Appendix H              Summary of Weekly Environmental Site Inspection Observations in August 2006

 

Inspection date

Observation

Contractor’s Follow-up Action

3

8

17

24

31

Ö

 

 

 

 

Blockage of catchpits were found at TTA3, C66 (outfall BB and EE) and C6.

Clear the blockage and desilt regularly.

Ö

 

 

 

 

Accumulated construction waste was found at Area B and broken tree branches and leaves were found at gully of C66 and on carriageway at TTA32.

Improve housekeeping in the site.

Ö

 

 

 

 

Stagnant water was found at Grid 9 site entrance.

Remove the water or level the area.

 

Ö

 

 

 

Oil spillage was observed from a generator and a few oil drums.

Remove the oil stain.

 

Ö

Ö

 

 

Water was observed accumulated in drip trays with generator and oil drums.

Remove the oily water and dispose of as chemical waste.

 

 

Ö

 

 

Stagnant water was found in the refuse collection bin at Grid 6, inside catchpit at FR16 and in the excavated trench at TTA58-S2.

Remove the stagnant water to prevent mosquito breeding.

 

 

Ö

 

 

Untidy condition at Grid 8 and sand deposited at site office area.

Improve housekeeping on site.

 

 

Ö

 

 

Deadleaves were found inside u-channel at TTA58-S2.

Properly maintain the drainage.

 

 

 

Ö

 

Stagnant water was found inside chamber of Grid 8, excavated trench at TTA58-S2, inside u-channel at FR17 and inside catchpit at F16.

Clear the stagnant water regularly.

 

 

 

Ö

 

Broken concrete and leaves were found inside u-channel at TTA3 and C6/C66 and gullies at F16 were found blocked.

Properly maintain the drainage system.

 

 

 

Ö

 

Sand was found on carriageway at TTA12. General refuse was found at F17 and untidy condition was found at C143.

Improve housekeeping.

 

 

 

 

Ö

Deadleaves were found inside u-channel at TTA3.

Properly maintain the drainage system.

 

 

 

 

Ö

Sand was found on carriageway at TTA3 and deadleaves were found at C545 behind the temple.

Remove sand patches and leaves as soon as possible.

 

 

 

 

Ö

Mud trail was found at the site entrance at F17.

Provide wheel-wash at site exits.