Environmental Permit No. EP-349/2009/L
Àô¹Ò³\¥iÃÒ½s¸¹ EP-349/2009/L
ENVIRONMENTAL IMPACT ASSESSMENT ORDINANCE
(CHAPTER 499)
Àô¹Ò¼vÅTµû¦ô±ø¨Ò
(²Ä499³¹)
²Ä 10¤Î13±ø
ENVIRONMENTAL
PERMIT TO CONSTRUCT AND OPERATE
A DESIGNATED
PROJECT
«Ø³y¤ÎÀç¿ì«ü©w¤uµ{¶µ¥ØªºÀô¹Ò³\¥iÃÒ
A³¡ (³\¥iÃÒ¥Dn³¡¤À)
Pursuant to Section 10 of the Environmental Impact Assessment Ordinance
(the Ordinance), the Director of Environmental Protection (the Director)
granted the Environmental
Permit No. EP-349/2009 to MTR Corporation Limited (hereinafter
referred to as the ¡§Permit Holder¡¨) on
®Ú¾Ú¡mÀô¹Ò¼vÅTµû¦ô±ø¨Ò¡n¡]±ø¨Ò¡^²Ä10±øªº³W©w¡AÀô¹Ò«OÅ@¸p¸pªø¡]¸pªø¡^©ó
The issue of this environmental permit is based on
the documents, approvals or permissions described below:
¥»Àô¹Ò³\¥iÃÒªºµo¥X¡A¤D¥H¤Uªí©Ò¦Cªº¤å¥ó¡B§åã©Î³\¥i§@¬°®Ú¾Ú¡R-
Application No. ¥Ó½Ð®Ñ½s¸¹¡G |
VEP-439/2014 |
Document in the
Register: µn°O¥U¤Wªº¤å¥ó¡G |
(1)
Hong Kong Section of Guangzhou - Shenzhen - Hong Kong Express Rail Link Environmental
Impact Assessment (EIA) Report, Environmental Monitoring and Audit (EM&A)
Manual and Executive Summary (Register No.: AEIAR-143/2009) [Hereinafter referred to as
the ¡§EIA Report¡¨] (1) ¼s²`´ä°ª³tÅK¸ô»´ä¬qÀô¹Ò¼vÅTµû¦ô³ø§i¡AÀô¹ÒºÊ´ú¤Î¼f®Ö¤â¥U¤Î¦æ¬FºKn (µn°O¥UÀɸ¹: AEIAR-143/2009) [¤UºÙ ¡§Àôµû³ø§i¡¨] (2) The Director¡¦s
letter of approval of the EIA report dated (2) ¸pªø©ó (3) The amended pages 5-12, 5-35, 1st
and 3rd pages of Appendix 5.6 of Chapter 5 of the EIA Report
submitted in accordance with the Approval Condition (8) (3) ®Ú¾Ú§åã±ø¥ó(8)¡AÀôµû³ø§i²Ä¤³¹²Ä5-12¡B5-35¶¤Îªþ¿ý5.6¤¤ªº²Ä1¤Î²Ä3¶ªº¸g×qªº¤À¶
(4) Application
for an Environmental Permit No. AEP-349/2009 [Hereafter
referred to as ¡§the Application No. AEP-349/2009¡¨] (4) ¥Ó½ÐÀô¹Ò³\¥iÃÒ½s¸¹ AEP-349/2009[¤UºÙ ¡§¥Ó½Ð®Ñ½s¸¹ AEP-349/ (5)
Environmental Permit (No. EP-349/2009) issued on (5) ©ó (6) Application
for Variation of an Environmental Permit No. VEP-323/2010 and attached
documents submitted by the Permit Holder on (6) ³\¥iÃÒ«ù¦³¤H©ó (7)
Environmental Permit (No. EP-349/2009/A) issued on (7) ©ó2010¦~9¤ë27¤éñµoªºÀô¹Ò³\¥iÃÒ (½s¸¹EP-349/2009/A) (8) Application
for Variation of an Environmental Permit No. VEP-334/2010 and attached
documents submitted by the Permit Holder on (8) ³\¥iÃÒ«ù¦³¤H©ó2010¦~12¤ë29¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-334/2010©Mªþ¥ó (9) Application
for Variation of an Environmental Permit No. VEP-336/2011 submitted by the
Permit Holder on (9) ³\¥iÃÒ«ù¦³¤H©ó2011¦~10¤ë17¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-336/2011©Mªþ¥ó (10)
Application for Variation of an Environmental Permit No. VEP-346/2011
submitted by the Permit Holder on (10) ³\¥iÃÒ«ù¦³¤H©ó2011¦~12¤ë6¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-346/2011©Mªþ¥ó (11)
Application for Variation of an Environmental Permit No. VEP-352/2012
submitted by the Permit Holder on (11) ³\¥iÃÒ«ù¦³¤H©ó2012¦~1¤ë6¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-352/2012©Mªþ¥ó (12)
Application for Variation of an Environmental Permit No. VEP-358/2012
submitted by the Permit Holder on (12) ³\¥iÃÒ«ù¦³¤H©ó2012¦~4¤ë5¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-358/2012©Mªþ¥ó (13)
Application for Variation of an Environmental Permit No. VEP-360/2012
submitted by the Permit Holder on (13) ³\¥iÃÒ«ù¦³¤H©ó2012¦~5¤ë9¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-360/2012©Mªþ¥ó (14)
Application for Variation of an Environmental Permit No. VEP-373/2012
submitted by the Permit Holder on (14) ³\¥iÃÒ«ù¦³¤H©ó2012¦~8¤ë6¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-373/2012©Mªþ¥ó (15)
Application for Variation of an Environmental Permit No. VEP-377/2012
submitted by the Permit Holder on (15) ³\¥iÃÒ«ù¦³¤H©ó2012¦~9¤ë28¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-377/2012©Mªþ¥ó (16)
Application for Variation of an Environmental Permit No. VEP-407/2013
submitted by the Permit Holder on (16) ³\¥iÃÒ«ù¦³¤H©ó2013¦~6¤ë14¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-407/2013©Mªþ¥ó (17)
Application for Variation of an Environmental Permit No. VEP-420/2013
submitted by the Permit Holder on (17) ³\¥iÃÒ«ù¦³¤H©ó2013¦~11¤ë1¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-420/2013©Mªþ¥ó (18)
Application for Variation of an Environmental Permit No. VEP-439/2014
submitted by the Permit Holder on 5 June 2014 and attached documents (18) ³\¥iÃÒ«ù¦³¤H©ó2014¦~6¤ë5¤é´£¥æ§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-439/2014©Mªþ¥ó |
Application No. ¥Ó½Ð®Ñ½s¸¹ |
Date of Application ¥Ó½Ð¤é´Á |
List of Amendments Incorporated into this Environmental Permit ¤w¥]§t¦b¥»Àô¹Ò³\¥iÃÒ¤ºªº×q¶µ¥Ø |
Date of Amendment ×q¤é´Á |
VEP-323/2010 |
|
Rename ¡§emergency
rescue station¡¨ to ¡§emergency rescue sidings¡¨ in Scale and Scope of
Designated Project(s) of Part B, Conditions 2.12(i),
2.31 and ©óB³¡«ü©w¤uµ{¶µ¥Øªº³W¼Ò©M½d³ò¡AC³¡±ø¥ó²Ä2.12(i)¶µ¡B²Ä2.31¶µ¤Î²Ä2.34¶µ¡A§ó§ï¡§ºò«æ±Ï´©¤J¤f¡¨ªº¦WºÙ¬°¡§ºò«æ±Ï´©³B¡¨¡C Vary Condition §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C |
|
VEP-334/2010 |
2010¦~12¤ë29¤é |
Vary Figure
3. §ó§ï¹Ï3¡C Vary Condition 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C Add Conditions 2.40 to 2.42 and renumber the conditions thereafter in Part C. ©óC³¡¥[¤J²Ä2.40¦Ü2.42¶µ±ø¥ó¤Î±N¨ä«áªº±ø¥ó«·s½s¸¹¡C |
2011¦~1¤ë24¤é |
VEP-336/2011 |
2011¦~10¤ë17¤é |
Vary Figure
1. §ó§ï¹Ï1¡C Vary Condition 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C |
2011¦~11¤ë11¤é |
VEP-346/2011 |
2011¦~12¤ë6¤é |
Vary Figure
2 to include
the extension of works boundary for Mong Kok West Ventilation Building Works
Area. §ó§ï¹Ï2¥H¥]¬A©ô¨¤¦è³q·¼ÓªºÂX®i¬I¤u¬É½u¡C Vary Condition 1.7 in Part C to include change of explosive delivery
route for Kwai Chung and the
extension of works boundary for Mong Kok West Ventilation Building Works Area. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¥H¥]¬A¸ª¯Fªº¹B°eÃz¬µ«~¸ô½uªº§ó§ï¤Î©ô¨¤¦è³q·¼ÓªºÂX®i¬I¤u¬É½u¡C |
2011¦~12¤ë30¤é |
VEP-352/2012 |
2012¦~1¤ë6¤é |
Vary Condition 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C Add Conditions 2.43 to 2.44 and renumber the conditions thereafter in Part C. ©óC³¡¥[¤J²Ä2.43¦Ü2.44¶µ±ø¥ó¤Î±N¨ä«áªº±ø¥ó«·s½s¸¹¡C |
2012¦~2¤ë3¤é |
VEP-358/2012 |
2012¦~4¤ë5¤é |
Vary Figure
2. §ó§ï¹Ï2¡C Vary Conditions 1.7
and 2.43 in Part C. §ó§ïC³¡²Ä1.7¤Î2.43¶µ±ø¥ó¡C |
3 May 2012 2012¦~5¤ë3¤é |
VEP-360/2012 |
9 May 2012 2012¦~5¤ë9¤é |
Vary Figure
2. §ó§ï¹Ï2¡C Vary Conditions 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C |
2012¦~6¤ë5¤é |
VEP-373/2012 |
2012¦~8¤ë6¤é |
Vary Conditions 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C |
2012¦~9¤ë3¤é |
VEP-377/2012 |
2012¦~9¤ë28¤é |
Vary Conditions 1.7,
2.26, 2.32, 2.35, 2.36 and delete Condition 2.33 in Part C. §ó§ïC³¡²Ä1.7¡B2.26¡B2.32¡B2.35¡B2.36¤Î删°£2.33¶µ±ø¥ó¡C Add Condition 2.22 and renumber the conditions thereafter in Part C. ©óC³¡¥[¤J²Ä2.22¶µ±ø¥ó¤Î±N¨ä«áªº±ø¥ó«·s½s¸¹¡C |
2012¦~10¤ë26¤é |
VEP-407/2013 |
2013¦~6¤ë14¤é |
Vary Conditions 1.7
and 2.35 in Part C. §ó§ïC³¡²Ä1.7¤Î2.35¶µ±ø¥ó¡C |
2013¦~7¤ë11¤é |
VEP-420/2013 |
2013¦~11¤ë1¤é |
Vary Figure
1. §ó§ï¹Ï1¡C Vary Conditions 1.7
in Part C. §ó§ïC³¡²Ä1.7¶µ±ø¥ó¡C |
2013¦~11¤ë28¤é |
VEP-439/2014 |
5 June 2014 2014¦~6¤ë5¤é |
Vary Figure
2. §ó§ï¹Ï2¡C Vary Conditions 1.7
and 2.35 in Part C. §ó§ïC³¡²Ä1.7¤Î2.35¶µ±ø¥ó¡C |
2 July 2014 2014¦~7¤ë2¤é |
2 July 2014 2014 ¦~7 ¤ë 2 ¤é Date ¤é´Á |
|
(Victor
W.T. YEUNG) Atg.
Principal Environmental Protection Officer (Strategic Assessment) for
Director of Environmental Protection Àô¹Ò«OÅ@¸p¸pªø (¸p²zº®uÀô¹Ò«OÅ@¥D¥ô(µ¦²¤µû¦ô) ·¨ºû¼w¥N ¦æ) |
PART B (DESCRIPTIONS OF
DESIGNATED PROJECT)
B³¡ («ü©w¤uµ{¶µ¥Øªº»¡©ú)
Hereunder is the description of the
designated project mentioned in Part
A of this environmental permit (hereinafter referred to as the
¡§Permit¡¨):
¤U¦C¬°¥»Àô¹Ò³\¥iÃÒ(¤UºÙ¡§³\¥iÃÒ¡¨)A³¡©Ò´£zªº«ü©w¤uµ{¶µ¥Øªº»¡©ú:
Title of
Designated Project «ü©w¤uµ{¶µ¥Øªº¦WºÙ |
Hong Kong Section of ¼s²`´ä°ª³tÅK¸ô»´ä¬q[³o«ü©w¤uµ{¶µ¥Ø¤UºÙ¡§¤uµ{¶µ¥Ø¡¨] |
Nature of
Designated Project |
The
Project is a designated project (DP) under the Ordinance with the following
DP elements: ®Ú¾Ú±ø¨Ò¡A¥»¤uµ{¶µ¥Ø¥]§t¤F¤U¦CÄÝ©ó«ü©w¤uµ{¶µ¥Øªº¤¸¯À¡G -
A
railway and its associated stations (Item A.2 of Part I of Schedule 2 of the
Ordinance); -
ÅK¸ô¤Î¨ä¬ÛÁp¨®¯¸(±ø¨Òªþªí2²ÄI³¡A.2¶µ)¡F -
A
railway siding and maintenance workshop (Item A.4 of Part I of Schedule 2 of
the Ordinance); -
ÅK¸ô°¼½u¤Îºûפu³õ(±ø¨Òªþªí2²ÄI³¡A.4¶µ)¡F -
A
railway tunnel more than 800m in length between portals (Item A.7 of Part I
of Schedule 2 of the Ordinance); and -
¤J¤f¤§¶¡ªºªø«×¶W¹L800¦ÌªºÅK¸ôÀG¹D¡]±ø¨Òªþªí2²ÄI³¡A.7¶µ¡^¡F¤Î -
Project
includes works partly or wholly in a country park or special area, a
conservation area, and a site of special scientific interest (Item Q.1 of
Part I of Schedule 2 of the Ordinance). -
¶µ¥Ø³¡¤À©Î¥þ³¡¦ì©ó²{¦³ªº¥³¥¤½¶é©Î¯S§O¦a°Ï¡B¦ÛµM«O¨|°Ï©M¨ã¦³¯S§O¬ì¾Ç»ùȪº¦aÂI¡]±ø¨Òªþªí2²ÄI³¡Q.1¶µ¡^¡C |
Location of
Designated Project «ü©w¤uµ{¶µ¥Øªº¦aÂI |
The overall view of
alignment and works sites of the Project are shown in Figures 1, 2 and 3 attached to this Permit. |
Scale and Scope of Designated Project(s) «ü©w¤uµ{¶µ¥Øªº³W¼Ò©M½d³ò |
Construction
and operation of the following key elements: «Ø³y©MÀç¿ì¥H¤Uªº¥Dn³¡¥÷¡G -
Approximately
26km of underground railway running from the terminus in -
ªø¬ù26¤½¨½ªº¦a¤UÅK¸ô¡A±q¦è¤EÀsªºÁ`¯¸¦ù©µ¦Ü¬Ó±^Ãä¬É¡F -
A
terminus in -
¦ì©ó¦è¤EÀsªºÁ`¯¸¤Î¨äªþÄÝ«Ø¿vª«¡A¨Ò¦p³q·³]¬I¡B¤½¦@¥æ³q¥æ¶×³B¡BÅܹq¯¸©M®ü¤ô§N«o³]¬I¡F -
Seven
tunnel ventilation buildings at Mai Po, Ngau Tam Mei, Pat Heung, Shing Mun, -
¤C®yÀG¹D³q·¼Ó¡A¤À§O³]©ó¦Ì®H¡B¤û¼æ§À¡B¤K¶m¡B«°ªù¡B¸ª¯F¡B«n©÷©M©ô¨¤¦è¡A¥H¤Î³]©ó¤j¦¿®Hªººò«æ±Ï´©¤J¤f¡F -
Stabling
sidings and maintenance facilities located at Shek Kong (Shek Kong Stabling
Sidings (SSS)) to provide for train stabling, minor maintenance and cleaning; -
¦ì©ó¥Û±^ªº¦C¨®°±©ñ³B¤Îºû׳]¬I(¥Û±^¦C¨®°±©ñ³B)¡A¬°ÅK¸ô´£¨ÑÁ{®É°±ªy¡B¤p«¬ºûשM²M¼äªA°È¡F -
An
emergency rescue sidings (ERS) located next to the SSS; and -
¦ì©ó¥Û±^¦C¨®°±©ñ³B®Çªººò«æ±Ï´©³B(¥Û±^ºò«æ±Ï´©³B)¡F¤Î -
Supporting
works areas, access roads, barging facilities, site explosive magazine and
nursery sites during the construction of the Project. -
©ó¬I¤u´Á¶¡ªº«á¶Ô¬I¤u°Ï¡B·F¹D¤ä¸ô¡BÄ»²îÂà¹B³]¬I¡BÁ{®ÉÃz¬µ«~Ü®w©M´Óª«Å@²z°Ï¡C |
PART C (PERMIT CONDITIONS)
C³¡¡]³\¥iÃÒ±ø¥ó¡^
1. General
Conditions
¤@¯ë±ø¥ó
1.1 The
Permit Holder and any person working on the Project shall comply with all conditions
set out in this Permit. Any non-compliance by any person may constitute a
contravention of the Environmental Impact Assessment Ordinance (Cap. 499) and
may become the subject of appropriate action under the Ordinance.
³\¥iÃÒ«ù¦³¤H¤Î¥ô¦ó±q¨Æ¤uµ{¶µ¥Øªº¤H¤h¥²¶·§¹¥þ²Å¦X¥»³\¥iÃÒ¸ü¦Cªº¥þ³¡±ø¥ó¡C¥ô¦ó¤H¤h¦p¦³¤£²Å¦X¥»³\¥iÃÒªº±¡ªp¡A¥i¯à¹H¤ÏÀô¹Ò¼vÅTµû¦ô±ø¨Ò (²Ä499³¹) ªº³W©w¡A¦Ó·í§½¥i®Ú¾Ú±ø¨Ò±Ä¨ú¾A·í¦æ°Ê¡C
1.2
The Permit Holder shall ensure full compliance with all
legislation from time to time in force including but without limitation to the
Noise Control Ordinance (Cap. 400), Air Pollution Control Ordinance (Cap. 311),
Water Pollution Control Ordinance (Cap. 358), Waste Disposal Ordinance (Cap.
354), Occupational
Safety and Health Ordinance (Cap. 509), Factories and Industrial Undertakings
Ordinance (Cap. 59) and Dangerous Goods Ordinance (Cap.295). This Permit
does not of itself constitute any ground of defence against any proceedings
instituted under any legislation.
³\¥iÃÒ«ù¦³¤H¶·¸g±`½T«O§¹¥þ²Å¦X²{¦æªk¨Òªº³W©w¡A¥]¬A¦ý¤£©ó¾¸µºÞ¨î±ø¨Ò (²Ä400³¹)¡FªÅ®ð¦Ã¬VºÞ¨î±ø¨Ò
(²Ä311³¹)¡F¤ô¦Ã¬VºÞ¨î±ø¨Ò (²Ä358³¹)¡F¼oª«³B¸m±ø¨Ò (²Ä354³¹) ¡F¾·~¦w¥þ¤Î°·±d±ø¨Ò (²Ä509³¹)¡F¤u¼t¤Î¤u·~¸gÀç±ø¨Ò (²Ä59³¹)¤Î¦MÀI«~±ø¨Ò
(²Ä295³¹)¡C®Ú¾Ú¥ô¦óªk¨Ò´£¥Xªºªk«ßµ{§Ç¡A¥»³\¥iÃÒ¥»¨¤£¯à§@¬°¥ô¦ó§ÜÅG²z¾Ú©Îµø¬°¨äªk¨Ò©ÒÀq³\¡C
1.3 The Permit Holder shall
give a copy of this Permit to the person(s) in charge of the Project site(s)
and ensure that such person(s) fully understands all conditions and all
requirements incorporated by the Permit. The Project site(s) refers to site(s)
of construction and operation of the Project and shall mean the same hereafter.
³\¥iÃÒ«ù¦³¤H¶·§â¥»³\¥iÃÒªº¤@¥÷½Æ¥»¥æ¤©¦³Ãö¤u¦aªºt³d¤H¡A¨Ã½T«O³o¨Ç¤H¤h§¹¥þ©ú¥Õ¥»³\¥iÃÒªº©Ò¦³±ø¥ó»P³W©w¡C¤u¦a¬O«ü«Ø³y¤ÎÀç¿ì¤uµ{¶µ¥Øªº¤u¦a¡A¤U¤å©Ò´£¤Îªº¤u¦a¥çÄݦP¤@·N«ä¡C
1.4 The Permit Holder shall
make copies of this Permit together with all documents referred to in this
Permit or the documents referred to in Part A of the Permit readily available at all times for
inspection by the Director or his authorised officers at all Project site(s)
covered by this Permit. Any
reference to the Permit shall include all documents referred to in the Permit
and also the relevant documents in the Register.
³\¥iÃÒ«ù¦³¤H¶·¦L»s¥»³\¥iÃÒªº½Æ¥»¡A³s¦P¥»³\¥iÃÒ©Òzªº©Ò¦³¤å¥ó©Î¥»³\¥iÃÒA³¡©Òz¤å¥ó¡A¥H¨Ñ¸pªø©ÎÀò±ÂÅv¤Hû¦b¥ô¦ó®É¶¡¤º¦b¥»³\¥iÃÒ©Ò²[»\ªº©Ò¦³¤u¦a¬d¾\¡C¤Z´£z¥»³\¥iÃÒ¡A¶·¥]¬A¥»³\¥iÃÒ©Òzªº©Ò¦³¤å¥ó¤Îµn°O¥U¤ºªº¬ÛÃö¤å¥ó¡C
1.5
The Permit Holder shall display conspicuously a copy of this
Permit on the Project site(s) at all vehicular site entrances or at a
convenient location for public¡¦s information at all times. The Permit Holder shall ensure that the
most updated information about the Permit, including any amended permit, is
displayed at such locations. If the Permit Holder surrenders a part or the
whole of the Permit, the notice he sends to the Director shall also be
displayed at the same locations as the original Permit. The suspended, varied
or cancelled Permit shall be removed from display at the Project site(s).
³\¥iÃÒ«ù¦³¤H¶·¦b¤u¦aªº©Ò¦³¨®½ø¤J¤f©Î¤@³B¤è«K¦aÂI¡AÅã²´¦a®i¥Ü¥»³\¥iÃÒªº½Æ¥»¡A¥H¨Ñ¤½²³¦b¥ô¦ó®É¶¡¤º¾\Äý¡C³\¥iÃÒ«ù¦³¤H¶·½T«O¦b³o¨Ç¦aÂI®i¥ÜÃö©ó¥»³\¥iÃÒ (¥]¬A¥ô¦ó¸g×qªº³\¥iÃÒ)
ªº³Ì·s¸ê®Æ¡C³\¥iÃÒ«ù¦³¤H¦p¥æ¦^³\¥iÃÒªº³¡¤À©Î¥þ³¡¡A¥²¶·§â¨ä°e¥æ¸pªøªº³qª¾®Ñ¡A¦b³Æ¦³ì¦³³\¥iÃÒªº¦U³B¬Û¦P¦aÂI®i¥Ü¡C¾D¼È®É¦Q¾P¡B§ó§ï©Î¨ú®øªº³\¥iÃÒ¥²¶·±q¤u¦aªº®i¥Ü¦aÂI°£¤U¡A¤£¦A®i¥Ü¡C
1.6
The Permit Holder shall construct
and operate the Project in accordance with the project descriptions in Part B of this Permit.
³\¥iÃÒ«ù¦³¤H¶·¨Ì¾Ú¥»³\¥iÃÒB³¡ªº»¡©ú¡A«Ø³y¤ÎÀç¿ì¤uµ{¶µ¥Ø¡C
1.7
The Permit Holder shall ensure that
the Project is designed, constructed and operated in accordance with the
information and all recommendations described in the EIA Report (Register No.:
AEIAR- 143/2009), the application documents for an environmental
permit including all attached documents (Application No. AEP-349/2009), the applications for variation of an environmental permit including
all attached documents (Application Nos. VEP-323/2010, VEP-334/2010, VEP-336/2011,
VEP-346/2011, VEP-352/2012, VEP-358/2012, VEP-360/2012, VEP-373/2012,
VEP-377/2012, VEP407/2013, VEP-420/2013 and VEP-439/2014), other relevant documents in the
Register, the information or mitigation measures described in this Permit,
mitigation measures to be recommended in submissions that shall be deposited
with or approved by the Director as a result of permit conditions contained in
this Permit, and mitigation measures to be recommended under on going
surveillance and monitoring activities during all stages of the Project. Where
recommendations referred to in the documents of the Register are not expressly
referred to in this Permit, such recommendations are nevertheless to be
implemented unless expressly excluded or impliedly amended in this Permit.
³\¥iÃÒ«ù¦³¤H¶·½T«O¤uµ{¶µ¥Øªº³]p¡B«Ø³y¤ÎÀç¿ì¡A«ö·Ó¤Uz¸ê®Æ¤Î±¹¬I¿ì²z¡GÀôµû³ø§i(µn°O¥U½s¸¹¡GAEIAR-143/2009)©Ò»¡©úªº¸ê®Æ¤Î«Øij¡F¥Ó½ÐÀô¹Ò³\¥iÃÒ¤å¥ó¥]¬A¥þ³¡ªþ¥ó(¥Ó½Ð®Ñ½s¸¹¡GAEP-349/2009)¡F©Ò¦³§ó§ïÀô¹Ò³\¥iÃҥӽФå¥ó¥]¬A¥þ³¡ªþ¥ó(¥Ó½Ð®Ñ½s¸¹¡GVEP-323/2010, VEP-334/2010, VEP-336/2011, VEP-346/2011, VEP-352/2012,
VEP-358/2012, VEP-360/2012, VEP-373/2012, VEP-377/2012, VEP-407/2013,
VEP-420/2013¤ÎVEP-439/2014);µn°O¥U¤ºªº¨ä¥L¬ÛÃö¤å¥ó¡F¥»³\¥iÃÒ©Ò»¡©úªº¸ê®Æ©Î½w¸Ñ±¹¬I¡F®Ú¾Ú¥»³\¥iÃÒ¤º¸üªº±ø¥ó¶·¦V¸pªø¦s©ñ©ÎÀò¸pªø§å㪺´£¥æ¤å¥ó©Ò«Øijªº½w¸Ñ±¹¬I¡F¥H¤Î¦b¤uµ{¶µ¥Ø¦U¶¥¬q¶i¦æªº«ùÄòºÊµø¤ÎºÊ¹î¤u§@©Ò«Øijªº½w¸Ñ±¹¬I¡Cµn°O¥U¤å¥ó©Òz«Øij¦p¨S¦³¦b¥»³\¥iÃÒ©ú½Tªí¥Ü¡A«h¤´¶·¹ê¬I³o¨Ç«Øij¡A°£«DÀò¥»³\¥iÃÒ©ú½TÁÅ°£©ÎÀq¥Ü×q¡C
1.8 All
deposited submissions, as required under this Permit, shall be rectified and
resubmitted in accordance with the comments, if any, made by the Director
within one month of the receipt of the Director¡¦s comments or otherwise as
specified by the Director.
©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó¡A¶·¦b±µÀò¸pªøªº·N¨£ (¦p¦³ªÌ) «á¤@Ӥ뤺 (°£«D¸pªø¥t¦æ«ü©w)¡A®Ú¾Ú¸pªøªº·N¨£¥[¥H×¥¿¨Ã¦A¦V¸pªø´£¥æ¡C
1.9
All submissions approved by the
Director, all submissions deposited without comments by the Director, and all
submissions rectified in accordance with comments by the Director under this
Permit shall be construed as part of the permit conditions described in Part C of this Permit. Any variation of the
submissions shall be approved by the Director in writing or as prescribed in
the relevant permit conditions. Any non-compliance with the submissions may
constitute a contravention of the Environmental Impact Assessment Ordinance
(Cap. 499).
¸pªø§å㪺©Ò¦³´£¥æ¤å¥ó¡B¸pªø¨S¦³µ¹¤©·N¨£ªº©Ò¦³¦s©ñ¤å¥ó¡B©Î®Ú¾Ú¥»³\¥iÃÒ³W©w¥Ñ¸pªøµ¹¤©·N¨£×¥¿ªº©Ò¦³´£¥æ¤å¥ó¡A§¡¶·¸àÄÀ¬°¥»³\¥iÃÒ C³¡»¡©úªº³\¥iÃÒ±ø¥óªº¤@³¡¤À¡C´£¥æ¤å¥ó¦p¦³¥ô¦ó×q¡A§¡¶·Àò¸pªøªº®Ñ±§åã¡A©Î²Å¦X¦³Ãö³\¥iÃÒ±ø¥óq©úªº³W©w¡C¦p¦³¤£²Å¦X´£¥æ¤å¥óªº±¡ªp¡A¥i¯à¹H¤ÏÀô¹Ò¼vÅTµû¦ô±ø¨Ò (²Ä499³¹) ªº³W©w¡C
1.10
All submissions or any variation of
the submissions shall be certified by the Environmental Team (ET) Leader and
verified by the Independent Environmental Checker (IEC) referred to in
Conditions 2.1 and 2.3 below, before submitting to the Director under this
Permit.
©Ò¦³´£¥æ¤å¥ó©Î´£¥æ¤å¥óªº¥ô¦ó×q¥»¡A§¡¶·¥Ñ«ö¤U¤å±ø¥ó²Ä2.1¤Î2.3¶µ©ÒzªºÀô¹Ò¤p²Õ²Õªø®ÖÃҤοW¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AµM«á¤~«ö¥»³\¥iÃÒ³W©w¦V¸pªø´£¥æ¡C
1.11
The Permit Holder shall release all
finalised submissions as required under this Permit, to the public by
depositing copies in the Environmental Impact Assessment Ordinance Register
Office, or in any other places, or any Internet websites as specified by the
Director, or by any means as specified by the Director, for public inspection.
For this purpose, the Permit Holder shall provide sufficient copies of the
submissions.
³\¥iÃÒ«ù¦³¤H¶·§â©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó©w½Z¤½¶}µ¹¤½²³¤H¤hª¾¹D¡A¤èªk¬O§â¦³Ãö¤å¥ó½Æ¥»¦s©ñ©óÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B¡A©Î¸pªø«ü©wªº¥ô¦ó¨ä¥L¦a¤è¡A©Î¸pªø«ü©wªº¥ô¦ó¤¬Ápºôºô¯¸¡A©Î±Ä¨ú¸pªø«ü©wªº¥ô¦ó¨ä¥L¤èªk¡A¥H¨Ñ¤½²³¬d¾\¡C¦]¦¹¡A³\¥iÃÒ«ù¦³¤H¶·´£¨Ñ¨¬°÷¼Æ¶qªº½Æ¥»¡C
1.12 All submissions
to the Director required under this Permit shall be delivered either in person
or by registered mail to the Environmental Impact Assessment Ordinance Register
Office (currently at 27/F, Southorn Centre, 130 Hennessy Road, Wanchai, Hong
Kong). Electronic copies of all finalised submissions required under this
Permit shall be prepared in Hyper Text Markup Language (HTML) (version 4.0 or
later) and in Portable Document Format (PDF) (version 1.3 or later), unless
otherwise agreed by the Director and shall be submitted at the same time as the
hardcopies.
¥»³\¥iÃÒ³W©w¦V¸pªø´£¥æªº©Ò¦³¤å¥ó¡A¶·¿Ë¨°e¥æ©Î¥H±¾¸¹¤è¦¡¶l±H¦ÜÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B (²{§}¬°¡G»´äÆW¥J°a¥§¸Ö¹D130¸¹×¹y¤¤¤ß27¼Ó)¡C©Ò¦³«ö¥»³\¥iÃÒ³W©w´£¥æªº¤å¥ó©w½Zªº¹q¤lª©¥»¡A°£«D¥tÀò¸pªø¦P·N¡A§¡¶·¥H¶W¤å¥»¼Ð¥Ü»y¨¥ (HTML) (²Ä4.0©Î¸û«áª©¥») ©M«KÄ⦡¤å¥ó®æ¦¡ (PDF) (²Ä1.3©Î¸û«áª©¥») »s§@¡A¨Ã¶·»Pµw½Æ¥»¦P®É´£¥æ¡C
1.13 The Permit Holder
shall notify the Director in writing the commencement date of construction of
the Project no later than one month prior to the commencement of construction
of the Project. The Permit Holder shall notify the Director in writing
immediately if there is any change of the commencement date of the
construction.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A¦Ü¤Ö´£¦¤@Ó¤ë¥H®Ñ±¤è¦¡§â«Ø³y¤uµ{ªº¬I¤u¤é´Á³qª¾¸pªø¡C¬I¤u¤é´Á¦p¦³¥ô¦ó§ó§ï¡A³\¥iÃÒ«ù¦³¤H¥²¶·¥ß§Y¥H®Ñ±¤è¦¡³qª¾¸pªø¡C
1.14 For the purpose
of this Permit, ¡§commencement of construction¡¨ does not include works related
to site clearance and preparation, or other works as agreed by the Director.
¬°°õ¦æ¥»³\¥iÃÒ¡A¡u¤uµ{¶µ¥Øªº®i¶}¡v¤£¥]¬A¦³Ãö¤u¦a²M²z©M¹w³Æªº¤uµ{¡A©Î¸pªø¦P·Nªº¨ä¥L¤uµ{¡C
1.15 The
Permit Holder shall notify the Director in writing the commencement date of
operation of the Project no later than two months prior to the commencement of operation
of the Project. The Permit Holder shall notify the Director in writing
immediately if there is any change of the commencement date of the operation.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥ØªºÀç¿ì¶}©l«e¡A¦Ü¤Ö´£¦¨âÓ¤ë¥H®Ñ±¤è¦¡§â¤uµ{ªº¶}©lÀç¿ì¤é´Á³qª¾¸pªø¡C¶}©lÀç¿ì¤é´Á¦p¦³¥ô¦ó§ó§ï¡A³\¥iÃÒ«ù¦³¤H¥²¶·¥ß§Y¥H®Ñ±¤è¦¡³qª¾¸pªø¡C
2 Special Conditions
¯S©w±ø¥ó
Employment of
Environmental Monitoring and Audit (EM&A) Personnel
¸u¥ÎÀô¹ÒºÊ¹î¤Î¼f®Ö(ÀôºÊ)¤Hû
2.1 An Environmental Team (ET) shall be established by the Permit Holder no
later than one month before the commencement of construction of the Project.
The ET shall not be in any way an associated body of the Independent
Environmental Checker (IEC) for the Project. The ET shall be headed by an ET
Leader. The ET Leader shall be a person who has at least 7 years of experience
in environmental monitoring and auditing (EM&A) or environmental
management.
¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ӥ릨¥ß¤@ÓÀô¹Ò¤p²Õ¡CÀô¹Ò¤p²Õ¤£±o»P¤uµ{¶µ¥Øªº¿W¥ßÀô¹Ò¬d®Ö¤H¦³¥ô¦óÁpô¡CÀô¹Ò¤p²Õ¶·¥Ñ¤@¦WÀô¹Ò¤p²Õ²Õªø±a»â¡CÀô¹Ò¤p²Õ²Õªø¶·¦bÀô¹ÒºÊ¹î¤Î¼f®Ö (ÀôºÊ) ©ÎÀô¹ÒºÞ²z¤è±¦Ü¤Ö¦³7¦~¸gÅç¡C
2.2 The
ET and the ET Leader shall be responsible for the implementation of the
EM&A programme in accordance with the EM&A requirements as contained in
the EM&A Manual of the Project. The ET Leader shall keep a contemporaneous
log-book of each and every instance or circumstance or change of circumstances,
which may affect the compliance with the recommendations of the EIA Report and
this Permit. The ET Leader shall notify the IEC within one working day of the
occurrence of any such instance or circumstance or change of circumstances. The
ET Leader¡¦s log-book shall be kept readily available for inspection by all
persons assisting in supervision of the implementation of the recommendations
of the EIA Report and this Permit or by the Director or his authorized
officers. Failure to maintain records in the log-book, failure to discharge the
duties of the ET Leader as defined in the EM&A Manual or failure to comply
with this Condition would entitle the Director to require the Permit Holder by
notice in writing to replace the ET Leader. Failure by the Permit Holder to
make replacement, or further failure to keep contemporaneous records in the
log-book despite the employment of a new ET Leader may render the Permit liable
to suspension, cancellation or variation.
Àô¹Ò¤p²Õ¤ÎÀô¹Ò¤p²Õ²Õªø¶·«öÀôºÊ¤â¥U¤º©Ò¸üªºÀôºÊ³W©w¡A°õ¦æÀôºÊp¹º¡CÀô¹Ò¤p²Õ²Õªø¶·«O¦s¤@¥»°O¿ý¥U¡A¦P®É°O¸ü¥i¯à·|¼vÅT²Å¦XÀôµû³ø§iªº«Øij¤Î¥»³\¥iÃÒªº±¡ªpªº¨C©v¨Æ¥ó¡B¨CºØ±¡ªp©Î¨C¦¸±¡ªpÅܤơCÀô¹Ò¤p²Õ²Õªø¶·¦bµo¥Í¥ô¦óÃþ¦ü¨Æ¥ó¡B±¡ªp©Î±¡ªpÅܤƫá¤@Ó¤u§@¤Ñ¤º³qª¾¿W¥ßÀô¹Ò¬d®Ö¤H¡C¦s©ñÀô¹Ò¤p²Õ²Õªøªº°O¿ý¥Uªº¦a¤è¡A¶·¥i¨Ñ¨ó§U·þ¾É°õ¦æÀôµû³ø§iªº«Øij¤Î¥»³\¥iÃÒªº©Ò¦³¤H¤h¡B¸pªø©ÎÀò±ÂÅv¤HûÀH®É¬d¾\¡CÀô¹Ò¤p²Õ²Õªø¦p¥¼¯à¦b°O¿ý¥U«O¦s°O¿ý¡B¥¼¯à°õ¦æÀôºÊ¤â¥U©Ò¦C©úªºÀô¹Ò¤p²Õ²Õªø¾°È©Î¥¼¯à²Å¦X¥»±ø¥óªº³W©w¡A¸pªø¦³Åv¥H®Ñ±n¨D³\¥iÃÒ«ù¦³¤HºM´«Àô¹Ò¤p²Õ²Õªø¡C³\¥iÃÒ«ù¦³¤H¦p¥¼¯à¦w±Æ¤H¿ï´À¸É¡A©Î¦b¸u¥Î·sÀô¹Ò¤p²Õ²Õªø«á¤´¥¼¯à¦b°O¿ý¥U«O¦s¦P´Áªº°O¿ý¡A¥i¾ÉP³\¥iÃÒ¾D¼È®É¦Q¾P¡B¨ú®ø©Î§ó§ï¡C
2.3 An Independent Environmental Checker (IEC) shall be employed by the
Permit Holder no later than one month before commencement of construction of
the Project. The IEC shall not be in any way an associated body of the
Contractor or the ET for the Project. The IEC shall be a person who has at
least 7 years of experience in EM&A or environmental management.
¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ó¤ë¸u¥Î¤@¦W¿W¥ßÀô¹Ò¬d®Ö¤H¡C¿W¥ßÀô¹Ò¬d®Ö¤H¤£±o»P¤uµ{¶µ¥Øªº©Ó¿ì°Ó©ÎÀô¹Ò¤p²Õ¦³¥ô¦óÁpô¡C¿W¥ßÀô¹Ò¬d®Ö¤H¶·¦bÀôºÊ©ÎÀô¹ÒºÞ²z¤è±¦Ü¤Ö¦³7¦~¸gÅç¡C
2.4
The IEC shall be responsible for duties defined
in the EM&A Manual and shall audit the overall EM&A performance,
including the implementation of all environmental mitigation measures,
submissions required in the EM&A Manual, and any other submissions required
under this Permit. In addition, the IEC shall be responsible for verifying the
environmental acceptability of permanent and temporary works, relevant design
plans and submissions under this Permit. The IEC shall verify the log-book(s)
mentioned in Condition 2.2 of this Permit. The IEC shall notify the Director by
fax, within one working day of receipt of notification from the ET Leader of
each and every occurrence, change of circumstances or non-compliance with the
EIA Report and/or this Permit, which might affect the monitoring or control of
adverse environmental impacts from the Project. In the case where the IEC fails
to so notify the Director of the same, fails to discharge the duties of the IEC
as defined in the EM&A Manual or fails to comply with this Condition, the
Director may require the Permit Holder by notice in writing to replace the IEC.
Failure to replace the IEC as directed or further failure to so notify the
Director despite employment of a new IEC may render the Permit liable to
suspension, cancellation or variation. Notification by the Permit Holder is the
same as notification by the IEC for the purpose of this Condition.
¿W¥ßÀô¹Ò¬d®Ö¤H¶·°õ¦æÀôºÊ¤â¥U©Ò¦C©úªºÂ¾°È¡A¥H¤Î¼f®Ö¾ãÅéÀôºÊ¤u§@ªºªí²{¡A¥]¬A¹ê¬I©Ò¦³Àô¹Ò½w¸Ñ±¹¬I¡B´£¥æÀôºÊ¤â¥U³W©wªº¤å¥ó¡A¥H¤Î´£¥æ¥»³\¥iÃÒ©Òn¨Dªº¨ä¥L¤å¥ó¡C¦¹¥~¡A¿W¥ßÀô¹Ò¬d®Ö¤H¶·®Ö¹ê¥Ã¤[¤ÎÁ{®É¤uµ{¦bÀô¹Ò¤Wªº¥i±µ¨üµ{«×¡B¬ÛÃöªº³]p¹Ï«h©M®Ú¾Ú¥»³\¥iÃÒ´£¥æªº¤å¥ó¡A¨Ã¶·®Ö¹ê¥»³\¥iÃÒ²Ä2.2¶µ±ø¥ó©Òzªº°O¿ý¥U¡C¦b¨C¦¸¥X²{¨Æ¬G©Î±¡ªp¡B©Î±¡ªpÅܤơB©Î¤£²Å¦XÀôµû³ø§i¤Î©Î¥»³\¥iÃÒªº±¡ªp¡A¦Ó¥i¯à·|§«Ãª¤uµ{¶µ¥Ø©Ò³y¦¨ªº¤£¨}Àô¹Ò¼vÅTªººÊ¹î©Î±±¨î¤u§@®É¡A¿W¥ßÀô¹Ò¬d®Ö¤H¶·¦b±µÀòÀô¹Ò¤p²Õ²Õªø³qª¾«á¤@Ó¤u§@¤Ñ¤º¥H¶Ç¯u¤è¦¡³qª¾¸pªø¡C¿W¥ßÀô¹Ò¬d®Ö¤H¦p¥¼¯à³qª¾¸pªø¦³Ãö±¡ªp¡A¥¼¯à°õ¦æÀôºÊ¤â¥U©Ò¦C©ú¿W¥ßÀô¹Ò¬d®Ö¤HªºÂ¾°È©Î¥¼¯à²Å¦X¥»±ø¥óªº³W©w¡A¸pªø¥i¥H®Ñ±n¨D³\¥iÃÒ«ù¦³¤HºM´«¿W¥ßÀô¹Ò¬d®Ö¤H¡C¦p¥¼¯à«ö«ü¥ÜºM´«¿W¥ßÀô¹Ò¬d®Ö¤H¡A©Î¦b¸u¥Î·s¿W¥ßÀô¹Ò¬d®Ö¤H«á¤´¥¼¯à³qª¾¸pªø¦³Ãö±¡ªp¡A«h©Î·|¾ÉP³\¥iÃÒ¾D¼È®É¦Q¾P¡B¨ú®ø©Î§ó§ï¡C¬°°õ¦æ¥»±ø¥ó¡A³\¥iÃÒ«ù¦³¤H§@¥Xªº³qª¾µ¥¦P¿W¥ßÀô¹Ò¬d®Ö¤H§@¥Xªº³qª¾¡C
2.5
All documents to be submitted or deposited as required under this Permit
shall be certified by the ET Leader
and verified by the IEC as conforming to the information, requirements and
recommendations set out in the EIA Report.
©Ò¦³«ö¥»³\¥iÃÒªºn¨D¦Ó´£¥æ©Î¦s©ñªº¤å¥ó¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø®ÖÃÒ¡A¨Ã¥Ñ¿W¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú¨ä²Å¦XÀôµû³ø§i©Ò¸ü¸ê®Æ¡B³W©w¤Î«Øij¡C
Management Organization of Main Construction
Companies
¥Dn«Ø³y¤½¥qªººÞ²z¬[ºc
2.6
The Permit Holder shall, no later than one month before the commencement of construction of the Project, inform the
Director in writing the management organization of the main construction
companies and/or any form of joint ventures associated with the construction of
the Project. The submitted information shall include at least an
organization chart, names of responsible persons and their contact details.
¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ó¤ë§â»P¤uµ{¶µ¥Øªº«Ø³y¤uµ{¬ÛÃöªº¥Dn«Ø³y¤½¥q¤Î / ©Î¥ô¦ó§Î¦¡ªº¦XÀç¥ø·~ªººÞ²z¬[ºc¡A¥H®Ñ±¤è¦¡³qª¾¸pªø¡C´£¥æªº¸ê®Æ¶·¦Ü¤Ö¥]¬A¤@¥÷²Õ´¹Ï¡Bt³d¤Hªº©m¦W¤ÎÁpµ¸¸ê®Æ¡C
Community Liaison
Groups
ªÀ°ÏÁpµ¸¤p²Õ
2.7 The
Permit Holder shall set up Community Liaison Groups comprising of
representatives from the relevant concerned and affected parties, including owners¡¦
corporations, management offices, local committees and schools of affected
areas, to facilitate communication, enquiries and complaints handling on all
environmental issues. The Permit Holder shall set up Community Liaison Groups
before the commencement of construction of the Project and maintain the
Community Liaison Groups up to the first 12 months of the operation of the
Project. The Permit Holder shall notify the Director the date of setting up the
Community Liaison Groups, the membership, the terms of reference and the
contact details.
³\¥iÃÒ«ù¦³¤H¶·¦¨¥ß¦hÓªÀ°ÏÁpµ¸¤p²Õ¡A¥Ñ¬ÛÃö¤Î¨ü¼vÅT¹ÎÅé¥Nªí²Õ¦¨¡A¥]¬A¨ü¼vÅT¦a°Ïªº·~¥D¥ß®×ªk¹Î¡BºÞ²z¤½¥q¡B¦a°Ï©eû·|¤Î¾Ç®Õ¡A¥H«K´N©Ò¦³Àô¹Ò°ÝÃD¥[±j»P¦³Ãö¤H¤hªº·¾³q¡A¤Î³B²z¦³Ãöªº¬d¸ß©M§ë¶D¡C³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{®i¶}«e¦¨¥ßªÀ°ÏÁpµ¸¤p²Õ¡A¨Ãºû«ù¸Óµ¥¤p²Õ¦Ü¤uµ{¶µ¥ØªºÀç¿ì¶}©l«áªºº12Ó¤ë¡C³\¥iÃÒ«ù¦³¤H¶·³qª¾¸pªøªÀ°ÏÁpµ¸¤p²Õªº½T¹ê¦¨¥ß¤é´Á¡B¦¨û¦W³æ¡B¾Åv½d³ò¤ÎÁpµ¸¸Ô±¡¡C
2.8 The Permit Holder shall set up a designated complaint hotline for the
Project to address the environmental concerns and complaints in an efficient
manner before the commencement of construction of the Project and maintain the
designated complaint hotline up to the first 12 months of the operation of the
Project.
³\¥iÃÒ«ù¦³¤H¶·¬°¤uµ{¶µ¥Ø³]¥ß¯S©w¹q¸Ü§ë¶D¼ö½u¡A¨³³t¦^À³¤Î³B²z¤½²³Ãöª`ªºÀô¹Ò¨Æ©y¤Î§ë¶D¡C¯S©w¹q¸Ü§ë¶D¼ö½u¶·¦b¤uµ{®i¶}«e¦¨¥ß¡A¨Ã¶·ºû«ù¹B§@¦Ü¤uµ{¶µ¥ØªºÀç¿ì¶}©l«áªºº12Ó¤ë¡C
Submission of Works
Schedule
´£¥æ¬I¤u®É¶¡ªí
2.9
The Permit Holder shall, no later than one month before the commencement of construction of the Project,
deposit with the Director a construction programme showing the commencement and
completion dates of major items of construction works, including dates of
taking possession of and subsequent exit from the works sites. The Permit
Holder shall inform the Director in writing in case of any subsequent changes
of items contained in this submitted construction programme.
¦b¤uµ{¶µ¥Øªº¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ó¤ë¦V¸pªø¦s©ñ¸Ô²Óªº¤uµ{¶µ¥Ø¬I¤u®É¶¡ªí¡C®É¶¡ªí¶·Åã¥Ü¦UºØ¥Dn¤uµ{¶µ¥Ø¤À¶µªº®i¶}¤Î§¹¤u¤é´Á¡A¨Ã¥]¬A¶i¦û¤Î°h¥X¤u¦a¤é´Á¡C¤w´£¥æªº¤uµ{¶µ¥Ø¬I¤u®É¶¡ªí¨ä«á¦p¦³¥ô¦ó¶µ¥Ø§ó§ï¡A³\¥iÃÒ«ù¦³¤H¥²¶·¥H®Ñ±¤è¦¡³qª¾¸pªø¡C
Measures to Mitigate
Ecological, Landscape and Visual Impact
¥ÍºA¡B´ºÆ[¤Îµøı¼vÅTªº½w¸Ñ±¹¬I
2.10
Before the commencement of any tunneling or soil excavation works, the
Permit Holder shall deposit with the Director an updated hydrogeological impact
assessment to reaffirm the findings of the EIA Report with respect to the
extent of the environmental impacts as a result of the potential hydrology and
groundwater level changes. Before, during and after the soil excavation or
tunneling works, the Permit Holder shall conduct groundwater level monitoring,
in particular in the ecologically sensitive areas, in consultation with
relevant stakeholders to verify the predictions in the EIA Report.
¦b®i¶}¥ô¦ó¶}«õÀG¹D©Î«õ¤g¤uµ{«e¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñ³Ì·sªº¦a¤U¤ô¤å¼vÅTµû¦ô¡A¥H½TÃÒÀôµû³ø§i¤º¦³Ãö¤ô¤å¤Î¦a¤U¤ô¦ì¼ç¦bÅܤƹïÀô¹Ò¼vÅTªºµ{«×ªº¬ã¨sµ²ªG¡C¦b«õ¤g©Î¶}«õÀG¹D¤uµ{¤§«e¡B´Á¶¡¤Î¤§«á¡A³\¥iÃÒ«ù¦³¤H¶·ºÊ¹î¦a¤U¤ô¦ì¡A¯S§O¬O¦b¥ÍºA©ö¨ü¯}Ãaªº¦a°Ï¡A¨Ã¿Ô¸ß¬ÛÃö¤H¤h©M¹ÎÅ骺·N¨£¡A¥H®Ö¹êÀôµû³ø§iªº¹w´úµ²ªG¡C
2.11
Before the commencement of any tunneling or soil excavation works, the
Permit Holder shall deposit with the Director a contingency plan to deal with
any unforeseeable incidents which might affect the groundwater level.
¦b®i¶}¥ô¦ó¶}«õÀG¹D©Î«õ¤g¤uµ{«e¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñºò«æÀ³ÅÜp¹º¡A¥H³B²z¥ô¦ó¥i¯à¼vÅT¦a¤U¤ô¦ì¦ýµLªk¹w¨£ªº¨Æ¬G¡C
2.12 The Permit Holder shall, no
later than one month before the commencement of construction at the respective
works areas of the Project, deposit with the Director the following submissions:
¦b¬ÛÃö¤u¦a®i¶}¤uµ{¶µ¥Øªº«Ø³y¤uµ{«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ó¤ë¦V¸pªø¦s©ñ¥H¤U¤å¥ó¡G
(i)
An Ecological Habitat Management Plan agreed by the Director of
Agriculture, Fisheries and Conservation. The Ecological Habitat Management Plan
shall contain the details of implementation schedule and construction programme
of the mitigated stream habitat to be provided in-situ within the works area of
the SSS and the ERS;
¸gº®¹A¦ÛµMÅ@²z¸p¸pªø¦P·Nªº¥ÍºAÀô¹ÒºÞ²zp¹º¡C¸Óp¹º¶·¸ü¦³¹ê¬I®É¶¡ªí¡A¥H¤Î¦b¥Û±^¦C¨®°±©ñ³B¤Î¥Û±^ºò«æ±Ï´©³B¤uµ{½d³ò¤ºì§}«Ø³y½w¸Ñªe¬y¥ÍºAÀô¹Òªºp¹º¸Ô±¡¡F
(ii)
A Monitoring and Emergency Response Plan agreed by the Director of
Agriculture, Fisheries and Conservation, in relation to potential impacts on
fishponds in Mai Po Area due to noise or vibration;
¸gº®¹A¦ÛµMÅ@²z¸p¸pªø¦P·N¡A¦³Ãö¦b¦Ì®H½d³òªº³½¶í¥i¯à¨ü¾¸µ©Î®¶°Ê³y¦¨ªº¼ç¦b¼vÅTªººÊ¹î¤Îºò«æÀ³ÅÜp¹º¡F
(iii)
A Vegetation Survey Report conducted for the magazine site at
¦b¤j¾ð¤U¦è¸ôªº¬µÃÄÜ®w¤u¦a¶i¦æªº´Óª«½Õ¬d³ø§i¡A¥H«K¬°¸Ó¤u¦a¨îq¦³®Äªº½w¸ÑºØ´Ó«Øij¡C
2.13 Vegetation
located within the Project site(s) shall be protected and preserved as far as
practicable. No more than 5,500 trees shall be felled. Detailed tree felling
application and compensatory planting proposal shall be submitted to seek
approval from other authorities.
¥Íªø©ó¤uµ{¶µ¥Ø¤u¦a¤ºªº´Óª«¶·¥[¥H«OÅ@¤ÎºÉ¶q«O¯d¡C¬å¥ïªº¾ð¤ì¤£±o¶W¹L5,500®è¡C¸Ô²Óªº¬å¥ï¾ð¤ì¥Ó½Ð¤Î¸ÉÀvºØ´Ó«Øij¶·´£¥æ¨ä¥L¦³Ãö·í§½§åã¡C
2.14
No later than one month before any tree felling, the Permit Holder shall
submit a Tree Planting and Landscape Plan, including the compensatory woodland,
in consultation with the Planning Department and Agriculture, Fisheries and
Conservation Department, for approval by the Director.
³\¥iÃÒ«ù¦³¤H¶·¿Ô¸ß³W¹º¸p¤Îº®¹A¦ÛµMÅ@²z¸pªº·N¨£¡A¨Ã¦b¬å¥ï¥ô¦ó¾ð¤ì«e¦Ü¤Ö¤@Ó¤ë¡A´£¥æ´Ó¾ð¤Î´ºÆ[¬ü¤Æp¹º¡A¥]¬A¸ÉÀv©Ê´ÓªLp¹º¡A¥H¨Ñ¸pªø§åã¡C
2.15 The Permit Holder shall
appoint a Certified Arborist for the Project to advise on, monitor and ensure
proper implementation of measures for protecting trees affected by the Project. Before the commencement of any work which may
affect any tree, the Permit Holders shall deposit with the Director a Tree
Protection Plan prepared by the Certified Arborist, detailing the requirements and measures for the proper
protection and monitoring of trees affected by the construction of the Project.
The Tree Protection Plan prepare by the Certified Arborist shall cover all
Project site(s) and shall include:
³\¥iÃÒ«ù¦³¤H¶·©e¥ô¤@¦W»{¥i¾ðÃÀ®v¡A¥H´N¤uµ{¶µ¥Ø´£¨Ñ·N¨£¡B¶i¦æºÊ¹î¤Î½T«O¦U¶µ«OÅ@¨ü¤uµ{¶µ¥Ø¼vÅTªº¾ð¤ìªº±¹¬I¯à§´µ½°õ¦æ¡C¦b¥ô¦ó¥i¯à¼vÅT¾ð¤ìªº¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñ¥Ñ»{¥i¾ðÃÀ®vÀÀ³Æªº¾ð¤ì«OÅ@p¹º¡A¸Ôz§´µ½«OÅ@¤ÎºÊ¹î¨ü¤uµ{¶µ¥Ø«Ø³y¤uµ{¼vÅTªº¾ð¤ìªº³W©w©M±¹¬I¡C¥Ñ»{¥i¾ðÃÀ®vÀÀ³Æªº¾ð¤ì«OÅ@p¹º¶·²[»\¤uµ{¶µ¥Øªº©Ò¦³¤u¦a¤Î¥]¬A¥H¤U¶µ¥Ø¡G
(i)
detailed working method
statement for the protection of trees;
¸Ô²Óªº«OÅ@¾ð¤ì§@·~¤èªk»¡©ú¡F
(ii)
tree transplanting proposal including final location for transplanted
trees that will be affected by the Project and are trees of high to medium
survival rate;
¾ð¤ì²¾´Ó«Øij¡A¥]¬A±N·|¨ü¤uµ{¶µ¥Ø¼vÅTªº¾ð¤ìªº³Ì²×²¾´Ó¦aÂI¡A¦Ó²¾´Ó¾ð¤ìªº¦s¬¡²v¶·¬°¤¤¦Ü°ª«×¡F
(iii)
compensatory tree planting
proposal including
location of trees to be planted as compensation to trees to be felled;
¸ÉÀv´Ó¾ð«Øij¡A¥]¬Ap¹º´Ó¾ðªº¦ì¸m¡A¥H¸ÉÀv³Q¬å¥ïªº¾ð¤ì¡F
(iv)
an audit report proposal on the tree protection activities to be
implemented throughout the construction period.
¼f®Ö³ø§i«Øij¡A¥H´N«Ø³y¤uµ{´Á¶¡¹ê¬Iªº«OÅ@¾ð¤ì¤u§@¶i¦æ¼f®Ö¡C
2.16 The Permit Holder shall
maintain continuous discussions with the West Kowloon Cultural District
Authority and in consultation with the Planning Department so as to further
refine the scale, location, disposition, design and integration strategies of
the ventilation shafts within the West Kowloon Cultural District to minimize
their visual impacts.
³\¥iÃÒ«ù¦³¤H¶·»P¦è¤EÀs¤å¤Æ°ÏºÞ²z§½Ä~Äò¶i¦æ½R°Ó¡A¨Ã¿Ô¸ß³W¹º¸p¡A¥H«K¶i¤@¨BÀu¤Æ¦è¤EÀs¤å¤Æ°Ï¤º³q·¤«ªº³W¼Ò¡B¦ì¸m¡B³W¹º¡B³]p¤Î¿Ä¦Xµ¦²¤¡A°È¨DºÉ¶q´î§C¹ïµøı³y¦¨ªº¼vÅT¡C
2.17 The Permit Holder
shall consult relevant government departments including Planning
Department on the reprovisioning and restoration of the public open space
affected by the Project. The Permit Holder shall, no later than two months
after the commencement of operation of the Project, deposit with the Director
the record of the public open space reprovisioning and restoration.
³\¥iÃÒ«ù¦³¤H¶·´N«¸m¤Î×´_¨ü¤uµ{¶µ¥Ø¼vÅTªº¤½²³¥ð¾Í¥Î¦a¼x¸ß³W¹º¸p¤Î¨ä¥L¦³Ãö¬F©²³¡ªùªº·N¨£¡C³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Ø¶}©lÀç¿ì«á¨âӤ뤺¡A¦V¸pªø¦s©ñ«¸m¤Î×´_¤½²³¥ð¾Í¥Î¦aªº°O¿ý¡C
Waste Management
¼oª«ºÞ²z
2.18
Inert construction and demolition (C&D) materials shall be separated
from non-inert C&D waste on site. The Permit Holder shall prohibit the
disposal of any C&D materials generated by the Project at the landfills,
with the exception of the non-inert C&D wastes and the small amount of
properly treated contaminated wastes.
´k©Ê©î«Øª«®Æ»P«D´k©Ê©î«Øª«®Æ¶·§@§Y³õ¤À¹j¡C³\¥iÃÒ«ù¦³¤H¶·¸T¤î¦³Ãö¤Hû¦b°ï¶ñ°Ï±ó¸m¤uµ{¶µ¥Ø²£¥Íªº¥ô¦ó©î«Øª«®Æ¡A¦ý«D´k©Ê©î«Øª«®Æ©M¤Ö¶q¸g§´µ½³B²zªº¨ü¦Ã¬V¼oª«°£¥~¡C
2.19 Inert
C&D materials shall be reused on site as far as possible, in order to
minimize the disposal of such materials to public fill reception facilities.
The Permit Holder shall deposit with the Director an updated C&D Material
Management Plan within three months of the commencement of the construction
works.
´k©Ê©î«Øª«®Æ¶·ºÉ¥i¯à§Y³õ´`Àô¨Ï¥Î¡AºÉ¶q´î¤Ö¹B©¹¤½²³¶ñ®Æ±µ¦¬³]¬Iªº¦³Ãöª«®Æ¶q¡C³\¥iÃÒ«ù¦³¤H¶·¦b«Ø³y¤uµ{®i¶}«áªº¤TӤ뤺¡A¦V¸pªø¦s©ñ³Ì·sªº©î«Øª«®ÆºÞ²zp¹º¡C
2.20 The Permit Holder shall control the disposal of C&D
materials through a trip ticket system. The Permit Holder shall take action to
restore any fly-tipping sites found to be dumped with C&D materials
generated by the Project.
³\¥iÃÒ«ù¦³¤H¶·§Q¥Î¹B¸ü°O¿ý¨î«×³WºÞ©î«Øª«®Æªº±ó¸m¡C¦pµo²{¤uµ{¶µ¥Ø²£¥Íªº©î«Øª«®Æ³Q¶ÉË©ó«ü©w¦aÂI¥~¡A³\¥iÃÒ«ù¦³¤H¶·±Ä¨ú¦æ°Ê¦^´_¶É˦aÂIªºì»ª¡C
2.21
The Permit Holder shall carry out further site
investigation regarding potential land contamination in accordance with the EIA
Report. Site inspection shall be carried out when individual site access is
granted to ascertain contaminative sources and hotspots of contamination. The
Permit Holder shall submit to the Director for approval a revised Contamination
Assessment Plan (CAP) with sampling and testing schedule updated based on
respective site condition. If contamination is found, the Permit
Holder shall submit to the Director
for approval a Remediation
Assessment Plan (RAP). No work on the identified potentially contaminated sites
shall be carried out unless and until the CAP and RAP submitted under this
condition are approved by the Director.
³\¥iÃÒ«ù¦³¤H¶·®Ú¾ÚÀôµû³ø§i´N¼ç¦bªº¤g¦a¦Ã¬V§@¶i¤@¨B¹ê¦a°É´ú¡C¹ê¦a°É´ú¶·©óÓ§O¤u¦a®e³\¶i¤J®É¶i¦æ¡A¥H½T©w¦Ã¬V·½ÀY©M¼öÂI¡C³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø´£¥æ¸g×qªº¦Ã¬Vµû¦ôp¹º¡A³s¦P¦]À³¬ÛÃö¦a½Lª¬ªp§@¥X§ó·sªº¨ú¼Ë¤Î´ú¸Õ§@·~ªí¡A¥H¨Ñ§åã¡C¦pµo²{¦Ã¬V±¡ªp¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø´£¥æ¸É±Ïµû¦ôp¹º¡A¥H¨Ñ§åã¡C¦³Ãö¤Hû¤£±o¦bÃѧO¬°¼ç¦b¨ü¦Ã¬V¤g¦a¶i¦æ¥ô¦ó¤uµ{¡Aª½¦Ü®Ú¾Ú¥»±ø¥ó´£¥æªº¦Ã¬Vµû¦ôp¹º¤Î¸É±Ïµû¦ôp¹ºÀò±o¸pªø§åã¡C
Concrete
Batching Facility at
°ªÅKÁ`¯¸¬I¤u°Ïªº²V¾®¤g°t®Æ³]³Æ
2.22 The
Permit Holder shall ensure that the haul road of the concrete batching facility
at West Kolwoon Terminus Works Area is entirely covered by water in accordance
with the application for variation of an environmental permit No. VEP-377/2012
and its attached documents at all times during working days of the West Kowloon
Terminus Works Area until the concrete batching facility is dismantled.
³\¥iÃÒ«ù¦³¤H¶·½T«O°ªÅKÁ`¯¸¬I¤u°Ï²V¾®¤g°t®Æ³]³Æªº¹B®Æ¸ô©ó°ªÅKÁ`¯¸¬I¤u°Ïªº¤u§@¤é¤º¥ô¦ó®É¶¡«ö·Ó§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-377/2012©M¸Ó¥Ó½Ðªºªþ¥ó§¹¥þ³Q¤ôÂл\¡Aª½¦Ü¸Ó²V¾®¤g°t®Æ³]³Æ³Q©î°£¡C
Measures
to Mitigate Construction Noise Impact
«Ø¿v¾¸µ¼vÅT½w¸Ñ±¹¬I
2.23 The
construction stage ground-borne noise impact at the time of tunnel boring
machine operation shall be monitored to confirm the ground-borne noise
levels. If it is envisaged that
the noise criteria will be exceeded at the nearby sensitive receivers, reducing
rotational speed and scheduling of works or other alternatives shall be adopted
to reduce noise impact in consultation with the affected parties.
¶·ºÊ´ú«Ø³y¶¥¬qÀG¹DÆp«õ¾÷¾Þ§@´Á¶¡©Ò²£¥Íªº¦a¼h¶Ç¾É¾¸µ¼vÅT¡A¥H½T©w¦a¼h¶Ç¾É¾¸µ¤ô¥¡C¦p¹wpªþªñ¾¸µ·PÀ³±jªº¦a¤èªº¾¸µ¤ô¥·|¶W¥X¼Ð·Ç¡A¶·»P¨ü¼vÅTªÌ°Óij¡A´îºCÆp«õ¾÷Âà³t¡B¦w±Æ¤uµ{®É¶¡©Î±Ä¥Î¨ä¥L´À¥N±¹¬I¡A¥H´î§C¾¸µ¼vÅT¡C
Measures to Mitigate Operational Ground-borne Noise Impact
Àç¿ì´Á¶¡¦a¼h¶Ç¾É¾¸µ¼vÅT½w¸Ñ±¹¬I
2.24 Within six months of
the commencement of the construction of the Project, the Permit Holder shall
deposit with the Director a Performance Test Plan for the verification of the
Line Source Response assumed in the EIA Report. The Performance Test Plan shall
include the result of the vibration borehole testing to be carried out at two
carefully selected locations along the tunnel alignment before the commencement
of the construction of the Project and the knowledge of the ground vibration
conditions to be obtained during the construction stage of the Project.
¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«áªº¤»Ó¤ë¤º¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñªí²{´ú¸Õp¹º¡A¥H®ÖÃÒÀôµû³ø§i©Ò±Ä¥Îªº½uª¬®¶·½¶Ç»¼©Ê¡Cªí²{´ú¸Õp¹º¶·¥]¬A«Ø³y¤uµ{®i¶}«eªuÀG¹D¨«綫¨â³B¤p¤ß¿ï¾Üªº¦a¤èªº®¶°ÊÆp¤Õ´ú¸Õªºµ²ªG¤Î¦b«Ø³y¤uµ{¤¤±o¨ìªº¦a¼h®¶°Ê±¡ªpª¾ÃÑ¡C
2.25 The Permit Holder shall
arrange testing of the Force Density Levels of the trains for the Project as
soon as possible, but in no case later than six months before the commencement
of operation of the Project.
³\¥iÃÒ«ù¦³¤H¶·ºÉ§Ö¡A¨Ã¤£±o¿ð©ó¤uµ{¶µ¥Ø¶}©lÀç¿ì«e¤»Ó¤ë¡A¦w±Æ¦C¨®ªº¤O±K«×¤ô¥´ú¸Õ¡C
2.26 Prior to the final
design of the trackform, the Permit Holder shall deposit with the Director an
updated ground-borne noise prediction report, with additional mitigation
measures as necessary, to demonstrate that the operation of the Project will be
within the predicted noise levels in the EIA Report.
¦b¸ôy³Ì²×³]p§¹¦¨«e¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñ¦³ÃöÀç¿ì¶¥¬qªº³Ì·s¦a¼h¶Ç¾É¾¸µ¹w´ú³ø§i¡A¨Ã¥]¬A©Ò»ÝÃB¥~½w¸Ñ±¹¬I¡AÃÒ©ú¨äÀç¿ì²Å¦XÀôµû³ø§i©Ò¸üªº¹w´ú¾¸µ¤ô¥¡C
2.27 The train operation
shall be confined within 0600 to 2400 hours daily with operation details given
below:
¦C¨®¹B§@®É¶¡¨î©ó¨C¤é¥Ñ0600®É¦Ü2400®É¡A¸Ô±¡¦p¤U:
Train Length |
Long
haul train: not more than 427m long Short
haul train: not more than 241m long |
Daily Operation |
Not
more than a total of 280 short haul trains and 66 long haul trains |
Operation Period
from 0700 to 2300 hours |
Hourly frequency: not more than 13 short haul and 4
long haul trains at northbound and not more than 12 short haul and 3 long
haul trains at southbound |
Operation Periods
of 0600 to 0700 hours and 2300 to 2400 hours |
Hourly
frequency: not more than 6 short haul trains at northbound and 6 short haul
trains at southbound; no long haul train movements in these periods. |
Train Speed |
Not
faster than 200 km/hr |
2.28 The following sections
of track shall be installed with low noise trackform in accordance with the EIA
report:
¥H¤U¸ô¬q¶·®Ú¾ÚÀôµû³ø§iªº«Øij¦w¸Ë§C¾¸µy¹D:
Chainage
(Southbound) Ãì¶Z(«n¦æ) |
Chainage
(Northbound) Ãì¶Z(¥_¦æ) |
||
From¥Ñ |
To¦Ü |
From¥Ñ |
To¦Ü |
123+040 |
123+640 |
123+050 |
123+650 |
133+160 |
133+660 |
133+170 |
133+670 |
137+600 |
138+350 |
137+620 |
138+370 |
139+100 |
139+600 |
139+120 |
139+620 |
140+900 |
141+600 |
140+900 |
141+600 |
2.29 The
Permit Holder shall maintain continuous discussion with the Housing Department
regarding the layout and foundation design of the future development at Site 6
in
¬°¤F¤é«á¦è¤EÀs²Ä¤»°Ïªºµo®i¤£·|¶W¹O¦a¼h¶Ç¾É¹w´ú¾¸µªº¤ô¥¡A³\¥iÃÒ«ù¦³¤H¶·»P©Ð«Î¸pÄ~Äò¶i¦æ½R°Ó¦³Ãö¸Ó¦a°Ï«Ø¿v§G§½¤Î¦a°òªº³]p¡C
2.30 The
Permit Holder shall maintain continuous discussion with the West Kowloon
Cultural District Authority regarding the future noise sensitive development in
the West Kowloon Cultural District to ensure the effectiveness of the provision
of low noise trackform at the terminus in
³\¥iÃÒ«ù¦³¤H¶·»P¦è¤EÀs¤å¤Æ°ÏºÞ²z§½Ä~Äò¶i¦æ½R°Ó¦³Ãö¦b¦è¤EÀs¤å¤Æ°Ïùتº¥¼¨Ó¾¸µ·PÀ³±jªº¦a¤è¡A¥H½T«O¦b¦è¤EÀsªºÁ`¯¸ªº§C¾¸µy¹Dªº®Ä¥Î¡C
2.31 Flexibility in the design for the
implementation of further noise mitigation measures including extending low
noise trackform to deal with any unforeseeable impact to any noise sensitive
receiver shall be allowed.
³]p¶·¨ã¼u©Ê¡A®e³\¹ê¬I¶i¤@¨Bªº¾¸µ½w¸Ñ±¹¬I¡A¥]¬A©µªø§C¾¸µy¹Dªº¸ô¬q¡A¥H³B²z¥ô¦ó¾¸µ·PÀ³±jªº¦a¤è¨ü¨ì¥ô¦óµLªk¹w¨£ªº¼vÅT¡C
Measures to Mitigate Noise Impact
from ERS and SSS
¥Û±^ºò«æ±Ï´©³B¤Î¥Û±^¦C¨®°±©ñ³B¾¸µ¼vÅT½w¸Ñ±¹¬I
2.32 Sound absorption
treatment shall be provided at the interior walls of the ERS. The treatment shall have a height of
¥Û±^ºò«æ±Ï´©³Bªº¤ºÀ𶷮ھÚÀôµû³ø§i§@§lµ³B²z¡A¦³Ãö³B²z³]¬I©ó¸ôy³»³¡¥H¤W
2.33 Noise barriers shall be
installed at the SSS in accordance with the application for variation of an
environmental permit No. VEP-377/2012 and its attached documents.
¶·®Ú¾Ú§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-377/2012©M¸Ó¥Ó½Ðªºªþ¥ó©ó¥Û±^¦C¨®°±©ñ³B¸Ë³]¹jµ«Ì»Ù¡C
2.34 Flexibility in the design for the
implementation of further noise mitigation measures including installation of additional
noise absorptive panels at the ERS and extension of noise barriers at the ERS
and the SSS to deal with any unforeseeable impact to any noise sensitive
receiver shall be allowed.
³]p¶·¨ã¼u©Ê¡A®e³\¹ê¬I¶i¤@¨Bªº¾¸µ½w¸Ñ±¹¬I¡A¥]¬A©ó¥Û±^ºò«æ±Ï´©³B¦w¸ËÃB¥~§lµªO¤Î©µªø¥Û±^ºò«æ±Ï´©³B¤Î¥Û±^¦C¨®°±©ñ³Bªº¹jµ«Ì»Ù¡A¥HÀ³¥I¥ô¦ó¾¸µ·PÀ³±jªº¦a¤è¨ü¨ì¥ô¦óµLªk¹w¨£ªº¼vÅT¡C
Measures to Mitigate Noise Impact from Ventilation Buildings
³q·¼Ó¾¸µ¼vÅT½w¸Ñ±¹¬I
2.35 The design of the
ventilation buildings shall comply with the maximum sound power levels
determined in the EIA Report, the amended pages of the EIA Report submitted in
accordance with the Approval Condition (8) and the applications for variation
of an environmental permit Nos. VEP-377/2012, VEP-407/2013, VEP439/2014 and
their attached documents. The noise emitted from the ventilation buildings
shall be free of the characteristics of tonality, impulsiveness and
intermittency.
³q·¼Ó³]p¶·²Å¦XÀôµû³ø§i¡A§åã±ø¥ó(8)©Ò´£¥æªº¸g×qªºÀôµû³ø§i¤À¶¤Î§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-377/2012,
VEP-407/2013, VEP439/2014©M¸Óµ¥¥Ó½Ðªºªþ¥ó©Ò©wªº³Ì°ªÁn¥\²v¯Å¡C³q·¼Óªº¾¸µ¶·¨S¦³µ½Õ¡B¯ß½Ä¤ÎÂ_Äò¯S¼x¡C
Noise Commissioning Test prior to Operation
¶}©lÀç¿ì«e´ú¸Õ
2.36 The Permit Holder
shall, no later than two weeks before the commencement of the operation of the
Project, deposit with the Director a Commissioning Test Report to confirm the
compliance of the operational air-borne and ground-borne noise levels in
accordance with the EIA Report and the application for variation of an
environmental permit No. VEP-377/2012 and its attached documents.
¦b¤£¤Ö©ó¤uµ{¶µ¥ØÀç¿ì¶}©l«e¨â¬P´Á¡A³\¥iÃÒ«ù¦³¤H¶·¦V¸pªø¦s©ñ¸Õ¦æ¹B§@´ú¸Õ³ø§i¡AÃÒ©ú¨ä²Å¦XÀôµû³ø§i¤Î§ó§ïÀô¹Ò³\¥iÃҥӽнs¸¹VEP-377/2012©M¸Ó¥Ó½Ðªºªþ¥ó¤º¸üªºÀç¿ì´Á¶¡¸gªÅ®ð¶Ç¾É¤Î¸g¦a¼h¶Ç¾Éªº¾¸µ¤ô¥¡C
Cultural
Heritage
¤å¤Æ¿ò²£
2.37 The Permit Holder shall, no later than one month
before the commencement of construction at the works area of SSS, Tai Kong Po
Emergency Access Point (TPP) or Tse Uk Tsuen (TUW), deposit with the Director
an Archaeological Action Plan agreed by the Antiquities and Monuments Office.
The Archaeological Action Plan shall include:
³\¥iÃÒ«ù¦³¤H¶·©ó¥Û±^¦C¨®°±©ñ³B¡B¤j¦¿®Hºò«æ±Ï´©¤J¤f©ÎÁ«Χø¤u¦a½d³òªº«Ø³y¤uµ{®i¶}«e¦Ü¤Ö´£¦¤@Ó¤ë¦V¸pªø¦s©ñ¸g¥jª«¥jÂÝ¿ì¨Æ³B¦P·Nªº¦Ò¥j¦æ°Êp¹º¡C¦³Ãöp¹º¶·¥]¬A:
(i)
a
detailed plan for further archaeological investigation at SSS and TPP;
¦b¥Û±^¦C¨®°±©ñ³B¤Î¤j¦¿®Hºò«æ±Ï´©¤J¤f¤u¦a½d³ò§@¶i¤@¨B¦Ò¥j°É¬dªº¸Ô²Óp¹º;
(ii)
a
detailed plan for rescue excavation at the southern portion of SSS;
¦b¥Û±^¦C¨®°±©ñ³B¤u¦a½d³òªº«n±³¡¤À§@·m±Ïµo±¸ªº¸Ô²Óp¹º;
(iii)
a
contingency plan to address possible arrangement when significant
archaeological findings are unearthed during the further archeological
investigation and rescue excavation; and
¨îqÀ³ÅÜp¹º¡AÀ³¥I·í¶i¤@¨B¦Ò¥j°É¬d¤Î·m±Ïµo±¸¶i¦æ´Á¶¡¦³«¤j¦Ò¥jµo²{®Éªº¥i¯à¦w±Æ; ¥H¤Î
(iv)
a
detailed plan for Archaeological Watching Brief for the identification of any
historical finds during the construction works at TUW.
¨îq¦Ò¥jÆ[´úºKnªº¸Ô²Óp¹º¡A¥HÃѧO¦bÁ«Χø¤u¦a½d³ò¶i¦æ«Ø³y¤uµ{´Á¶¡ªº¥ô¦ó¾ú¥vµo²{¡C
2.38 The
Permit Holder shall appoint a licensed Archaeologist to conduct the further
archeological investigation in the works area at SSS and TPP, to conduct rescue
excavation to preserve any archaeological remains, and to undertake the
Archaeological Watch Brief in the works area at TUW in accordance with the EIA
Report.
³\¥iÃÒ«ù¦³¤H¶·©e¥ô«ùµP¦Ò¥j¾Ç®a¡A®Ú¾ÚÀôµû³ø§i¦b¥Û±^¦C¨®°±©ñ³B¤Î¤j¦¿®Hºò«æ±Ï´©¤J¤f¤u¦a½d³ò§@¶i¤@¨B¦Ò¥j°É¬d¡B¶i¦æ·m±Ïµo±¸¥H«O¦s¥ô¦ó¦Ò¥j¿òª«¡A¥H¤Î©Ó¾á¦bÁ«Χø¤u¦a½d³òªº¦Ò¥jÆ[´úºKnªº¤u§@¡C
2.39 Before
the commencement of any tunneling work which may affect the ex-Lai Chi Kok
Hospital, the Permit Holder shall consult the Antiquities and Monuments Office
and other relevant parties on the installation of vibration monitoring device
for the ex-Lai Chi Kok Hospital.
¦b®i¶}¥ô¦ó¥i¯à¼vÅT«e¯ïªK¨¤Âå°|ªº¶}±¸ÀG¹D¤uµ{«e¡A³\¥iÃÒ«ù¦³¤H¶·´N©ó«e¯ïªK¨¤Âå°|¦w¸Ë®¶°ÊºÊ¹î¸Ë¸m¡A¼x¸ß¥jª«¥jÂÝ¿ì¨Æ³B¤Î¨ä¥L¦³Ãö¹ÎÅ骺·N¨£¡C
Stockpiling of Materials at To Kau
Wan Works Area
¦b˦©ÆWª«®Æ¦s©ñ³B°ï¦sª«®Æ
2.40 The Permit Holder
shall ensure that the To Kau Wan Works Area is only
used for proper stockpiling of fill materials generated from the Project
suitable for use by the Hong Kong - Zhuhai -
³\¥iÃÒ«ù¦³¤H¶·½T«O˦©ÆWª«®Æ¦s©ñ³B¥u¥i«ê·í¦a¥Î§@°ï¦s¥Ñ¤uµ{¶µ¥Ø²£¥Í¡A¾A¦X´ä¯]¿D¤j¾ô¤uµ{¿ì¨Æ³B¨Ï¥Îªº¶ñ®Æ¡C°ï¦sª«®Æªº°ª«×¤£±o°ª©ó¦a±8¦Ì¡C°ï¦sª«®Æªº¼Æ¶q¤£±o¦h©ó350,000¥ß¤è¦Ì¡C
2.41 The
Permit Holder shall continue to operate the To Kau Wan Works Area until the
works area together with the stockpiled materials is allocated to the Hong Kong - Zhuhai -
³\¥iÃÒ«ù¦³¤H¶·«ùÄòÀç¿ì˦©ÆWª«®Æ¦s©ñ³B¡Aª½¦Ü¸Óª«®Æ¦s©ñ³B³s¦P°ï¦sªºª«®Æ³Q´ä¯]¿D¤j¾ô¤uµ{¿ì¨Æ³B±µºÞ¬°¤î¡C
2.42 The
Permit Holder shall, no later than one month before the commencement of
construction at the To Kau Wan Works Area, deposit with the Director a
landscape plan prepared for the works area. The landscape plan shall include the design details,
implementation schedule, and drawings in appropriate scale showing the
landscape and visual mitigation measures.
¦b˦©ÆWª«®Æ¦s©ñ³Bªº«Ø³y¤uµ{®i¶}«e¡A³\¥iÃÒ«ù¦³¤H¶·¦Ü¤Ö´£¦¤@Ó¤ë¦V¸pªø¦s©ñ¬°¸Óª«®Æ¦s©ñ³BÀÀ³Æªº´ºÆ[¬ü¤Æp¹º¡C´ºÆ[¬ü¤Æp¹º¶·¥]¬A³]p¸Ô±¡¡B¹ê¬I®É¶¡ªí¤Î¦X¾A¤ñ¨Òªº¹Ï«h¡AÅã¥Ü´ºÆ[¤Îµøı½w¸Ñ±¹¬I¡C
North
Launching Shaft and Tse
¥Û±^¤C¬P±^¶}«õÀG¹D¤J¤f½Ý¤«¤ÎÁ«Χø«Ø¿v½Ý¤«
2.43 The Permit Holder shall ensure that each
blast shall be covered by a steel cage and confined with gunny sackings, wire
mesh and sand bags, a sprinkler system, and a canvas cover (PVC screen). The set up of each blast shall be
certified by an Independent Checking Engineer and a Blasting Competent Person,
and shall be approved by Mines Division of the Civil Engineering and
Development Department prior to commencement of the blasting activities.
³\¥iÃÒ«ù¦³¤H¶·½T«O¨C¦¸Ãz¯}¶·¥H¿ûÅ¢Âл\¥H¤Î¥Î³Â¥]³U¡BÅKµ·ºô¤Î¨F¥]¡BÅx¤ô¨t²Î¤Î¦|¥¬»\(»E´â¤A²m»\)¥]³ò¡C¨C¦¸Ãz¯}¶·¸g¥Ñ¿W¥ß½]®Ö¤uµ{®v¤Î¦X¸ê®æ¤H¤h©Ò»{¥i¡A¤Î©óÃz¯}¬¡°Ê¶}©l¤§«e¸g¥Ñ¤g¤ì¤uµ{©Ý®i¸pÄq°È³¡§åã¡C
Obstruction
Removal Works at Sham Shui Po New Ferry Pier at
¦b«n©÷²`¤ô埗·s½XÀYªº»Ùꪫ²¾°£¤uµ{
2.44 The Permit Holder shall monitor the types and
quantities of wastes that would be generated from the obstruction removal works
at Sham Shui Po New Ferry Pier to confirm the assessment result for the
works. If any marine sediment is
encountered, the Permit Holder shall ensure the disposal in accordance with the
updated C&D Material Management Plan under Condition 2.19.
³\¥iÃÒ«ù¦³¤H¶·ºÊ¹î¦b²`¤ô埗·s½XÀYªº»Ùꪫ²¾°£¤uµ{©Ò²£¥Íªº¼oª«Ãþ«¬¤Î¼Æ¶q¡A¥H½T©w¸Ó¤uµ{ªºµû¦ôµ²ªG¡CYµo²{¥ô¦ó®ü牀©³ªd¡A³\¥iÃÒ«ù¦³¤H¶·½T«O¨ä±ó¸m²Å¦X±ø¥ó2.19ªº³Ì·sªº©î«Øª«®ÆºÞ²zp¹º¡C
Environmental
Monitoring and Audit (EM&A) Requirements
Àô¹ÒºÊ¹î¤Î¼f®Ö(ÀôºÊ)³W©w
2.45 The Permit Holder shall implement the EM&A programme in accordance
with the procedures and requirements as set out in the EM&A Manual. Any
changes to the programme shall be justified by the ET Leader and verified by
the IEC as conforming to the information and requirements contained in the
EM&A Manual before submission to the Director for approval.
³\¥iÃÒ«ù¦³¤H¶·«öÀôºÊ¤â¥U©Ò¸üªºµ{§Ç¤Î³W©w°õ¦æÀôºÊp¹º¡Cp¹º¦p¦³¥ô¦ó§ó§ï¡A¶·¥ÑÀô¹Ò¤p²Õ²Õªø´£¥X¥R¤À²z¥Ñ¡A¨Ã¥Ñ¿W¥ßÀô¹Ò¬d®Ö¤H®Ö¹ê¡AÃÒ©ú¨ä²Å¦XÀôºÊ¤â¥U©Ò¸ü¸ê®Æ¤Î³W©w¡A¤è¥i´£¥æ¸pªø§åã¡C
2.46 Samples, measurements and necessary remedial actions shall be taken in accordance
with the requirements of the EM&A Manual by:
¨ú¼Ë¡B´ú¶q¤Î±Ä¨ú©Ò»Ýªº¸É±Ï¦æ°Ê¡A§¡¶·«ö·ÓÀôºÊ¤â¥Uªº³W©w¶i¦æ¡G
(a)
conducting baseline environmental monitoring;
¶i¦æÀô¹Ò°ò½uºÊ¹î¡F
(b)
conducting impact monitoring;
¶i¦æ¼vÅTºÊ¹î¡F
(c)
carrying out remedial actions described in
Event/Action Plans of the EM&A Manual in accordance with the time frames
set out in Event/Action Plans, or as agreed by the Director, in case where
specified criteria in the EM&A Manual are exceeded; and
¦p¶W¹OÀôºÊ¤â¥U¤º«ü©wªº¼Ð·Ç¡A«h«ö·ÓÀôºÊ¤â¥U¤ºªº¨Æ¥ó/¦æ°Êp¹º©Òq©úªº®É©Î¸pªø©Ò¦P·Nªº®É¡A°õ¦æ¨Æ¥ó/¦æ°Êp¹º©Ò»¡©úªº¸É±Ï¦æ°Ê¡F¥H¤Î
(d)
logging and keeping records of details of (a)
to (c) above for all parameters within 3 working days of collection of data or
completion of remedial action(s), for the purpose of preparing and submitting
the monthly EM&A Reports and to make available for inspection on site.
¦b¦¬¶°¼Æ¾Ú©Î§¹¦¨¸É±Ï¦æ°Êªº3Ó¤u§@¤Ñ¤º¡A¶·°O¿ý¤Î³Æ¦s¤W¤å(a) ¦Ü(c)¶µ¦U°Ñ¼Æªº¸Ô±¡¡A¥Î§@ÀÀ³Æ¨Ã´£¥æ¨C¤ëÀôºÊ³ø§i¡A¨Ã³Æ§´¦³Ãö¸ê®Æ¥H¨Ñ¦b¤u¦a¬d¾\¡C
2.47 The Permit Holder shall deposit with the Director six hard copies and one electronic copy of
the Baseline Monitoring Report at least one month before commencement of
construction of the Project. Additional copies of the submission shall be made
available to the Director upon his request.
¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«e¡A¶·¦Ü¤Ö´£¦¤@Ó¤ë¦V¸pªø´£¥æ°ò½uºÊ¹î³ø§iªº¤»¥÷µw½Æ¥»¤Î¤@¥÷¹q¤lª©¥»¡C¦p¸pªøn¨D¡A«h¶·´£¥æÃB¥~½Æ¥»¡C
2.48 The Permit Holder shall deposit with the Director six hard copies and one electronic copy of
monthly EM&A Report within 10 working days after the end of the reporting
month. The EM&A Reports shall include a summary of all non-compliance
(exceedances) of the environmental quality performance limits (Action and Limit
Levels). A summary and progress update of the Project
Implementation Schedule (Table 18.1 of the EIA Report) shall also be included
in each EM&A Report. Additional copies of the
submission shall be provided to the Director upon request by the Director.
¦b³W©w´£¥æ³ø§iªº¤ë¥÷µ²§ô«á10Ó¤u§@¤Ñ¤º¡A¶·¦V¸pªø´£¥æ¨C¤ëÀôºÊ³ø§iªº¤»¥÷µw½Æ¥»¤Î¤@¥÷¹q¤lª©¥»¡CÀôºÊ³ø§i¶·¥]¬A¦UºØ¤£²Å¦X¡]¶W¥X¡^Àô¹Ò½è¯Àªí²{³W¡]¦æ°Ê¤Î·¥¤ô¥¡^±¡ªpªººKn¡C©Ò¦³ÀôºÊ³ø§i¶·¥]¬A¤uµ{¶µ¥Ø¹ê¬I¦w±Æ(Àôµû³ø§iªí18.1)ªººKn¤Î¶i«×§ó·s¡C¦p¸pªøn¨D¡A«h¶·´£¥æÃB¥~½Æ¥»¡C
2.49 The Permit Holder shall, no
later than three months after the commencement of operation of the Project, deposit with the Director an Environmental
Monitoring and Audit report on the implementation of the mitigation measures
for operation stage of the Project in accordance with the EIA Report and the submissions
required under of this Permit.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥ØªºÀç¿ì¶}©l«á¤TӤ뤺¦V¸pªø´£¥æÀôºÊ³ø§i¡A³ø§i«ö·ÓÀôµû³ø§i¤Î¥»³\¥iÃÒn¨D¦Ó´£¥æªº¤å¥ó©ó¤uµ{Àç¿ì¶¥¬qªº½w¸Ñ±¹¬Iªº¹ê¬I±¡ªp¡C
Electronic Reporting
¹q¤l¶×³ø
2.50 To
facilitate public inspection of the documents to be submitted or deposited as
required under this Permit, the Baseline Monitoring Report and EM&A Reports
via the Environmental Impact Assessment Ordinance Internet Website and at the
Environmental Impact Assessment Ordinance Register Office, the Permit Holder shall prepare electronic copies of these documents and
Reports in Hyper Text Markup Language (HTML) (version 4.0 or later) and in
Portable Document Format (PDF) (version 1.3 or later) or other format agreed by
the Director, and shall submit the electronic copies at the same time as the
hardcopies. For the HTML version, a content page capable of providing hyperlink
to each section and sub-section of these documents and Reports shall be
included in the beginning of the document. Hyperlinks to all figures, drawings
and tables in these documents and Reports shall be provided in the main text
from where the respective references are made. All graphics in these documents
and Reports shall be in interlaced GIF format unless otherwise agreed by the
Director. The content of the electronic copies of these documents and Reports
must be the same as the hardcopies.
¬°¤è«K¤½²³³z¹LÀô¹Ò¼vÅTµû¦ô±ø¨Ò¤¬Ápºôºô¯¸¤Î¦bÀô¹Ò¼vÅTµû¦ô±ø¨Òµn°O¥U¿ì¨Æ³B¬d¾\«ö·Ó¥»³\¥iÃÒªºn¨D¦Ó´£¥æ©Î¦s©ñªº¤å¥ó¡B°ò½uºÊ¹î³ø§i¤Î¨C¤ëÀôºÊ³ø§i¡A³\¥iÃÒ«ù¦³¤H¶·¥H¶W¤å¥»¼Ð¥Ü»y¨¥¡]HTML¡^¡]²Ä4.0©Î¸û«áª©¥»¡^¤Î«KÄ⦡¤å¥ó®æ¦¡¡]PDF¡^¡]²Ä1.3©Î¸û«áª©¥»¡^©Î¨ä¥LÀò¸pªø¦P·Nªº®æ¦¡¡A»s§@¤å¥ó¤Î³ø§iªº¹q¤lª©¥»¡A»Pµw½Æ¥»¦P®É´£¥æ¡CÃö©óHTMLªºª©¥»¤è±¡A¥i»P¤å¥ó¤Î³ø§i¦U¸`¤Î¤p¸`§@¥X¶W¤å¥»³sµ²ªº¥Ø¿ý¶·¦b¤å¥ó¶}ºÝ¥[¤J¡C¤å¥ó¤Î³ø§i¤º¦UÃþ¹Ïªí¶·¦b¸ü¦³¬ÛÃö¸ê®Æªº¥¿¤å¤º§@¥X¶W¤å¥»³sµ²¡C°£«D¥tÀò¸pªø¦P·N¡A¤å¥ó¤Î³ø§i¤º©Ò¦³¹Ï§Î§¡¶·¥H¥æ¿ù¦s¨úªºGIF®æ¦¡¨î©w¡C¤å¥ó¤Î³ø§iªº¹q¤lª©¥»¤º®e¡A¥²¶·»Pµw½Æ¥»ªº¤º®e¤@P¡C
2.51 The Permit
Holder shall set up a dedicated Internet website and notify the Director in
writing the Internet address where the environmental monitoring and project
data are to be placed, within six weeks after the commencement of construction
of the Project. All environmental monitoring data described in Conditions 2.45
to 2.49 above shall be made available to the public via a dedicated Internet
website to be set up by the Permit Holder in the shortest possible time and in
no event later than 2 weeks after the relevant environmental monitoring data
are collected or become available, unless otherwise agreed with the Director.
³\¥iÃÒ«ù¦³¤H¶·¦b¤uµ{¶µ¥Øªº«Ø³y¤uµ{®i¶}«á¤»Ó¬P´Á¤º¡A³]¥ß¯S©w¤¬Ápºôºô¯¸¦s©ñÀô¹ÒºÊ¹î¼Æ¾Ú¤Î¤uµ{¶µ¥Ø¸ê®Æ¡A¨Ã¥H®Ñ±³qª¾¸pªø¤¬Ápºôºô§}©Ò¦b¡C¤W¤å±ø¥ó²Ä2.45¦Ü2.49¶µ»¡©úªº©Ò¦³Àô¹ÒºÊ¹î¼Æ¾Ú¡A°£«D¥tÀò¸pªø¦P·N¡A§¡¶·ºÉ§Ö³z¹L¥Ñ³\¥iÃÒ«ù¦³¤H³]¥ßªº¯S©w¤¬Ápºôºô¯¸¨Ñ¤½²³¾\Äý¡A¦b¥ô¦ó±¡ªp¤U§¡¤£±o¿ð©ó¦³ÃöÀô¹ÒºÊ¹î¼Æ¾Úªº¦¬¶°©Î¥i¨Ñ¾\Äý«áªº2Ó¬P´Á¡C
2.52 The Internet website as described in
Condition 2.51 above shall enable user-friendly public access to the monitoring
and project data including the EIA Report, the amended pages of the EIA Report
submitted in accordance with the Approval Condition (8), the environmental
permit(s) and the project profile of the Project. Unless otherwise agreed with
the Director, the Internet website shall have features capable of:
¤W¤å±ø¥ó²Ä2.51¶µ»¡©úªº¤¬Ápºôºô¯¸¡A¥²¶·¤è«K¥Î¤á¨Ï¥Î¡AÅý¤½²³®e©ö±µ¹FÀô¹ÒºÊ¹î¼Æ¾Ú¤Î¤uµ{¶µ¥Ø¸ê®Æ¡A·í¤¤¥]¬A¤uµ{¶µ¥ØªºÀôµû³ø§i¡B®Ú¾Ú§åã±ø¥ó(8)¦Ó´£¥æªº¸g×qªº¤À¶¡BÀô¹Ò³\¥iÃҤΤuµ{¶µ¥Ø²¤¶¡C°£«D¥tÀò¸pªø¦P·N¡A¤¬Ápºôºô¯¸¶·¨ã³Æ³¡¥ó¡A´£¨Ñ¤Uz¥\¯à¡G
(a)
providing access to all
environmental monitoring data collected since the commencement of works;
±µ¹F¤uµ{®i¶}«á©Ò¦¬¶°ªº¥þ³¡Àô¹ÒºÊ¹î¼Æ¾Ú¡F
(b)
searching by date;
«ö¤é´Á·j´M¡F
(c)
searching by types of
monitoring data (noise, water and air quality); and
«öºÊ¹î¼Æ¾ÚÃþ§O¡]¾¸µ¡B¤ô½è¤ÎªÅ®ð½è¯À¡^·j´M¡F¥H¤Î
(d)
hyperlinks to relevant
monitoring data after searching.
¦b·j´M«á»P¬ÛÃöªººÊ¹î¼Æ¾Ú§@¥X¶W¤å¥»³sµ²¡C
Notes :
µù¡G
1.
This Permit consists of
three parts, namely, PART A
(Main Permit), PART B
(Description of Designated Project) and PART C (Permit Conditions). Any person
relying on this permit should obtain independent legal advice on the legal
implications under the Ordinance, and the following notes are for general
information only.
¥»³\¥iÃÒ¦@¦³¤TÓ³¡¤À¡A§YA³¡¡]³\¥iÃÒ¥Dn³¡¤À¡^¡FB³¡¡]«ü©w¤uµ{¶µ¥Øªº»¡©ú¡^¤ÎC³¡¡]³\¥iÃÒ±ø¥ó¡^¡C¥ô¦ó´©¤Þ¥»³\¥iÃÒªº¤H¤h¶·´N±ø¨Òªºªk«ß§t·N¼x¸ß¿W¥ßªk«ß·N¨£¡A¤Uzµù¸Ñ¥u¨Ñ¤@¯ë°Ñ¦Ò¥Î¡C
2.
If there is a breach of any
conditions of this Permit, the Director or his authorized officer may, with the
consent of the Secretary for the Environment, order the cessation of associated
work until the remedial action is taken in respect of the resultant
environmental damage, and in that case the Permit Holder shall not carry out
any associated works without the permission of the Director or his authorized
officer.
¦p¹H¤Ï¥»³\¥iÃÒªº¥ô¦ó±ø¥ó¡A¸pªø©ÎÀò±ÂÅv¤Hû¥i¦bÀô¹Ò§½§½ªøªº¦P·N¤U°Ç¥O°±¤î¬ÛÃö¤uµ{¡Aª½¦Ü³\¥iÃÒ«ù¦³¤H¬°©Ò³y¦¨ªºÀô¹Ò·l®`±Ä¨ú¸É±Ï¦æ°Ê¬°¤î¡C¦b¦¹±¡ªp¤U¡A³\¥iÃÒ«ù¦³¤H¥¼¸g¸pªø©ÎÀò±ÂÅv¤Hû¦P·N¡A¤£±o¶i¦æ¥ô¦ó¬ÛÃö¤uµ{¡C
3.
The Permit Holder may apply
under Section 13 of the Ordinance to the Director for a variation of the
conditions of this Permit. The Permit Holder shall replace the original
permit displayed on the Project site(s) by the amended permit.
³\¥iÃÒ«ù¦³¤H¥i®Ú¾Ú±ø¨Ò²Ä13±øªº³W©w¦V¸pªø¥Ó½Ð§ó§ï¥»³\¥iÃÒªº±ø¥ó¡C³\¥iÃÒ«ù¦³¤H¶·§â¸gק諸³\¥iÃÒ´À´«¦b¤u¦a¤º®i¥Üªºì¦³³\¥iÃÒ¡C
4.
A person who assumes the
responsibility for the whole or a part of the designated project may, before
the person assumes responsibility of the designated project, apply under
Section 12 of the Ordinance to the Director for a further environmental permit.
©Ó¾á«ü©w¤uµ{¶µ¥Ø¾ã¶µ©Î³¡¤À¤uµ{ªº³d¥ôªº¤H¡A¦b©Ó¾á³d¥ô¤§«e¡A¥i®Ú¾Ú±ø¨Ò²Ä12±øªº³W©w¦V¸pªø¥Ó½Ð·sªºÀô¹Ò³\¥iÃÒ¡C
5.
Under Section 14 of the
Ordinance, the Director may with the consent of the Secretary for the Environment,
suspend, vary or cancel this Permit. The suspended, varied or cancelled
Permit shall be removed from display at the Project site(s).
®Ú¾Ú±ø¨Ò²Ä14±øªº³W©w¡A¸pªø¥i¦bÀô¹Ò§½§½ªøªº¦P·N¤U¼È®É¦Q¾P¡B§ó§ï©Î¨ú®ø¥»³\¥iÃÒ¡C¾D¼È®É¦Q¾P¡B§ó§ï©Î¨ú®øªº³\¥iÃÒ¥²¶·±q¤u¦aªº®i¥Ü¦aÂI°£¤U¡A¤£¦A®i¥Ü¡C
6.
If this Permit is cancelled
or surrendered during construction or operation of the Project, another
environmental permit must be obtained under the Ordinance before the Project
could be continued. It is an offence under section 26(1) of the Ordinance
to construct or operate a designated project listed in Part I of schedule 2 of
the Ordinance without a valid environmental permit.
¦pªG¥»³\¥iÃÒ¦b¤uµ{¶µ¥Ø«Ø³y©ÎÀç¿ì´Á¶¡¨ú®ø©Î¥æ¦^¡A«h¦bÄ~Äò¶i¦æ¤uµ{¶µ¥Ø¤§«e¡A¥²¶·¥ý®Ú¾Ú±ø¨Ò³W©w¨ú±o¥t¤@¥÷Àô¹Ò³\¥iÃÒ¡C®Ú¾Ú±ø¨Ò²Ä26(1)±øªº³W©w¡A¥ô¦ó¤H¦b¨S¦³¦³®ÄÀô¹Ò³\¥iÃÒªº±¡ªp¤U«Ø³y©ÎÀç¿ì±ø¨Òªþªí2²ÄI³¡©Ò¦C©úªº«ü©w¤uµ{¶µ¥Ø¡A§YÄݥǸo¡C
7.
Any person who constructs
or operates the Project contrary to the conditions in the Permit, and is
convicted of an offence under the Ordinance, is liable:-
¦p¥ô¦ó¤H¦b¹H¤Ï¥»³\¥iÃÒªº±ø¥ó¤U«Ø³y©ÎÀç¿ì¤uµ{¶µ¥Ø¡A®Ú¾Ú±ø¨Ò¡A§YÄݥǸo ¡V
(i)
on a first conviction on
indictment to a fine of $ 2 million and to imprisonment for 6 months;
¤@¸g´`¤½¶Dµ{§Çº¦¸©w¸o¡A¥i³B»@´Ú200¸U¤¸¤ÎºÊ¸T6Ó¤ë¡F
(ii)
on a second or subsequent
conviction on indictment to a fine of $ 5 million and to imprisonment for 2
years;
¤@¸g´`¤½¶Dµ{§Ç²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú500¸U¤¸¤ÎºÊ¸T2¦~¡F
(iii)
on a first summary
conviction to a fine at level 6 and to imprisonment for 6 months;
¤@¸g´`²©öµ{§Çº¦¸©w¸o¡A¥i³B²Ä6¯Å»@´Ú¤ÎºÊ¸T6Ó¤ë¡F
(iv)
on a second or subsequent
summary conviction to a fine of $1 million and to imprisonment for 1 year; and
¤@¸g´`²©öµ{§Ç²Ä¤G¦¸©Î¨ä«á¨C¦¸©w¸o¡A¥i³B»@´Ú100¸U¤¸¤ÎºÊ¸T1¦~¡F¥H¤Î
(v)
in any case where the
offence is of a continuing nature, the court or magistrate may impose a fine of
$ 10,000 for each day on which he is satisfied the offence continued.
¦b¥ô¦ó±¡ªp¤U¦p¸Ó¸o¦æÄݳsÄò©Ê½è¡Aªk°|©Îµô§P©x¥i´N¨ä«H¯Ç¸Ó¸o¦æ³sÄòªº¨C¤@¤Ñ¥t³B»@´Ú10,000¤¸¡C
8.
The Permit Holder may
appeal against any condition of this Permit under Section 17 of the Ordinance
within 30 days of receipt of this Permit.
³\¥iÃÒ«ù¦³¤H¥i¦b±µÀò¥»³\¥iÃÒ«á30¤Ñ¤º¡A®Ú¾Ú±ø¨Ò²Ä17±ø´N¥»³\¥iÃÒªº¥ô¦ó±ø¥ó´£¥X¤W¶D¡C
9. The Notes are for general reference only and that the
Permit Holder should refer to the Ordinance for details and seek independent
legal advice.
¤Wzµù¸Ñ¥u¨Ñ¤@¯ë°Ñ¦Ò¥Î¡A±ýª¾¦³Ãö¸Ô±¡¡A³\¥iÃÒ«ù¦³¤H¶·°Ñ¾\±ø¨Ò¤Î¼x¸ß¿W¥ßªk«ß·N¨£¡C
Environmental Permit No. EP-349/2009/L
Àô¹Ò³\¥iÃÒ½s¸¹ EP-349/2009/L
| Figure 1 |
[ Back to First Page ] / [ Back to Main
Index ]