 

1.5          The Permit Holder shall operate the Project in accordance with the project description in Part B of this Permit.

³\¥iÃÒ«ù¦³¤H¶·¨Ì¾Ú¥»³\¥iÃÒB³¡ªº¤uµ{¶µ¥Øªº»¡©úÀç¿ì¥»¤uµ{¶µ¥Ø¡C

 

1.6          The Permit Holder shall ensure that the Project is operated in accordance with the information and all recommendations described in the EIA Report (Register No. AEIAR-027/1999) and other relevant documents in the Register, taking full account of information or mitigation measures, and variations of work described in the previous varied Permit of the Project, or mitigation measures to be deposited with or approved by the Director. Where recommendations referred to in the documents of the Register are not expressly referred to in this Permit, such recommendations are nevertheless to be implemented unless expressly excluded or impliedly amended in this Permit.

³\¥iÃÒ«ù¦³¤H¶·½T«O¤uµ{¶µ¥ØªºÀç¿ì¿í·ÓÀôµû³ø§i¡]µn°O½s¸¹AEIAR-027/1999¡^¤º¸üªº¸ê®Æ©M«Øij¡A¤Î¦bµn°O¥U¤ºªº¨ä¥L¤å¥ó¡A¤Î¦bµn°O¥U¤ºªº¨ä¥L¤å¥ó¡A¨Ã¥R¤À¦Ò¼{¥»³\¥iÃÒ©Ò»¡©úªº¸ê®Æ©Î½w¸Ñ±¹¬I©M¦b¦­«eªº¤uµ{¶µ¥Ø§ó§ï³\¥iÃÒ¤º»¡©úªº¤uµ{§ó§ï¡A©Î¥Ñ³\¥iÃÒ±ø¥ó©Ò¾É­P¶·¦s©ñ©ó©Î¥Ñ¸pªø®Ö·Çªº½w¸Ñ±¹¬I¡C·í¦bµn°O¥U¤º©Ò¸ü«Øij¨Ã¨S¦³©ú½T¦b¥»³\¥iÃÒ¤º«ü¥X¡A¦¹µ¥«Øij¨ÃÀ³¦P¼Ë¹ê¬I¡C°£«D¡A¦¹µ¥«Øij¤w¦b¥»³\¥iµý¤º¤w©ú½T«ü¥X¨Ã¤£¥]¬A¤º©Î©ú½T­×­q¡C

 

1.7          All submissions approved by the Director, all submissions deposited without comments by the Director, or all submissions rectified in accordance with comments by the Director under this permit shall be construed as part of the permit conditions described in Part C of this Permit. Any variation of the submissions shall be approved by the Director in writing or as prescribed in the relevant permit conditions. Any non-compliance with the submissions may constitute a contravention of the Environmental Impact Assessment Ordinance (Cap.499).  All submissions or their variations shall be verified and certified by the Independent Environmental Checker (IEC), with at least 7 years experience in environmental monitoring and auditing or environmental management, before submitting to the Director under this Permit.

©Ò¦³®Ú¾Ú¥»³\¥iÃÒ³W©w´£¤å¸g¸pªø§å­ãªº¤å¥ó¡B¸pªø¨S¦³·N¨£ªº¤å¥ó©Î¤w¾É±q¸pªø¸g·N¨£­×­qªº¤å¥ó§¡¬°¥»³\¥iÃÒC³¡©Ò­z³\¥iÃÒ±ø¥óªº²Õ¦¨³¡¤À¡C¹ï¤å¥ó©Ò§@ªº¥ô¦óÅܧóÀ³¸g¸pªø®Ñ­±©Î¨Ì·Ó¬ÛÃö³\¥iÃÒ±ø¥ó³W©wªº¨ä¥L¤è¦¡§å­ã¡C»P¤å¥óªº¥ô¦ó¤£²Å±N³Qµø¬°¹H¤ÏÀô¹Ò¼vÅT±ø¨Ò¡]²Ä499³¹¡^¡C¦b´£¥æ¤å¥ó¥Ó½Ð§å­ã«e¡A©Ò§@ªºÅܧóÀ³¥Ñ¨ã¦³¤C¦~Àô¹ÒºÊ¹î»P¼f®Ö©ÎÀô¹ÒºÞ²z¸gÅ窺¿W¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡A½T»{¨ä²Å¦XÀô¹Ò¼vÅTµû¦ô³ø§i¤º©Ò¸üªº¸ê®Æ©M«Øij¡C

 

1.8          The Permit Holder shall release all finalized submissions, as required under this Permit, to the public by depositing copies in the Environmental Impact Assessment Ordinance Register Office, or in any other places as specified by the Director, or by any other means as specified by the Director for public inspection. For this purpose, the Permit Holder shall provide sufficient copies of the submissions.

³\¥iÃÒ«ù¦³¤H¶·®Ú¾Ú¸pªø­n¨D¡A¤½¶}©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó©w½Zµ¹¤½²³¤H¤h¬d¾\¡A¤èªk¬O±N¦³Ãö¤å¥ó°Æ¥»¦s©ñ©óÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B©Î¸pªø©Ò«ü©wªº¥ô¦ó¨ä¥L¦a¤è©Î¤¬Ápºôºô¯¸¡A©Î±Ä¨ú«ü©wªº¥ô¦ó¨ä¥L¤èªk¡A¥H¨Ñ¤½²³¬d¾\¡C¬°¦¹¡A³\¥iÃÒ«ù¦³¤H¶·´£¨Ñ¨¬°÷¼Æ¶qªº¤å¥ó°Æ¥»¡C

 

1.9          All submissions to the Director required under this Permit shall be delivered either in person or by registered mail to the Environmental Impact Assessment Ordinance¡¦s Register Office at 27/F, Southern Centre, 130 Hennessy Road, Wanchai, Hong Kong.

¥»³\¥iÃÒ­n¨D´£¥æ¸pªøªº©Ò¦³¤å¥óÀ³¥Ñ±M¤H°e¹F©Î¥H±¾¸¹¶l±H¤è¦¡¡A°e¥æ­»´äÆW¥J°a¥§¸Ö¹D130¸¹­×¹y¤¤¤ß27¼ÓÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B¡C

 

2.             Measures during Operation of the Project

¶µ¥ØÀç¹B´Á¶¡±Ä¨úªº±¹¬I

 

2.1       The Permit Holder shall properly implement and maintain the Landscape Master Plan as approved under the Permit No. EP-042/2000 or under subsequent varied Permit. The Plan shall show the detailed landscape proposals during the operation stage of the Project, and shall include an implementation programme of landscape works. All measures recommended in the approved Plan shall be fully implemented in accordance with the details and time schedule set out in the Plan.

³\¥iÃÒ«ù¦³¤H¶·§´µ½°õ¦æ¤Î«O¾i¦b³\¥iÃÒ½s¸¹EP-042/2000©Î¨ä«á§ó§ï³\¥iÃÒ¤U§å­ãªº ´ºÆ[³]­pÁ`¹Ï¡CÁ`¹Ï¶·»¡©úÀç¹B´Á¤ºªº¸Ô²Ó´ºÆ[«Øij¡A¨ÃÀ³¥]¬A´ºÆ[¤uµ{¹ê¬I­p¹º¡C¤w§å­ã­p¹ºÁ`¹Ï¤º¸üªº©Ò¦³«Øij±¹¬IÀ³®Ú¾ÚÁ`¹Ï¤º³W©wªº²Ó¸`¤Î®É¶¡ªí¡A¥þ­±¹ê¬I¡C

 

2.2       The Permit Holder shall properly implement and maintain the environmental mitigation measures to the rectifier station (ie. R16 refers to in the EIA Report) and design of the associated ventilation as approved under the Permit No. EP-042/2000 or under subsequent varied Permit.

³\¥iÃÒ«ù¦³¤H¶·§´µ½°õ¦æ¤Î«O¾i¦b³\¥iÃÒ½s¸¹EP-042/2000©Î¨ä«á§ó§ï³\¥iÃÒ¤U§å­ãªº¹ï¾ã¬y¯¸¡]§YR16¡A¨£Àô¹Ò¼vÅTµû¦ô³ø§i¡^±Ä¨úªºÀô¹Ò½w¸Ñ±¹¬I¥H¤Î¦³Ãö³q­·¨t²Îªº³]­p¡C

      

2.3       The Permit Holder shall properly implement and maintain the Tree Planting Plan as approved under the Permit No. EP-042/2000 or under subsequent varied Permit. The Plan shall show the detailed tree planting works to be carried out within the Tuen Mun Town Park to compensate for loss of trees within the vicinity due to the Project. All measures recommended in the approved Plan shall be fully implemented in accordance with the details and time schedule set out in the Plan.

³\¥iÃÒ«ù¦³¤H¶·§´µ½°õ¦æ¤Î«O¾i¦b³\¥iÃÒ½s¸¹EP-042/2000©Î¨ä«á§ó§ï³\¥iÃÒ¤U§å­ãªº´Ó¾ð¹Ï¡C¹Ï«h¶·Åã¥Ü±N¦b¤Ùªù¥«Âí¤½¶é¤º¶i¦æªº´Ó¾ð¤uµ{¸Ô±¡¡A¥H¸ÉÀv¶i¦æ¤uµ{¶µ¥Ø¹ïªþªñ¦a¤è³y¦¨ªº¾ð¤ì·l¥¢¡CÀò§å­ãªº¹Ï«h«Øijªº©Ò¦³±¹¬I¡A¶·«ö·Ó¹Ï«h©Ò¸ü¸Ô±¡¤Î®É¶¡ªí§¹¥þ°õ¦æ¡C

 

2.4       A solid parapet wall of 1.4 meter high above the rail head shall be installed along the full extent of the viaduct at the grade separation in Lam Tei as shown in Figure 3. Absorptive lining shall be installed on the parapet wall on the sides facing the rail tracks. The Permit Holder shall properly implement and maintain the design of the parapet wall with the absorptive lining as approved under the Permit No. EP-042/2000 or under subsequent varied Permit.

¦b¹Ï3©Ò¥Ü¦ì©óÂŦaªº¾ã¬q»´ÅK¬[ªÅ¸ô­y¡A¶·³]¸m°ª©ó­yÀY1.4¦Ìªº¹ê¤ßÅ@Àð¡A¨Ã¶·¦b´Â¸ô­y¤è¦VªºÅ@Àð³]¸m§l­µÅ¨¼h¡C³\¥iÃÒ«ù¦³¤H¶·µ½°õ¦æ¤Î«O¾i¦b³\¥iÃÒ½s¸¹EP-042/2000©Î¨ä«á§ó§ï³\¥iÃÒ¤U§å­ãªº³]¦³§l­µÅ¨¼hªºÅ@Àð³]­p¡C

 

2.5       The operation of the Project shall meet the following specifications

     ¥»¤uµ{¶µ¥ØªºÀç¿ì¶·º¡¨¬¤U¦C³W©w¡G

 

(a)           re-radiated noise from viaduct structure is at least 10dB(A) below the noise criteria of 65dB(A) Lmax at 25m, at 50kph; and

°ª¬[µ²ºcªº¦A¿ç®g¾¸­µ³Ì¤Ö¤ñ25m¡A50kph±ø¥ó¤U65dB(A)Lmax¾¸­µ¼Ð·Ç§C10dB(A)¡F¥H¤Î

(b)           noise level at 2m from the transformer bays in the rectifier will be less than 66dB(A).

¾ã¬y¯¸¤º¶ZÅÜÀ£¾¹¦ì2¦Ì³Bªº¾¸­µ¤ô¥­¤Ö©ó66dB(A)¡C

 

2.6       Measures described in Appendix A to mitigate environmental impacts from run-off and drainage shall be implemented throughout the operation period.

³\¥iÃÒ«ù¦³¤H¶·¹ê¬Iªþ¿ýA³W©wªº±¹¬I¡A¥H´î»´Àç¹B´Á¶¡¡A®|¬y¤Î±Æ¤ôªº¼vÅT¡C

 

2.7       Any change to the design or measures relevant to the operation of the Project shall be justified and certified by the IEC with at least 7 years experience in environmental monitoring and auditing or environmental management before submission to the Director for approval.

¹ï©ó¦³Ãö¤uµ{¶µ¥Ø¹B§@´Á¶¡ªº³]­p©Î±¹¬I©Ò§@ªº¥ô¦óÅܧóÀ³¦b´£¥æ¸pªø¥Ó½Ð¼f§å«e¡A¶·¥Ñ¨ã¦³¤C¦~Àô¹ÒºÊ¹î»P¼f®Ö©ÎÀô¹ÒºÞ²z¸gÅ窺¿W¥ßÀô¹Ò¬d®Ö¤H´£¥X¨ã¥R¤À²z¥Ñ¡A¨Ã¥Ñ¿W¥ßÀô¹Ò¬d®Ö¤H»{ÃÒ¡C

 

 

 

 

 

Notes:

µù ¡G

 

1.              This Permit consists of three parts, namely, Part A (Main Permit), Part B (Description of Designated Project) and Part C (Permit Conditions). Any person relying on this permit should obtain independent legal advice on the legal implications under the Ordinance, and the following notes are for general information only.

¥»³\¥iÃÒ¦@¦³3³¡¡A§YA³¡(³\¥iÃÒ¥D­n³¡¤À)¡FB³¡(«ü©w¤uµ{¶µ¥Øªº»¡©ú)¤ÎC³¡(³\¥iÃÒ±ø¥ó)¡C¥ô¦ó´©¤Þ¥»³\¥iÃÒªº¤H¤h¶·´N±ø¨Òªºªk«ß§t·N¼x¸ß¿W¥ßªk«ß·N¨£¡A¤U­zµù¸Ñ¥u¨Ñ¤@¯ë°Ñ¦Ò¤§¥Î¡C

 

2.              If there is a breach of any conditions of this Permit, the Director or his authorized officer may, with the consent of the Secretary for the Environment, order the cessation of associated work until the remedial action is taken in respect of the resultant environmental damage, and in that case the Permit Holder shall not carry out any associated works without the permission of the Director or his authorized officer.

¦p¹H¤Ï¥»³\¥iÃÒªº¥ô¦ó±ø¥ó¡A¸pªø©ÎÀò±ÂÅv¤H­û¦b¼x±oÀô¹Ò§½§½ªøªº¦P·N«á¡A¥i°Ç¥O°±¤î¬ÛÃö¤uµ{¡Aª½¦Ü³\¥iÃÒ«ù¦³¤H¬°©Ò³y¦¨ªºÀô¹Ò·l®`±Ä¨ú¸É±Ï¦æ°Ê¬°¤î¡C¦b¦¹±¡ªp¤U¡A³\¥iÃÒ«ù¦³¤H¦b¥¼¸g¸pªø©ÎÀò¨ä±ÂÅv¤H­û¦P·N¡A¤£±o¶i¦æ¥ô¦ó¬ÛÃö¤uµ{¡C

 

3.              The Permit Holder may apply under Section 13 of the Environmental Impact Assessment Ordinance (the ¡§Ordinance¡¨) to the Director for a variation of the conditions of this Permit.  The Permit Holder shall replace the original permit displayed on the Project site by the amended permit.

³\¥iÃÒ«ù¦³¤H¥i®Ú¾ÚÀô¹Ò¼vÅTµû¦ô±ø¨Ò(¡§±ø¨Ò¡¨)²Ä13±øªº³W©w¡A¦V¸pªø¥Ó½Ð§ó§ï¥»Àô¹Ò³\¥iÃÒªº±ø¥ó¡C³\¥iÃÒ«ù¦³¤H¶·§â¸g­×§ïªº³\¥iÃÒ´À´«¦b¤uµ{¶µ¥Ø¤u¦a¤º®i¥Üªº­ì¦³³\¥iÃÒ¡C

 

4.              A person who assumes the responsibility for the whole or a part of the Project may, before he assumes responsibility of the Project, apply under Section 12 of the Ordinance to the Director for a further environmental permit.

©Ó¾á¤uµ{¶µ¥Ø¾ã¶µ©Î³¡¤À¤uµ{ªº­t³d¤H¡A¦b©Ó¾á³d¥ô¤§«e¡A¥i®Ú¾Ú±ø¨Ò²Ä12±ø¦V¸pªø¥Ó½Ð·sªºÀô¹Ò³\¥iÃÒ¡C

 

5.              Under Section 14 of the Ordinance, the Director may with the consent of the Secretary for the Environment, suspend, vary or cancel this Permit. The suspended, varied or cancelled Permit shall be removed from display at the Project site.

®Ú¾Ú±ø¨Ò²Ä14±ø¡A¸pªø¥i¦bÀô¹Ò§½§½ªøªº¦P·N¤U¼È®É¦Q¾P¡B§ó§ï©Î¨ú®ø¥»Àô¹Ò³\¥iÃÒ¡C¾D¼È®É¦Q¾P¡B§ó§ï©Î¨ú®øªºÀô¹Ò³\¥iÃÒ¡A¥²¶·±q¤uµ{¶µ¥Ø¤u¦a°£¤U¡A¤£¦A®i¥Ü¡C

 

6.              If this Permit is cancelled or surrendered during operation of the Project, another environmental permit must be obtained under the Ordinance before the Project could be continued. It is an offence under Section 26 (1) of the Ordinance to operate a designated project listed in Schedule 2 of the Ordinance without a valid environmental permit.

¦pªG¥»³\¥iÃÒ¦b¤uµ{¶µ¥ØÀç¿ì´Á¶¡¨ú®ø©Î¥æ¦^¡A«h¦bÄ~ÄòÀç¿ì¤uµ{¶µ¥Ø¤§«e¡A¥²¶·¥ý®Ú¾Ú±ø¨Ò³W©w¨ú±o¥t¤@¥÷Àô¹Ò³\¥iÃÒ¡C®Ú¾Ú±ø¨Ò²Ä26(1)±ø¡A¥ô¦ó¤H¦b¨S¦³¦³®ÄÀô¹Ò³\¥iÃÒªº±¡ªp¤UÀç¿ì±ø¨Òªþªí2©Ò¦C©úªº«ü©w¤uµ{¶µ¥Ø¡A§YÄݥǸo¡C

 

7.              Any person who operates the Project contrary to the conditions in the Permit, and is convicted of an offence under the Ordinance, is liable :

¥ô¦ó¤H¦b¹H¤Ï¥»³\¥iÃÒªº±ø¥ó¤UÀç¿ì¤uµ{¶µ¥Ø©Î¸Ñ°£¤uµ{¶µ¥Ø¡A¨Ã¥B®Ú¾ÚÀôµû±ø¨Ò©w¸o¡A§Y¥i¾D¨ü ¡X

 

(i)     on a first conviction on indictment to a fine of $2 million and to imprisonment for 6 months;

¤@¸g´`¤½¶Dµ{§Ç­º¦¸©w¸o¡A¥i³B»@´Ú200¸U¤¸¤ÎºÊ¸T6­Ó¤ë¡F

(ii)    on a second or subsequent conviction on indictment to a fine of $5 million and to imprisonment for 2 years;

¤@¸g´`¤½¶Dµ{§Ç²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú500¸U¤¸¤ÎºÊ¸T2¦~¡F

(iii)    on a first summary conviction to a fine at level 6 and to imprisonment for 6 months;

¤@¸g´`²©öµ{§Ç­º¦¸©w¸o¡A¥i³B²Ä6¯Å»@´Ú¤ÎºÊ¸T6­Ó¤ë¡F

(iv)   on a second or subsequent summary conviction to a fine of $1 million and to imprisonment for 1 year; and

¤@¸g´`²©öµ{§Ç²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú100¸U¤¸¤ÎºÊ¸T1¦~¡F¤Î

 

(v)    in any case where the offence is of a continuing nature, the court or magistrate may impose a fine of $10,000 for each day on which he is satisfied the offence continued.

¦b¥ô¦ó±¡ªp¤U¦p¸Ó¸o¦æÄÝ«ùÄò©Ê½è¡Aªk°|©Îµô§P©x¥i´N¨ä«H¯Ç¸Ó¸o¦æ«ùÄòªº¨C¤@¤Ñ¥t³B»@´Ú10,000¤¸¡C

 

8.              The Permit Holder may appeal against any condition of this Permit under Section 17 of the Ordinance within 30 days of receipt of this Permit.

³\¥iÃÒ«ù¦³¤H¥i¦b±µÀò¥»³\¥iÃÒ«á30¤Ñ¤º¡A®Ú¾Ú±ø¨Ò²Ä17±ø´N¥»³\¥iÃÒªº¥ô¦ó±ø¥ó´£¥X¤W¶D¡C

 

9.              The Notes are for general reference only and that the Permit Holder should refer to the EIA Ordinance for details and seek independent legal advice.

¤W­zµù¸Ñ¥u¨Ñ¤@¯ë°Ñ¦Ò¥Î¡A±ýª¾¦³Ãö¸Ô±¡¡A³\¥iÃÒ«ù¦³¤H¶·°Ñ¾\Àôµû±ø¨Ò¤Î¼x¸ß¿W¥ßªk«ß·N¨£¡C

 

 

Environmental Permit No.FEP-02/042/2000/E

Àô¹Ò³\¥iÃÒ½s¸¹  FEP-02/042/2000/E


Appendix A

Measures to Mitigate Environmental Impacts from Site Runoff and Drainage during Operation

ªþ¿ýA

½w¸ÑÀç¹B´Á¶¡¡A®|¬y¤Î±Æ¤ôÀô¹Ò¼vÅTªº±¹¬I

 

To mitigate the environmental impacts from site runoff and drainage during the operational phase, the following shall be implemented:

À³¹ê¬I¤U¦C±¹¬I¡A¥H½w¸ÑÀç¹B´Á¤º¦]¦a½L®|¬y¤Î±Æ¤ô³y¦¨ªºÀô¹Ò¼vÅT¡G

 

(a)      A surface water drainage system shall be provided to collect the track runoff.  Where oil and lubricating fluids can be spilt, the tract drainage channels discharge shall pass through oil/grit interceptors/chambers, or a sub-soil drainage system to remove oil, grease and sediment before being pumped to the public stormwater drainage system.

À³´£¨Ñ¦a­±¤ô±Æ¤ô¨t²Î¥H¦¬¶°ÅK­y®|¬y¡C¦bªo¦Ã¤Î¼í·Æ²G¥i¯à¥X²{¥~·¸ªº¦a¤è¡AÅK­y±Æ¤ô´ë±Æ¥Xªº¦Ã¤ôÀ³¦b¬¦¤J¤½¦@«B¤ô±Æ¤ô¨t²Î«e¡A¬y¸gªo¦Ã/¬âÄtºI¬y¤«/¦À¡A©Î¦a¤U±Æ¤ô¨t²Î¡A¥H²M°£ªo¦Ã¡Bªo¯×¤Î¨I¿nª«¡C

 

(b)      Silt traps and oil interceptors shall be cleaned and maintained regularly to ensure proper functioning and efficient operation.

²Jªd¦¬¶°¾¹¤Îªo¦ÃºI¬y¤«À³©w´Á²M¼ä¤Î«O¾i¡A¥H½T«O¥¿±`¾Þ§@¤Î®Ä²v¡C

 

(c)      Oily contents of the oil interceptors shall be transferred to an appropriate disposal facility, or to be collected for reuse, if possible.

ªo¦ÃºI¬y¤«¤º¦¬¶°ªºªo¦ÃÀ³Âಾ¨ì¾A·íªº³B¸m³]¬I©Î¦b¥i¯à®É¦^¦¬§Q¥Î¡C