3.1
Noise monitoring was conducted
in accordance with the Updated EM&A Manuals. Appendix A shows the
established Action and Limit Levels for the environmental monitoring works.
3.2
Noise monitoring was conducted
at three designated monitoring stations, namely N1, N2 and N3, as summarized in
Table 3.1. Figure
3.1 shows the locations of these stations.
Table
3.1 Noise
Monitoring Stations
Monitoring
Stations |
Description |
N1 |
At ground
level of Village house at No.49-50, Shung Ching San Tsuen |
N2 |
At ground
level of Village house at No.17 Chuk San Tsuen |
N3 |
On roof
of Small Traders New Village Public School besides the Pok Oi Hospital |
3.3
Integrating Sound Level Meters
were used for noise monitoring.
They were Type 1 sound level meters capable of giving a continuous
readout of the noise level readings including equivalent continuous sound
pressure level (Leq) and percentile sound pressure level (Lx). They comply with International
Electrotechnical Commission Publications 651:1979 (Type 1) and 804:1985 (Type
1).
3.4
Table 3.2 summarizes the noise
monitoring equipment model being used. Calibrations of equipments are conducted
annually. Copies of renewed calibration certificates for the reporting month are
attached in Appendix B.
Table
3.2 Noise
Monitoring Equipment
Equipment |
Model and Make |
Qty. |
Integrating
Sound Level Meter |
B&K Model
2238 |
4 |
Rion NL14 |
1 |
|
Calibrator |
B&K 4231 |
2 |
Wind Speed
Anemometer |
Vane Anemometer, Model 451104 |
1 |
Monitoring Parameters, Frequency and Duration
3.5
Table 3.3 summarizes the
monitoring parameters, frequency and total duration of monitoring. The noise
monitoring schedule is shown in Appendix C.
Table
3.3 Noise
Monitoring Parameters, Frequency and Duration
Monitoring
Stations |
Parameter |
Period |
Frequency |
Measurement |
N1 |
L10(30 min.)dB(A) L90(30 min.)dB(A) Leq(30 min.)dB(A) |
0700-1900
on normal weekdays |
Once
per week |
Free
field + 3dB correction |
N2 |
Free
field + 3dB correction |
|||
N3 |
Facade |
Monitoring Methodology and QA/QC
Procedures
3.6
The details of
operating/analytical procedures for noise monitoring are described in the
previous EM&A Monthly reports.
3.7
The details of requirements of
maintenance/calibration are described in the previous EM&A Monthly reports.
3.8
Noise monitoring was performed
at the designated locations during the daytime period (0700 to 1900) as
scheduled in the reporting month. Results and graphical presentations are shown
in Appendix
F.
3.9
The weather during the
monitoring sessions was mainly sunny. Weather conditions are provided in Appendix
F.
3.10
Construction noise monitoring
was conducted as scheduled
except the monitoring at all Stations on 3 August 06 due to hosting of Typhoon
Signal No. 3 as well as at Station B on 9 and 17 August 06 when the school was
closed for summer holiday. No Action/Limit Level exceedance was recorded in the
reporting month.