Environmental Permit No. FEP-05/347/2009/A
Àô¹Ò³\¥iÃÒ½s¸¹ FEP-05/347/2009/A
ENVIRONMENTAL
IMPACT ASSESSMENT ORDINANCE
(CHAPTER 499)
Sections 10 & 12
Àô¹Ò¼vÅTµû¦ô±ø¨Ò
(²Ä499³¹)
²Ä10¤Î12±ø
ENVIRONMENTAL PERMIT
TO CONSTRUCT A DESIGNATED PROJECT
«Ø³y«ü©w¤uµ{¶µ¥ØªºÀô¹Ò³\¥iÃÒ
A³¡ (³\¥iÃÒ¥Dn³¡¤À)
Pursuant to
Sections 10 and 12 of the Environmental Impact Assessment Ordinance (EIAO), the
Director of Environmental Protection (the Director) grants this environmental
permit to China
International Water & Electric Corporation (hereinafter
referred to as the ¡§Permit Holder¡¨) to construct the designated project
described in Part B subject to the conditions specified in
Part C. The issue of this environmental permit is based on
the documents, approvals or permissions described below:
®Ú¾Ú¡mÀô¹Ò¼vÅTµû¦ô±ø¨Ò¡n(Àôµû±ø¨Ò) ²Ä10¤Î12±øªº³W©w¡AÀô¹Ò«OÅ@¸p¸pªø(¸pªø)±N¥»Àô¹Ò³\¥iÃҧ天¤¤°ê¤ô§Q¹q¤O¹ï¥~¤½¥q(¤UºÙ¡§³\¥iÃÒ«ù¦³¤H¡¨)¥H«Ø³yB³¡©Ò»¡©úªº«ü©w¤uµ{¶µ¥Ø¡A¦ý¶·¿í¦uC³¡©Ò¦C©úªº±ø¥ó¡C¥»Àô¹Ò³\¥iÃÒ¬O¨Ì¾Ú¤U¦C¤å¥ó¡B§åã©Î³\¥i¦Óñµo¡G
|
Application No. ¥Ó½Ð®Ñ½s¸¹¡G |
FEP-139/2012 |
||
|
Document in the
Register: µn°O¥U¤Wªº¤å¥ó¡G |
(1)
Construction of a Secondary Boundary Fence and
new sections of Primary Boundary Fence and -
Environmental Impact Assessment (Volume 1 and
Volume 2) [Hereinafter referred to as the ¡§EIA Report¡¨] -
Environmental Monitoring & Audit Manual
[Hereinafter referred to as the ¡§EM&A Manual¡¨] -
Environmental Impact Assessment - Executive
Summary [Hereinafter referred to as the ¡§EIA Executive Summary¡¨] (Register
No. AEIAR-136/2009) »²§UÃä¬É³òºô¤Î¥D³òºô©MÃä¬É¨µÅÞ³q¸ô·s¬q«Ø³y¤uµ{ -
Àô¹Ò¼vÅTµû¦ô³ø§i
(²Ä¤@¥U¤Î²Ä¤G¥U) [¤UºÙ ¡§Àôµû³ø§i¡¨] -
Àô¹ÒºÊ¹î¤Î¼f®Ö¤â¥U
[¤UºÙ ¡§ÀôºÊ¤â¥U¡¨] -
Àô¹Ò¼vÅTµû¦ô³ø§i¦æ¬FºKn
[¤UºÙ ¡§ÀôµûºKn¡¨] (µn°O¥UÀɸ¹¡G AEIAR-136/2009) (2)
The Director¡¦s letter of approval of the EIA
report dated 8 April 2009 (Reference: (23) in EP2/G/Q/ ¸pªø©ó2009¦~4¤ë8¤éµo¥X§åãÀôµû³ø§iªº«H¥ó¡]ÀÉ®×½s¸¹: (23) in EP2/G/Q/ (3)
Application for Environmental Permit submitted
on 11 May 2009 (Application No. AEP-347/2009) ©ó2009¦~5¤ë11¤é´£¥æªºÀô¹Ò³\¥iÃÒ¥Ó½Ð
(¥Ó½Ð®Ñ½s¸¹ AEP-347/2009) (4)
Environmental
Permit (No. EP-347/2009) issued on 5 June 2009 ©ó (5)
Application for
Variation of an Environmental Permit submitted on 24 May 2010 (Application No.
VEP-314/2010) ©ó2010¦~5¤ë24¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽР(¥Ó½Ð®Ñ½s¸¹: VEP-314/2010) (6)Environmental Permit (No. EP-347/2009/A) issued on 9 June 2010 ©ó2010¦~6¤ë9¤éñµoªºÀô¹Ò³\¥iÃÒ (½s¸¹EP-347/2009/A) (7)Application for Further Environmental Permit submitted on 13 August 2010 (Application No. FEP-112/2010) ©ó2010¦~8¤ë13¤é´£¥æªº·sªºÀô¹Ò³\¥iÃҥӽР(¥Ó½Ð®Ñ½s¸¹: FEP-112/2010) (8)Further Environmental Permit (No. FEP-04/347/2009/A) issued on 7 September 2010 ©ó (9)Application for Further Environmental Permit submitted on 17 July 2012 (Application No. FEP-139/2012) ©ó |
||
10 August 2012 |
|
|
||
Date ¤é´Á |
(WONG Hon-meng) Principal Environmental Protection Officer (Strategic
Assessment) for Director of Environmental Protection Àô¹Ò«OÅ@¸p¸pªø (º®uÀô¹Ò«OÅ@¥D¥ô(µ¦²¤µû¦ô) ¶Àº~©ú ¥N¦æ) |
|||
PART B (DESCRIPTIONS OF
DESIGNATED PROJECT)
B³¡ («ü©w¤uµ{¶µ¥Øªº»¡©ú)
Hereunder is the description of the designated project mentioned in Part A of this environmental permit (hereinafter referred to as the ¡§Permit¡¨):
¤U¦C爲¥»Àô¹Ò³\¥iÃÒ(¤UºÙ¡§³\¥iÃÒ¡¨)A³¡©Ò´£zªº«ü©w¤uµ{¶µ¥Øªº»¡©ú:
Title of
Designated Project «ü©w¤uµ{¶µ¥Øªº¦WºÙ |
Construction
of a Secondary Boundary Fence and New Sections of Primary Boundary Fence and
Boundary Patrol Road (Section 3- From Ng Tung River to Ping Yuen River and
from Pak Fu Shan to Lin Ma Hang) »²§UÃä¬É³òºô¤Î¥D³òºô©MÃä¬É¨µÅÞ³q¸ô·s¬q«Ø³y¤uµ{(¥Ñ±ï®äªe¦Ü¥ìªe©M¥Ñ¥Õªê¤s¦Ü½¬³Â§|§ø) [This
designated project is hereinafter referred to as ¡§the Project¡¨.] [³o«ü©w¤uµ{¶µ¥Ø¤UºÙ¡§¤uµ{¶µ¥Ø¡¨] |
Nature of
Designated Project |
Earthworks
and building works along the existing boundary patrol road from Ng Tung River
to ¥Ñ±ï®äªe¦Ü¥ìªe©M¥Ñ¥Õªê¤s¦Ü½¬³Â§|ªu²{¦³ªºÃä¬É¨µÅÞ³q¸ô¶i¦æ¤g¤ì¤u¨Æ¤Î«Ø¿v¤uµ{ |
Location of
Designated Project «ü©w¤uµ{¶µ¥Øªº¦aÂI |
From
Ng Tung River to ¥Ñ±ï®äªe¦Ü¥ìªe©M¥Ñ¥Õªê¤s¦Ü½¬³Â§| Figure 1
attached to this Permit shows the location of the Project. ¤uµ{¶µ¥Øªº¦ì¸m¸ü©ó¥»³\¥iÃÒªºªþ¹Ï1¡C |
Scale and Scope
of Designated Project(s) «ü©w¤uµ{¶µ¥Øªº³W¼Ò©M½d³ò |
The
project scope of this section is described below: Section 3 ¡V Ng Tung River to (i)
To erect a Secondary Boundary Fence (SBF) along
the existing Boundary Patrol Road (BPR) except the sections to the north of
Pak Fu Shan and northwest of Lin Ma Hang Village; (ii)
To construct new sections of the BPR along the
Shenzhen River side to the northwest of Lin Ma Hang Village without
necessitating river training; (iii)
To erect a new Primary Boundary Fence (PBF)
with the sensor alarm system and a SBF along the northern and southern sides
of the new sections of BPR respectively; (iv)
To remove the original PBF and the sensor alarm
system thereon along the existing BPR near Pak Fu Shan and Lin Ma Hang
Village; and (v)
To remove the existing checkpoints at Sha Ling
and Ping Che. ¦¹³¡¥÷¤uµ{¶µ¥Øªº½d³ò¦p¤U¡G ²Ä¤T³¡¥÷ - ¥Ñ±ï®äªe¦Ü¥ìªe©M¥Ñ¥Õªê¤s¦Ü½¬³Â§| (i)
°£¥Õªê¤s¥_±¤Î½¬³Â§|§ø¦è¥_±¤@¬q¥~¡A¦b²{¦³ªºÃä¬É¨µÅÞ³q¸ô³]¸m»²§UÃä¬É³òºô¡F (ii)
¦b¤£»Ý¶i¦æªe¹D§ïµ½¤uµ{ªº±¡ªp¤U¡A¦b½¬³Â§|§ø¦è¥_±ªu²`¦`ªeÃä«Ø³yÃä¬É¨µÅÞ³q¸ô·s¬q¡F (iii)
ªuÃä¬É¨µÅÞ³q¸ô·s¬qªº¥_±³]¸m¸Ë¦³·PÀ³Äµ³ø¨t²Îªº·s¥D³òºô¡A¥H¤Îªu¸Ó³q¸ô«n½t³]¸m»²§UÃä¬É³òºô¡F (iv)
ÀH«á¦b¦ì©ó¥Õªê¤s¤Î½¬³Â§|§ø¥H«n²{¦³ªºÃä¬É¨µÅÞ³q¸ô©î°£ì¨Óªº¥DÃä¬É³òºô¤Î·PÀ³Äµ³ø¨t²Î¡F¤Î (v)
©î°£²{®É¦ì©ó¨FÀ¤Î©Wà|ªºÀˬd¯¸¡C |
C³¡ (³\¥iÃÒ±ø¥ó)
1.
General Conditions
¤@¯ë±ø¥ó
1.1 The Permit Holder and any person working on
the Project shall comply with all conditions set out in this Permit. Any
non-compliance by any person may constitute a contravention of the
Environmental Impact Assessment Ordinance (EIAO) (Cap. 499) and may become the
subject of appropriate action being taken under the EIAO.
³\¥iÃÒ«ù¦³¤H¤Î¥ô¦ó±q¨Æ¤uµ{¶µ¥Øªº¤H¤h¥²¶·²Å¦X¥»³\¥iÃÒ¸ü¦Cªº¥þ³¡±ø¥ó¡C¥ô¦ó¤H¤h¦p¦³¤£²Å¦X¥»³\¥iÃÒªº±¡ªp¡A¥i¯à¹H¤ÏÀô¹Ò¼vÅTµû¦ô±ø¨Ò (¡uÀôµû±ø¨Ò¡v) (²Ä499³¹) ªº³W©w¡A¦Ó·í§½¥i®Ú¾Ú±ø¨Ò±Ä¨ú¾A·í¦æ°Ê¡C
1.2
The Permit Holder shall ensure full compliance with
all legislation from time to time in force including, without limitation to,
the Noise Control Ordinance (Cap. 400), Air Pollution Control Ordinance (Cap.
311), Water Pollution Control Ordinance (Cap. 358), and Waste Disposal
Ordinance (Cap. 354). This Permit does not of itself constitute any ground of
defence against any proceedings instituted under any legislation or imply any
approval under any legislation.
³\¥iÃÒ«ù¦³¤H¶·¸g±`½T«O§¹¥þ²Å¦X²{¦æªk¨Òªº³W©w¡A¥]¬A¦ý¤£©ó¾¸µºÞ¨î±ø¨Ò(²Ä400³¹)¡FªÅ®ð¦Ã¬VºÞ¨î±ø¨Ò(²Ä311³¹)¡F¤ô¦Ã¬VºÞ¨î±ø¨Ò(²Ä358³¹)¡F¥H¤Î¼oª«³B¸m±ø¨Ò(²Ä354³¹)¡C¥»³\¥iÃÒ¥»¨¤£·|´N®Ú¾Ú¥ô¦óªk¨Ò´£°_ªºªk«ßµ{¦¡ºc¦¨¥ô¦ó§ÜÅG²z¥Ñ¡A©Î®Ú¾Ú¥ô¦óªk¨ÒÀq¥Ü¥ô¦ó§åã¡C
1.3
The Permit Holder shall make copies of this Permit
together with all documents referred to in this Permit and the documents
referred to in Part A of the Permit readily available at
all times for inspection by the Director or his authorised officers at all
sites/offices covered by this Permit. Any reference to the Permit shall include
all documents referred to in the Permit and also the relevant documents in the
Register.
³\¥iÃÒ«ù¦³¤H¶·¦L»s¥»³\¥iÃÒªº½Æ¥»¡A³s¦P¥»³\¥iÃÒ©Òzªº©Ò¦³¤å¥ó¤Î¥»³\¥iÃÒA³¡©Òz¤å¥ó¡A¥H¨Ñ¸pªø©ÎÀò±ÂÅv¤Hû¥ô¦ó®É¶¡¤º¦b¥»³\¥iÃÒ©Ò²[»\ªº©Ò¦³¤u¦a / ¿ì¨Æ³B¬d¾\¡C¤Z´£z¥»³\¥iÃÒ¡A¶·¥]¬A¥»³\¥iÃÒ©Òzªº©Ò¦³¤å¥ó¤Îµn°O¥U¤ºªº¬ÛÃö¤å¥ó¡C
1.4
The Permit Holder shall give a copy of this Permit to
the person(s) in charge of the site(s) and ensure that such person(s) fully
understands all conditions and all requirements incorporated in the Permit. The
site(s) refers to site(s) of construction of the Project and shall mean the
same hereafter.
³\¥iÃÒ«ù¦³¤H¶·§â¥»³\¥iÃÒªº½Æ¥»¥æ¤©¦³Ãö¤u¦aªºt³d¤H¡A¨Ã½T«O³o¨Ç¤H¤h§¹¥þ©ú¥Õ¥»³\¥iÃÒªº©Ò¦³±ø¥ó»P³W©w¡C¤u¦a¬O«ü«Ø³y¤uµ{¶µ¥Øªº¤u¦a¡A¤U¤å©Ò´£¤Îªº¤u¦a¥çÄݦP¤@·N«ä¡C
1.5
The Permit Holder shall display conspicuously a copy
of this Permit on the Project site(s) at all vehicular site entrances/exits or
at a convenient location for public¡¦s information at all times. The Permit
Holder shall ensure that the most updated information about the Permit,
including any amended Permit, is displayed at such locations. If the
Permit Holder surrenders a part or the whole of the Permit, the notice he sends
to the Director shall also be displayed at the same locations as the original
Permit. The suspended, varied or cancelled Permit shall be removed from
display at the Project site(s).
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Øªº¤u¦aªº©Ò¦³¨®½ø¶i¥X¤f©Î¤@³B¤è«K¦aÂI¡AÅã²´¦a®i¥Ü¥»³\¥iÃÒªº½Æ¥»¡A¥H¨Ñ¤½衆¦b¥ô¦ó®É¶¡¤º¾\Äý¡C³\¥iÃÒ«ù¦³¤H¶·½T«O¦b³o¨Ç¦aÂI®i¥ÜÃö©ó¥»³\¥iÃÒ (¥]¬A¥ô¦ó¸g×qªº³\¥iÃÒ) ªº³Ì·s¸ê®Æ¡C³\¥iÃÒ«ù¦³¤H¦p¥æ¦^³\¥iÃÒªº³¡¤À©Î¥þ³¡¡A¥²¶·§â¨ä°e¥æ¸pªøªº³qª¾®Ñ¡A¦b³Æ¦³ì¦³³\¥iÃÒªº¬Û¦P¦aÂI®i¥Ü¡C¾D¼È®É¦Q¾P¡B§ó§ï©Î¨ú®øªº³\¥iÃÒ¥²¶·±q¤uµ{¶µ¥Øªº¤u¦a°£¤U¡A¤£¦A®i¥Ü¡C
1.6
The Permit Holder shall
construct the Project in accordance with the project description in Part B of this Permit.
³\¥iÃÒ«ù¦³¤H¶·¨Ì¾Ú¥»³\¥iÃÒB³¡ªº¤uµ{¶µ¥Ø»¡©ú¡A«Ø³y¤uµ{¶µ¥Ø¡C
1.7
The Permit
Holder shall ensure that the Project is designed and constructed in accordance
with the information and all recommendations described in the EIA Report
(Register No.: AEIAR-136/2009), the application documents including all
attachments (Application Nos. AEP-347/2009, VEP-314/2010, FEP-112/2010 and
FEP-139/2012), other relevant documents in the Register; and the information or
mitigation measures described in this Permit, and mitigation measures to be
recommended in submissions that shall be deposited with or approved by the
Director as a result of permit conditions contained in this Permit, and
mitigation measures to be recommended under on going surveillance and
monitoring activities during all stages of the Project. Where recommendations
referred to in the documents of the Register are not expressly referred to in
this Permit, such recommendations are nevertheless to be implemented unless
expressly excluded or impliedly amended in this Permit.
³\¥iÃÒ«ù¦³¤H¡A¶·½T«O¤uµ{¶µ¥Øªº³]p¤Î«Ø³y¡A«ö·Ó¤Uz¸ê®Æ¤Î±¹¬I¿ì²z¡GÀôµû³ø§i(µn°O¥U½s¸¹¡GAEIAR-136/2009)¡B¥Ó½Ð¤å¥ó¥]¬A©Ò¦³ªþ¥ó(¥Ó½Ð®Ñ½s¸¹: AEP-347/2009¡BVEP-314/2010 ¡BFEP-112/2010¤ÎFEP-139/2012) ©Ò»¡©úªº¸ê®Æ¤Î©Ò¦³«Øij¡Fµn°O¥U¤ºªº¨ä¥L¬ÛÃö¤å¥ó¡F¥»³\¥iÃÒ©Ò»¡©úªº¸ê®Æ¤Î½w¸Ñ±¹¬I¡F®Ú¾Ú¥»³\¥iÃÒ¤º¸üªº±ø¥ó¶·¦V¸pªø¦s©ñ©ÎÀò¸pªø§å㪺´£¥æ¤å¥ó©Ò«Øijªº½w¸Ñ±¹¬I¡F¥H¤Î¦b¤uµ{¶µ¥Ø¦U¶¥¬q¶i¦æªº«ùÄòºÊ¹î¤ÎºÊ´ú¤u§@©Ò«Øijªº½w¸Ñ±¹¬I¡Cµn°O¥U¤å¥ó©Òz«Øij¦p¨S¦³¦b¥»³\¥iÃÒ©ú½Tªí¥Ü¡A«h¤´¶·¹ê¬I³o¨Ç«Øij¡A°£«DÀò¥»³\¥iÃÒ©ú½TÁÅ°£©ÎÀq¥Ü×q¡C
1.8
All deposited submissions, as required under this
Permit, shall be rectified and resubmitted in accordance with the comments, if
any, made by the Director within one month of the receipt of the Director¡¦s
comments or otherwise as specified by the Director.
©Ò¦³«ö¥»³\¥iÃÒ³W©w¦s©ñªº¤å¥ó¡A¶·¦b±µÀò¸pªøªº·N¨£ (¦p¦³ªÌ) «á1Ӥ뤺 (°£«D¸pªø¥t¦æ«ü©w)¡A®Ú¾Ú¸pªøªº·N¨£¥[¥H×¥¿¨Ã¦A¦V¸pªø´£¥æ¡C
1.9
All submissions approved by the Director, all
submissions deposited without comments by the Director, or all submissions
rectified in accordance with comments by the Director under this Permit shall
be construed as part of the permit conditions described in Part
C of this Permit. Any variation of the submissions shall be approved by the
Director in writing or as prescribed in the relevant permit conditions. Any
non-compliance with the submissions may constitute a contravention of the Environmental Impact Assessment Ordinance (Cap. 499). All submissions or any variation of the
submissions shall be certified by the Environmental Team (ET) Leader and verified
by the Independent Environmental Checker (IEC) referred
to Conditions 2.1 and 2.2 below, before submitting to the Director under
the Permit.
¸pªø§å㪺©Ò¦³´£¥æ¤å¥ó¡B¸pªø¨S¦³µ¹¤©·N¨£ªº©Ò¦³¦s©ñ¤å¥ó¡B©Î®Ú¾Ú¥»³\¥iÃÒ³W©w¥Ñ¸pªøµ¹¤©·N¨£×¥¿ªº©Ò¦³´£¥æ¤å¥ó¡A§¡¶·¸àÄÀ爲¥»³\¥iÃÒC³¡ »¡©úªº³\¥iÃÒ±ø¥óªº¤@³¡¤À¡C´£¥æ¤å¥ó¦p¦³¥ô¦ó×q¡A§¡¶·Àò¸pªøªº®Ñ±§åã¡A©Î²Å¦X¦³Ãö³\¥iÃÒ±ø¥óq©úªº³W©w¡C¦p¦³¤£²Å¦X´£¥æ¤å¥óªº±¡ªp¡A«h¥i¯à¹H¤ÏÀô¹Ò¼vÅTµû¦ô±ø¨Ò (²Ä499³¹) ªº³W©w¡C©Ò¦³´£¥æ¤å¥ó©Î´£¥æ¤å¥óªº¥ô¦ó×q¥»¡A§¡¶·«ö¤U¤å±ø¥ó²Ä2.1¤Î2.2¶µ©Òz¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AµM«á¤~«ö¥»³\¥iÃÒ³W©w¦V¸pªø´£¥æ¡C
1.10
The Permit Holder shall release all finalized
submissions as required under this Permit, to the public by depositing copies
in the EIAO Register Office, or in any other places, or any internet websites
as specified by the Director, or by any other means as specified by the
Director for public inspection. For this purpose, the Permit Holder shall
provide sufficient copies of the submissions.
³\¥iÃÒ«ù¦³¤H¶·§â©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó©w½Z¤½¶}µ¹¤½衆¤H¤hª¾¹D¡A¤èªk¬O§â¦³Ãö¤å¥ó½Æ¥»¦s©ñ©óÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B¡A©Î¸pªø«ü©wªº¥ô¦ó¨ä¥L¦a¤è¡A©Î¸pªø«ü©wªº¥ô¦ó¤¬Ápºôºô¯¸¡A©Î±Ä¨ú¸pªø«ü©wªº¥ô¦ó¨ä¥L¤èªk¡A¥H¨Ñ¤½衆¬d¾\¡C¦]¦¹¡A³\¥iÃÒ«ù¦³¤H¶·´£¨Ñ¨¬°÷¼Æ¶qªº½Æ¥»¡C
1.11
All submissions to the Director required under this
Permit shall be delivered either in person or by registered mail to the EIAO
Register Office (currently at 27/F, Southorn Centre,
¥»³\¥iÃÒ³W©w¦V¸pªø´£¥æªº©Ò¦³¤å¥ó¡A¶·¿Ë¨°e¥æ©Î¥H±¾¸¹¤è¦¡¶l±H¦ÜÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B (²{§}爲¡G»´äÆW¥J°a¥§¸Ö¹D130¸¹×¹y¤¤¤ß27¼Ó)¡C©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó©w½Zªº¹q¤lª©¥»¡A§¡¶·¥H¶W¤å¥»¼Ð¥Ü»y¨¥ (HTML) (²Ä4.0©Î¸û«áª©¥») ©MÄâ±a«¬¤å¥ó®æ¦¡ (PDF) (²Ä1.3©Î¸û«áª©¥») »s§@¡A°£«D¥tÀò¸pªø¦P·N¡A¨Ã¶·»Pµw½Æ¥»¦P®É´£¥æ¡C
1.12
The Permit Holder shall notify the Director in writing
the commencement date(s) of construction of the Project at least two weeks
prior to the commencement of construction of the Project. The Permit Holder
shall notify the Director in writing immediately if there is any change of the
commencement date(s) of the construction.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A¦Ü¤Ö´£¦2¬P´Á¥H®Ñ±¤è¦¡§â«Ø³y¤uµ{ªº¬I¤u¤é´Á³qª¾¸pªø¡C«Ø³y¬I¤u¤é´Á¦p¦³¥ô¦ó§ó§ï¡A³\¥iÃÒ«ù¦³¤H¥²¶·¥ß§Y¥H®Ñ±¤è¦¡³qª¾¸pªø¡C
1.13
For
the purpose of this Permit, ¡§commencement of construction¡¨ does not include
works related to site clearance and preparation, or other works as agreed by
the Director.
爲°õ¦æ¥»³\¥iÃÒ¡A¡u«Ø³y¤uµ{¶µ¥Øªº®i¶}¡v¤£¥]¬A¦³Ãö¤u¦a²M²z©M¹w³Æªº¤uµ{¡A©Î¸pªø¦P·Nªº¨ä¥L¤uµ{¡C
2.
Submissions or Measures before Commencement of Construction of the
Project
¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¶·´£¥æªº¤å¥ó©Î±Ä¨úªº±¹¬I
Employment of Environmental Monitoring and Audit
(EM&A) Personnel
¸u¥ÎÀô¹ÒºÊ¹î¤Î¼f®Ö¡]ÀôºÊ¡^¤Hû
2.1
An Environmental Team (ET)
shall be established by the Permit Holder no later than one month before the
commencement of construction of the Project. The ET shall not be in any
way an associated body of the Contractor or the Independent Environmental
Checker (IEC) for the Project. The ET shall be headed by an ET Leader. The
ET Leader shall be a person who has at least 7 years of experience in
environmental monitoring and auditing (EM&A) or environmental
management. The ET and the ET Leader shall be responsible for the
implementation of the EM&A programme in accordance with the EM&A
requirements as contained in the EM&A Manual of the Project. The ET
Leader shall keep a contemporaneous log-book of each and every instance or
circumstance or change of circumstances, which may affect the compliance with
the recommendations of the EIA Report (Register No.:
AEIAR-136/2009) and this Permit. The ET Leader shall notify the IEC
within one working day of the occurrence of any such instance or circumstance
or change of circumstances. The ET Leader¡¦s log-book shall be kept readily
available for inspection by all persons assisting in supervision of the
implementation of the recommendations of the EIA Report (Register No.: AEIAR-136/2009) and this Permit or by the Director
or his authorized officers. Failure to maintain records in the log-book,
failure to discharge the duties of the ET Leader as defined in the EM&A
Manual or failure to comply with this Condition would entitle the Director to
require the Permit Holder by notice in writing to replace the ET Leader. Failure
by the Permit Holder to make replacement, or further failure to keep
contemporaneous records in the log-book despite the employment of a new ET Leader may
render the Permit liable to suspension, cancellation or variation.
¦b«Ø³y¤uµ{¶µ¥Øªº®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦1Ӥ릨¥ß¤@ÓÀô¹Ò¤p²Õ¡CÀô¹Ò¤p²Õ¤£±o»P¤uµ{¶µ¥Øªº©Ó¿ì°Ó©Î¿W¥ßÀô¹Ò¬d®Ö¤H¦³¥ô¦óÁpô¡CÀô¹Ò¤p²Õ¶·¥Ñ¤@¦WÀô¹Ò¤p²Õ²Õªø±a»â¡CÀô¹Ò¤p²Õ²Õªø¶·¦bÀô¹ÒºÊ¹î¤Î¼f®Ö (¡uÀôºÊ¡v) ©ÎÀô¹ÒºÞ²z¤è±¦Ü¤Ö¦³7¦~¸gÅç¡CÀô¹Ò¤p²Õ¤ÎÀô¹Ò¤p²Õ²Õªø¶·«ö¤uµ{¶µ¥ØªºÀôºÊ¤â¥U¤º¸üªºÀôºÊ³W©w¡A°õ¦æÀôºÊp¹º¡CÀô¹Ò¤p²Õ²Õªø¶·«O¦s¤@¥»°O¿ý¥U¡A¦P®É°O¸ü¥i¯à·|¼vÅTÀôµû³ø§i (µn°O¥U½s¸¹¡GAEIAR-136/2009) ªº«Øij¤Î¥»³\¥iÃÒªº²Å¦X±¡ªpªº¨C©v¨Æ¥ó¡B¨CºØ±¡ªp©Î¨C¦¸±¡ªpÅܤơCÀô¹Ò¤p²Õ²Õªø¶·¦bµo¥Í¥ô¦óÃþ¦ü¨Æ¥ó¡B ±¡ªp©Î±¡ªpÅܤƫá1Ó¤u§@¤Ñ¤º³qª¾¿W¥ßÀô¹Ò¬d®Ö¤H¡C¦s©ñÀô¹Ò¤p²Õ²Õªøªº°O¿ý¥Uªº¦a¤è¡A¶·¥i¨Ñ¨ó§U·þ¾É°õ¦æÀôµû³ø§i (µn°O¥U½s¸¹¡GAEIAR-136/2009) ªº«Øij¤Î¥»³\¥iÃÒªº©Ò¦³¤H¤h¡B¸pªø©ÎÀò±ÂÅv¤HûÀH®É¬d¾\¡CÀô¹Ò¤p²Õ²Õªø¦p¥¼¯à¦b°O¿ý¥U«O¦s°O¿ý¡B¥¼¯à°õ¦æÀôºÊ¤â¥U©Ò¦C©úªºÀô¹Ò¤p²Õ²ÕªøÀô¾°È©Î¥¼¯à²Å¦X¥»±ø¥óªº³W©w¡A¸pªø¦³Åv¥H®Ñ±n¨D³\¥iÃÒ«ù¦³¤HºM´«Àô¹Ò¤p²Õ²Õªø¡C³\¥iÃÒ«ù¦³¤H¦p¥¼¯à¦w±Æ¤H¿ï´À¸É¡A©Î¦b¸u¥Î·sÀô¹Ò¤p²Õ²Õªø«á¤´¥¼¯à¦b°O¿ý¥U«O¦s¦P´Áªº°O¿ý¡A©Î·|¾ÉP³\¥iÃÒ¾D¼È®É¦Q¾P¡B¨ú®ø©Î§ó§ï¡C
2.2
An IEC
shall be employed by the Permit Holder no later than one month before the
commencement of construction of the Project. The IEC shall not be in any
way an associated body of the Contractor or the ET for the Project. The
IEC shall be a person who has at least 7 years of experience in EM&A or
environmental management. The IEC shall be responsible for duties defined
in the EM&A Manual and shall audit the overall EM&A performance,
including the implementation of all environmental mitigation measures,
submissions required in the EM&A Manual, and any other submissions required
under this Permit. In addition, the IEC shall be responsible for verifying
the environmental acceptability of permanent and temporary works, relevant
design plans and submissions under this Permit. The IEC shall verify the
log-book(s) mentioned in Condition 2.1 of this Permit. The IEC shall
notify the Director by fax, within one working day of receipt of notification
from the ET Leader of each and every change of circumstances or non-compliance
with the recommendations of the EIA Report (Register
No.: AEIAR-136/2009) and this Permit, which might affect the monitoring
or control of adverse environmental impacts from the Project. In case the
IEC fails to so notify the Director of the same, fails to discharge the duties
of the IEC as defined in the EM&A Manual or fails to comply with this
Condition, the Director may require the Permit Holder by notice in writing to
replace the IEC. Failure to replace the IEC as directed or further failure
to so notify the Director despite employment of a new IEC may render the Permit
liable to suspension, cancellation or variation. Notification by the Permit
Holder is the same as notification by the IEC for the purpose of this
Condition.
¦b«Ø³y¤uµ{¶µ¥Øªº®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦1Ó¤ë¸u¥Î¤@¦W¿W¥ßÀô¹Ò¬d®Ö¤H¡C¿W¥ßÀô¹Ò¬d®Ö¤H¤£±o»P¤uµ{¶µ¥Øªº©Ó¿ì°Ó©ÎÀô¹Ò¤p²Õ¦³¥ô¦óÁpô¡C¿W¥ßÀô¹Ò¬d®Ö¤H¶·¦bÀôºÊ©ÎÀô¹ÒºÞ²z¤è±¦Ü¤Ö¦³7¦~¸gÅç¡C¿W¥ßÀô¹Ò¬d®Ö¤H¶·°õ¦æÀôºÊ¤â¥U©Ò¦C©úªºÂ¾°È¡A¥H¤Î¼f®Ö¾ãÅéÀôºÊ¤u§@ªºªí²{¡A¥]¬A¹ê¬I©Ò¦³Àô¹Ò½w¸Ñ±¹¬I¡B´£¥æÀôºÊ¤â¥U³W©wªº¤å¥ó¡A¥H¤Î´£¥æ¥»³\¥iÃÒ©Òn¨Dªº¨ä¥L¤å¥ó¡C¦¹¥~¡A¿W¥ßÀô¹Ò¬d®Ö¤H¶·®Ö¹ê¥Ã¤[¤ÎÁ{®É¤uµ{¦bÀô¹Ò¤Wªº¥i±µ¨üµ{«×¡B¬ÛÃöªº³]p¹Ï«h©M®Ú¾Ú¥»³\¥iÃÒ´£¥æªº¤å¥ó¡A¨Ã¶·®Ö¹ê¥»³\¥iÃÒ±ø¥ó²Ä2.1¶µ©Òzªº°O¿ý¥U¡C¦b¨C¦¸¥X²{¨Æ¬G¡B±¡ªpÅܤƩΤ£²Å¦XÀôµû³ø§i (µn°O¥U½s¸¹¡GAEIAR-136/2009) ¤Î¥»³\¥iÃÒªº±¡ªp¡A¦Ó¥i¯à·|§«Ãª¤uµ{¶µ¥Ø©Ò³y¦¨¤£¨}Àô¹Ò¼vÅTªººÊ¹î©Î±±¨î¤u§@®É¡A¿W¥ßÀô¹Ò¬d®Ö¤H¶·¦b±µÀòÀô¹Ò¤p²Õ²Õªø³qª¾«á1Ó¤u§@¤Ñ¤º¥H¶Ç¯u¤è¦¡³qª¾¸pªø¡C¿W¥ßÀô¹Ò¬d®Ö¤H¦p¥¼¯à³qª¾¸pªø¦³Ãö±¡ªp¡B¥¼¯à°õ¦æÀôºÊ¤â¥U©Ò¦C©úªº¿W¥ßÀô¹Ò¬d®Ö¤H¾°È©Î¥¼¯à²Å¦X¥»±ø¥óªº³W©w¡A¸pªø¥i¥H®Ñ±n¨D³\¥iÃÒ«ù¦³¤HºM´«¿W¥ßÀô¹Ò¬d®Ö¤H¡C¦p¥¼¯à«ö«ü¥ÜºM´«¿W¥ßÀô¹Ò¬d®Ö¤H¡A©Î¦b¸u¥Î·s¿W¥ßÀô¹Ò¬d®Ö¤H«á¤´¥¼¯à³qª¾¸pªø¦³Ãö±¡ªp¡A«h©Î·|¾ÉP³\¥iÃÒ¾D¼È®É¦Q¾P¡B¨ú®ø©Î§ó§ï¡C爲°õ¦æ¥»±ø¥ó¡A³\¥iÃÒ«ù¦³¤Hªº³qª¾µ¥¦P¿W¥ßÀô¹Ò¬d®Ö¤Hªº³qª¾¡C
Management Organization of Main Construction
Companies
¥Dn«Ø³y¤½¥qªººÞ²z¬[ºc
2.3
The
Permit Holder shall, at least two weeks before the commencement of construction
of the Project, inform the Director in writing the management organization of
the main construction companies and/or any form of joint ventures associated
with the construction of the Project. The submitted information shall
include at least an organization chart, names of responsible persons and their
contact details.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A¦Ü¤Ö´£¦2Ó¬P´Á§â¥Dn«Ø³y¤½¥q¤Î / ©Î¥H¥ô¦ó§Î¦¡»P«Ø³y¤uµ{¬ÛÃöªº¦XÀç¥ø·~ªººÞ²z¬[ºc¡A¥H®Ñ±³qª¾¸pªø¡C´£¥æªº¸ê®Æ¶·¦Ü¤Ö¥]¬A¤@¥÷²Õ´¹Ï¡Bt³d¤Hªº©m¦W¤ÎÁpµ¸¸ê®Æ¡C
Submission of Landscape Plan for the Location
shown in Figure 1
´£¥æ¸ü©óªþ¹Ï1¦aÂIªº´ºÆ[¬ü¤Æp¹º
2.4
The Permit Holder shall, at least one month before the commencement of
construction of the location shown in Figure 1, submit four hard copies and one electronic copy
of a landscape plan for the location
shown in Figure 1 (including the tree survey report, the tree preservation proposal, the
tree transplantation proposal and the compensatory planting proposal) to the
Director for approval. The landscape plan shall show the location, size, number
and species of planting, the implementation programme, the maintenance and
management schedules, and drawings in an appropriate scale showing the
landscape and visual mitigation measures of the Project. Before submission to
the Director, the landscape plan shall be certified by the ET Leader and
verified by the IEC as conforming to the information
and recommendations contained in the approved EIA report (Register No. AEIAR-136/2009).
All measures recommended in the approved landscape plan shall be fully and
properly implemented.
¦b¸ü©óªþ¹Ï1¦aÂIªº«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦1Ó¤ë§â¸ü©óªþ¹Ï1¦aÂIªº´ºÆ[¬ü¤Æp¹º¡]¥]¬A¾ð¤ì½Õ¬d³ø§i¡B¾ð¤ì«O¦s«Øij¡B¾ð¤ì²¾´Ó«Øij¡A¥H¤Î¸ÉÀvºØ´Ó«Øij¡^ªº4¥÷µw½Æ¥»¤Î1¥÷¹q¤lª©¥»´£¥æ¸pªø§å®Ö¡C´ºÆ[¬ü¤Æp¹º¶·¥]¬AºØ´Óªº¦aÂI¡B¤j¤p¡B¼Æ¶q¤Î«~ºØ¡B°õ¦æp¹º¡B«O¾i¤ÎºÞ²zµ{§Ç¡A¥H¤Î¦X¾A¤ñ¨Òªº¹Ï«h¡A¥H®i¥Ü¤uµ{¶µ¥Øªº´ºÆ[¤Îµøı¼vÅT½w¸Ñ±¹¬I¡C´ºÆ[¬ü¤Æp¹º¦b´£¥æ¸pªø«e¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú¨ä²Å¦X¸g®ÖãÀôµû³ø§i¡]µn°O¥U½s¸¹¡GAEIAR-136/2009¡^¤º¸üªº¸ê®Æ¤Î«Øij¡C®Ö㪺´ºÆ[³]p¹Ï«Øijªº©Ò¦³±¹¬I¶·¹ý©³¤Î§´µ½°õ¦æ¡C
Submission of Archaeological Field Survey Report for
Red Alignments at Section 3 of Project
´£¥æ¤uµ{¶µ¥Ø²Ä3³¡¤À¬õ¦â©w½uªº¦Ò¥j¹ê¦a½Õ¬d³ø§i
2.5
The Permit
Holder shall, at least one month before the commencement of construction of
Section 3 of the Project, submit four hard copies and one electronic copy of
the archaeological field survey report for the red alignments at
Section 3 of the Project
(including the survey findings and the mitigation measures to protect
archaeological potentials if found before or after the commencement of
construction) to the Director for approval. Before submission to the Director,
the archaeological field survey report shall be certified by the ET Leader and
verified by the IEC as conforming to the information and recommendations
contained in the approved EIA report (Register No. AEIAR-136/2009).
¦b¤uµ{¶µ¥Ø²Ä3³¡¤À«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦1Ó¤ë§â¤uµ{¶µ¥Ø²Ä3³¡¤À¬õ¦â©w½uªº¦Ò¥j¹ê¦a½Õ¬d³ø§i¡]¥]¬A½Õ¬dµ²ªG¡A¥H¤Î¥Î¥H«OÅ@¦b«Ø³y¤uµ{®i¶}«e©Î«áµo²{ªº¦Ò¥j¼çÂ꺽w¸Ñ±¹¬I¡^ªº4¥÷µw½Æ¥»¤Î1¥÷¹q¤lª©¥»´£¥æ¸pªø§å®Ö¡C¦Ò¥j¹ê¦a½Õ¬d³ø§i¦b´£¥æ¸pªø«e¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú¨ä²Å¦X¸g®ÖãÀôµû³ø§i¡]µn°O¥U½s¸¹¡GAEIAR-136/2009¡^¤º¸üªº¸ê®Æ¤Î«Øij¡C
3.
Measures during Construction of the Project
¤uµ{¶µ¥Ø«Ø³y´Á¶¡¶·±Ä¨úªº±¹¬I
3.1
No
water extraction from sensitive water bodies such as rivers, streams, drainage
channels, marshes and ponds shall be allowed for the construction of the
Project.
¤£±o±q±Ó·P¤ôÅé¡A¦pªe¬y¡B·Ë¼î¡B±Æ¤ô´ë¡Bªh¿A¤Î¦À¶í©â¤ô¨Ñ¤uµ{¶µ¥Øªº«Ø³y¨Ï¥Î¡C
3.2
To
protect the species of conservation importance as recommended in the EIA
report, protective fencing for Aquilaria sinensis at Section 3 of the
Project shall be erected.
³\¥iÃÒ«ù¦³¤H¶·«öÀôµû³ø§iªº«Øij¡A¬°¥Íªø¦b¤uµ{¶µ¥Øªº²Ä3³¡¤Àªº¤ú»¾ð½Ý³]¨¾Å@³ò¬]¡A¥H«OÅ@¨ã«O¨|»ùȪº´Óª««~ºØ¡C
4.
Environmental Monitoring and Audit Requirements
Àô¹ÒºÊ¹î¤Î¼f®Ö³W©w
4.1
The
EM&A programme of the Project shall be implemented in accordance with the
procedures and requirements as set out in the EM&A Manual of the approved
EIA Report (Register No. AEIAR-136/2009) of the Project. Any change to the
EM&A requirements or programme shall be justified by the ET Leader and
verified by the IEC as conforming to the requirements set out in the EM&A
Manual and shall seek the prior approval from the Director before
implementation.
¤uµ{¶µ¥ØªºÀôºÊp¹º¶·«ö·Ó¤uµ{¶µ¥Ø®ÖãÀôµû³ø§iªºÀôºÊ¤â¥U¡]µn°O¥U½s¸¹¡GAEIAR-136/2009¡^©Ò¸üµ{§Ç¤Î³W©w°õ¦æ¡CÀôºÊ³W©w©Îp¹º¦p¦³§ó§ï¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø´£¥X¥R¤À²z¥Ñ¡A¨Ã¥Ñ¿W¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú¨ä²Å¦XÀôºÊ¤â¥U©Ò¸ü³W©w¡A¨Ã¶·¨Æ¥ýÀò¸pªø§åã¡AµM«á¤~¥i°õ¦æ¡C
4.2
Samples,
measurements and necessary remedial actions shall be taken in accordance with
the requirements of the EM&A Manual by:
(i)
conducting baseline environmental monitoring;
(ii)
conducting impact monitoring;
(iii)
carrying out remedial actions described in the
Event/Action Plans of the EM&A Manual in accordance with the time frame set
out in the Event/Action Plans, or as agreed by the Director, in case where specified
criteria in the EM&A Manual are exceeded; and
(iv)
logging and keeping records of the details of (i) to
(iii) above for all parameters within 3 working days of the collection of data
or completion of remedial action(s), for the purpose of preparing and submitting
the monthly EM&A Reports and to make available the information for
inspection on site.
¨ú¼Ë¡B´ú¶q¤Î±Ä¨ú¥²nªº¸É±Ï¦æ°Ê®É¡A§¡¶·«ö·ÓÀôºÊ¤â¥Uªº³W©w¶i¦æ¡G
(i)
¶i¦æÀô¹Ò°ò½uºÊ´ú¡F
(ii)
¶i¦æ¼vÅTºÊ´ú¡F
(iii)
¦p¶W¹OÀôºÊ¤â¥U¤º«ü©wªº¼Ð·Ç¡A«h«ö·ÓÀôºÊ¤â¥U¤ºªº¨Æ¥ó/¦æ°Êp¹º©Òq©úªº®É©Î¸pªø©Ò¦P·Nªº®É¡A°õ¦æ¨Æ¥ó/¦æ°Êp¹º©Ò»¡©úªº¸É±Ï¦æ°Ê¡F¥H¤Î
(iv)
¦b¦¬¶°¸ê®Æ©Î§¹¦¨¸É±Ï¦æ°Ê3Ó¤u§@¤Ñ¤º¡A¶·°O¿ý¤Î³Æ¦s¤W¤å(i)¦Ü(iii)¶µ¦U°Ñ¼Æªº¸Ô±¡¡A¥Î§@ÀÀ³Æ¨Ã´£¥æ¨C¤ëÀôºÊ³ø§i¡A¨Ã³Æ§´¦³Ãö¸ê®Æ¥H¨Ñ¦b¤u¦a¬d¾\¡C
4.3
All EM&A results submitted
under this Permit shall be true, valid and correct.
®Ú¾Ú¥»³\¥iÃÒ´£¥æªº©Ò¦³ÀôºÊ¸ê®Æ¡A§¡¶·¦³®Ä¤Î¯u¹êµL»~¡C
4.4
Four
hard copies and one electronic copy of Baseline Monitoring Report shall be
submitted to the Director at least 2 weeks before the commencement of
construction of the Project. The submissions shall be certified by the ET
Leader and verified by the IEC as having complied with the requirements as set
out in the EM&A Manual before submission to the Director. Additional
copies of the Baseline Monitoring Report shall be provided upon request by the
Director.
¦b¤uµ{¶µ¥Ø«Ø³y¤uµ{®i¶}«e¡A¶·¦Ü¤Ö´£¦2Ó¬P´Á¦V¸pªø´£¥æ°ò½uºÊ´ú³ø§iªº4¥÷µw½Æ¥»¤Î1¥÷¹q¤lª©¥»¡C¤å¥ó¦b´£¥æ¸pªø«e¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú²Å¦XÀôºÊ¤â¥U©Ò¸üªº³W©w¡C¦p¸pªøn¨D¡A«h¶·´£¥æ°ò½uºÊ´ú³ø§iªºÃB¥~½Æ¥»¡C
4.5
Four
hard copies and one electronic copy of Monthly EM&A Reports for the
construction stage of the Project shall be submitted to the Director, within 2
weeks after the end of the reporting month. The monthly EM&A Reports
shall include a summary of all non-compliance (exceedances) of the
environmental quality performance limits (Action and Limit Levels). The
submissions shall be certified by the ET Leader and verified by the IEC as
having complied with the requirements as set out in the EM&A Manual before
submission to the Director. Additional copies of the Monthly EM&A Reports
shall be provided upon request by the Director.
¦b³W©w´£¥æ³ø§iªº¤ë¥÷µ²§ô«á2Ó¬P´Á¤º¡A¶·¦V¸pªø´£¥æ¤uµ{¶µ¥Ø«Ø³y¶¥¬qªº¨C¤ëÀôºÊ³ø§iªº4¥÷µw½Æ¥»¤Î1¥÷¹q¤lª©¥»¡C¨C¤ëÀôºÊ³ø§i¶·¥]¬A¦UºØ¤£²Å¦X¡]¶W¥X¡^Àô¹Ò½è¯Àªí²{³W¡]¦æ°Ê¤Î·¥¤ô¥¡^±¡ªpªººKn¡C¤å¥ó¦b´£¥æ¸pªø«e¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú²Å¦XÀôºÊ¤â¥U©Ò¸üªº³W©w¡C¦p¸pªøn¨D¡A«h¶·´£¥æ¨C¤ëÀôºÊ³ø§iªºÃB¥~½Æ¥»¡C
5.
Electronic Reporting of EM&A Information
ÀôºÊ¸ê®Æªº¹q¤l¶×³ø
5.1
To
facilitate public inspection of the Baseline Monitoring Report and Monthly
EM&A Reports via the EIAO Internet Website and at the EIAO Register Office,
electronic copies of these Reports shall be prepared in Hyper Text Markup
Language (HTML) (version 4.0 or later) and in Portable Document Format (PDF
version 1.3 or later), unless otherwise agreed by the Director and shall be
submitted at the same time as the hard copies as described in Conditions 4.4
and 4.5 above of this Permit. For the HTML version, a content page capable
of providing hyperlink to each section and sub-section of these Reports shall
be included in the beginning of the document. Hyperlinks to all figures,
drawings and tables in these Reports shall be provided in the main text from
where the respective references are made. All graphics in these Reports
shall be in interlaced GIF format unless otherwise agreed by the
Director. The content of the electronic copies of these Reports must be
the same as the hard copies.
爲¤è«K¤½衆³z¹LÀôµû±ø¨Ò¤¬Ápºôºô¯¸¤Î¦bÀôµû±ø¨Òµn°O¥U¿ì¨Æ³B¬d¾\°ò½uºÊ´ú³ø§i¤Î¨C¤ëÀôºÊ³ø§i¡A¥H¶W¤å¥»¼Ð¥Ü»y¨¥¡]HTML¡^¡]²Ä4.0©Î¸û«áª©¥»¡^¤ÎÄâ±a«¬¤å¥ó®æ¦¡¡]PDF¡^¡]²Ä1.3©Î¸û«áª©¥»¡^»s§@ªº³ø§iªº¹q¤lª©¥»¡A°£«D¥tÀò¸pªø¦P·N¡A¶·»P¥»³\¥iÃÒ±ø¥ó²Ä4.4¤Î4.5¶µ©Ò»¡©úªºµw½Æ¥»¦P®É´£¥æ¡CÃö©óHTMLªºª©¥»¤è±¡A¥i»P³ø§i¦U¸`¤Î¤p¸`§@¥X¶W¤å¥»³sµ²ªº¥Ø¿ý¶·¦b¤å¥ó¶}ºÝ¥[¤J¡C³ø§i¤º¦UÃþ¹Ïªí¶·¦b¸ü¦³¬ÛÃö¸ê®Æªº¥¿¤å¤º§@¥X¶W¤å¥»³sµ²¡C°£«D¥tÀò¸pªø¦P·N¡A³ø§i¤º©Ò¦³¹Ï§Î§¡¶·¥H¥æ¿ù¦s¨úªºGIF®æ¦¡¨î©w¡C³ø§iªº¹q¤lª©¥»¤º®e¡A¥²¶·»Pµw½Æ¥»ªº¤º®e¤@P¡C
5.2
The
Permit Holder shall, within six weeks after the commencement of construction of
the Project, set up a dedicated Internet web site and notify the Director in
writing the Internet address where the environmental monitoring data and project
information is to be placed. All environmental monitoring data described
in Condition 5.1 above shall be made available to the public via the
abovementioned dedicated Internet web site in the shortest possible time and in
any event no later than 2 weeks after the relevant environmental monitoring
data are collected or become available, unless otherwise agreed with the
Director.
³\¥iÃÒ«ù¦³¤H¶·¦b«Ø³y¤uµ{¶µ¥Øªº®i¶}«á6Ó¬P´Á¤º¡A³]¥ß¯S©wºô¯¸¦s©ñ¤uµ{¶µ¥Ø¸ê®Æ¤Î¤W¤å±ø¥ó²Ä5.1¶µ»¡©úªº©Ò¦³Àô¹ÒºÊ¹î¸ê®Æ©M³ø§i¤Î¥»³\¥iÃÒn¨D´£¥æªº³ø§i¤Îp¹ºªº³Ì²×ª©¥»¡A¨Ã¥H®Ñ±³qª¾¸pªø¤¬Ápºôºô§}©Ò¦b¡C°£«D¥tÀò¸pªø¦P·N¡A¤W¤å±ø¥ó²Ä5.1¶µ»¡©úªº©Ò¦³Àô¹ÒºÊ¹î¸ê®Æ¤Î³ø§i¡A§¡¶·¾¨§Ö³z¹L¥Ñ³\¥iÃÒ«ù¦³¤H³]¥ßªº¯S©wºô¯¸¨Ñ¤½衆¾\Äý¡A¦b¥ô¦ó±¡ªp¤U§¡¤£±o¿ð©ó¦³Ãö¸ê®Æ¦b¦¬¶°©Î¥i¨Ñµo©ñ«áªº2Ó¬P´Á¤º¤W¸ü¦Ü¸Ó¯S©wºô¯¸¡C
5.3
The
Internet web site as described in Condition 5.2 above shall enable
user-friendly public access to the environmental monitoring data and project
information including the Project Profile and this Environmental
Permit. The Internet web site shall have features capable of:
(i)
providing access to all
environmental monitoring data of this Project collected since the commencement
of construction;
(ii) providing access to all finalized submissions as required under this Permit;
(iii) searching by date;
(iv) searching by types of monitoring data; and
(v) hyperlinking to relevant monitoring data after searching;
or otherwise as agreed by the Director.
¤W¤å±ø¥ó²Ä5.2¶µ»¡©úªº¤¬Ápºôºô¯¸¡A¥²¶·¤è«K¥Î¤á¨Ï¥Î¡AÅý¤½衆®e©ö±µ¹FÀô¹ÒºÊ¹î¸ê®Æ¤Î¤uµ{¶µ¥Ø¸ê®Æ¡A·í¤¤¥]¬A¤uµ{¶µ¥Ø²¤¶¤Î¦¹Àô¹Ò³\¥iÃÒ¡C°£«D¥tÀò¸pªø¦P·N¡A¤¬Ápºôºô¯¸¶·¨ã³Æ³¡¥ó¡A´£¨Ñ¤Uz¥\¯à¡G
(i)
±µ¹F¤uµ{®i¶}«á©Ò¦¬¶°ªº¥þ³¡Àô¹ÒºÊ¹î¸ê®Æ¡F
(ii)
±µ¹F©Ò¦³¥»³\¥iÃÒ¤ºn¨D´£¥æªº¤å¥ó¤Îp¹ºªº³Ì²×ª©¥»
(iii)
«ö¤é´Á·j´M¡F
(iv)
«öºÊ¹î¸ê®ÆÃþ§O·j´M¡F¥H¤Î
(v)
¦b·j´M«á»P¬ÛÃöªººÊ¹î¸ê®Æ§@¥X¶W¤å¥»³sµ²¡C
©Î¸pªø¦P·Nªº¨ä¥L¥\¯à¡C
Notes :
ª`
1. This Permit consists of three parts, namely, PART A
(Main Permit), PART B (Description of Designated Project)
and PART C (Permit Conditions). Any person relying on this
Permit should obtain independent legal advice on the legal implications under
the Ordinance, and the following notes are for general information only.
¥»³\¥iÃÒ¦@¦³3³¡¡A§YA³¡(³\¥iÃÒ¥Dn³¡¤À)¡FB³¡(«ü©w¤uµ{¶µ¥Øªº»¡©ú)¤ÎC³¡(³\¥iÃÒ±ø¥ó)¡C¥ô¦ó´©¤Þ¥»³\¥iÃÒªº¤H¤h¶·´NÀôµû±ø¨Òªºªk«ß§t·N¼x¸ß¿W¥ßªk«ß·N¨£¡A¤Uz§åµù¥u¨Ñ¤@¯ë°Ñ¦Ò¥Î¡C
2. If there is a breach of any condition of this Permit, the Director or
his authorized officer may, with the consent of the Secretary for the
Environment, order the cessation of associated work until the remedial action
is taken in respect of the resultant environmental damage, and in that case the
Permit Holder shall not carry out any associated works without the permission
of the Director or his authorized officer.
¦p¹H¤Ï¥»³\¥iÃÒªº¥ô¦ó±ø¥ó¡A¸pªø©ÎÀò±ÂÅv¤Hû¥i¦bÀô¹Ò§½§½ªøªº¦P·N¤U°Ç¥O°±¤î¬ÛÃö¤uµ{¡Aª½¦Ü³\¥iÃÒ«ù¦³¤H爲©Ò³y¦¨ªºÀô¹Ò·l®`±Ä¨ú¸É±Ï¦æ°Ê爲¤î¡C¦b¦¹±¡ªp¤U¡A³\¥iÃÒ«ù¦³¤H¥¼¸g¸pªø©ÎÀò±ÂÅv¤Hû¦P·N¡A¤£±o¶i¦æ¥ô¦ó¬ÛÃö¤uµ{¡C
3. The Permit Holder may apply under Section 13 of the Ordinance to the
Director for a variation of the conditions of this Permit. The Permit Holder
shall replace the original permit displayed on the construction site by the
amended permit.
³\¥iÃÒ«ù¦³¤H¥i®Ú¾ÚÀôµû±ø¨Ò(¸Ó¡u±ø¨Ò¡v)²Ä13±øªº³W©w¦V¸pªø¥Ó½Ð§ó§ï¥»³\¥iÃÒªº±ø¥ó¡C³\¥iÃÒ«ù¦³¤H¶·¥H¸g×qªº³\¥iÃÒ´À´«¦b«Ø³y¤u¦a¤º®i¥Üªºì¦³³\¥iÃÒ¡C
4.
A person who
assumes the responsibility for the whole or a part of the Project may, before
he assumes responsibility of the Project, apply under Section 12 of the
Ordinance to the Director for a further environmental permit.
©Ó¾á¤uµ{¶µ¥Ø¾ã¶µ©Î³¡¤À¤uµ{ªº³d¥ôªº¤H¡A¦b©Ó¾á³d¥ô¤§«e¡A¥i®Ú¾Ú¸Ó±ø¨Ò²Ä12±øªº³W©w¦V¸pªø¥Ó½Ð·sªºÀô¹Ò³\¥iÃÒ¡C
5. Under Section 14 of the Ordinance, the Director may with the consent of
the Secretary for the Environment, suspend, vary or cancel this Permit. The
suspended, varied or cancelled Permit shall be removed from display at the
construction site.
®Ú¾Ú¸Ó±ø¨Ò²Ä14±øªº³W©w¡A¸pªø¥i¦bÀô¹Ò§½§½ªøªº¦P·N¤U¼È®É¦Q¾P¡B§ó§ï©Î¨ú®ø¥»³\¥iÃÒ¡C¾D¼È®É¦Q¾P¡B§ó§ï©Î¨ú®øªºÀô¹Ò³\¥iÃÒ¥²¶·±q¤uµ{¶µ¥Øªº¤u¦a°£¤U¡A¤£¦A®i¥Ü¡C
6.
If this Permit
is cancelled or surrendered during construction of the Project, another
environmental permit must be obtained under the Ordinance before the
construction of the Project could be continued. It is an offence under Section
26(1) of the Ordinance to construct a designated project listed in Part I of
Schedule 2 of the Ordinance without a valid environmental permit.
¦p¥»³\¥iÃÒ¦b¤uµ{¶µ¥Ø«Ø³y´Á¶¡¨ú®ø©Î¥æ¦^¡A«h¦bÄ~Äò¶i¦æ¤uµ{¶µ¥Ø¤§«e¡A¥²¶·¥ý®Ú¾Ú¸Ó±ø¨Ò³W©w¨ú±o¥t¤@¥÷Àô¹Ò³\¥iÃÒ¡C®Ú¾Ú¸Ó±ø¨Ò²Ä26(1)±øªº³W©w¡A¥ô¦ó¤H¦b¨S¦³¦³®ÄÀô¹Ò³\¥iÃÒªº±¡ªp¤U«Ø³y¸Ó±ø¨Òªþªí2©Ò¦C©úªº«ü©w¤uµ{¶µ¥Ø¡A§YÄݹHªk¡C
7. Any person who constructs the Project
contrary to the conditions in the Permit, and is convicted of an offence under
the Ordinance, is liable: -
(i)
on
a first conviction on indictment to a fine of $2 million and to imprisonment
for 6 months;
(ii)
on
a second or subsequent conviction on indictment to a fine of $5 million and to
imprisonment for 2 years;
(iii)
on
a first summary conviction to a fine at level 6 and to imprisonment for 6
months;
(iv)
on
a second or subsequent summary conviction to a fine of $1 million and to
imprisonment for 1 year; and
(v)
in
any case where the offence is of a continuing nature, the court or magistrate
may impose a fine of $10,000 for each day on which he is satisfied the offence
continued.
¦p¥ô¦ó¤H¦b¹H¤Ï¥»³\¥iÃÒªº±ø¥ó¤U«Ø³y¤uµ{¶µ¥Ø¡A®Ú¾Ú¸Ó±ø¨Ò¡A§YÄݹHªk¡G
(i)
¤@¸g´`¤½¶Dµ{¦¡º¦¸©w¸o¡A¥i³B»@´Ú200¸U¤¸¤ÎºÊ¸T6Ó¤ë¡F
(ii)
¤@¸g´`¤½¶Dµ{¦¡²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú500¸U¤¸¤ÎºÊ¸T2¦~¡F
(iii)
¤@¸g´`²©öµ{¦¡º¦¸©w¸o¡A¥i³B²Ä6¯Å»@´Ú¤ÎºÊ¸T6Ó¤ë¡F
(iv)
¤@¸g´`²©öµ{¦¡²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú100¸U¤¸¤ÎºÊ¸T1¦~¡F¥H¤Î
(v)
¦b¥ô¦ó±¡ªp¤U¦p¸Ó¸o¦æÄݳsÄò©Ê½è¡Aªk°|©Îµô§P©x¥i´N¨ä«H¯Ç¸Ó¸o¦æ³sÄòªº¨C¤@¤Ñ¥t³B»@´Ú10,000¤¸¡C
8. The Permit Holder may appeal against any condition of this Permit under
Section 17 of the Ordinance within 30 days of receipt of this Permit.
³\¥iÃÒ«ù¦³¤H¥i¦b±µÀò¥»³\¥iÃÒ«á30¤Ñ¤º¡A®Ú¾Ú¸Ó±ø¨Ò²Ä17±ø´N¥»³\¥iÃÒªº¥ô¦ó±ø¥ó´£¥X¤W¶D¡C
9. The Notes are for general reference only and that the Permit Holder
should refer to the EIA Ordinance for details and seek independent legal
advice.
¤Wz§åµù¥u¨Ñ¤@¯ë°Ñ¦Ò¥Î¡A±ýª¾¦³Ãö¸Ô±¡¡A³\¥iÃÒ«ù¦³¤H¶·°Ñ¾\Àôµû±ø¨Ò¤Î¼x¸ß¿W¥ßªk«ß·N¨£¡C
Environmental Permit No. FEP-05/347/2009/A
Àô¹Ò³\¥iÃÒ½s¸¹ FEP-05/347/2009/A