Appendix 5.3 Proposed Powered Mechanical Equipment with
Mitigation Measures |
|
|
||||
|
|
|
|
|
|
|
Construction Stage |
|
|
|
|
|
|
|
|
|
|
|
|
|
Equipment |
Quantity |
TM reference |
% on-time |
Barrier Correction |
SWL per Piece dB(A) |
Sub-Total SWL dB(A) |
Generator Set |
2 |
R1 |
100 |
0 |
95 |
98 |
Excavator |
1 |
R2 |
80 |
0 |
105 |
104 |
150T Mobile Crane |
2 |
R2 |
70 |
0 |
106 |
107 |
Service Truck |
2 |
R2 |
60 |
0 |
109 |
110 |
Vibration Poker |
2 |
R2 |
70 |
0 |
100 |
101 |
Pneumatic Breaker |
1 |
CNP 025 |
80 |
0 |
111 |
110 |
Compressor |
1 |
CNP001 |
80 |
0 |
100 |
99 |
Concrete Mixer Truck |
2 |
CNP 044 |
90 |
0 |
109 |
112 |
Total SWL in dB(A) |
|
|
|
|
|
116.5 |
|
|
|
|
|
|
|
Operation Stage 1 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Equipment |
Quantity |
TM reference |
% on-time |
Barrier Correction |
SWL per Piece dB(A) |
Sub-Total SWL dB(A) |
Wheel Loader |
1 |
CNP 081 |
80 |
0 |
112 |
111 |
Concrete Recycle Machine |
1 |
CNP 045 |
100 |
0 |
96 |
96 |
Generator |
1 |
CNP 101 |
100 |
0 |
108 |
108 |
Concrete Wet Mixer |
1 |
CNP 045 |
90 |
0 |
96 |
96 |
Tipper Truck |
1 |
CNP 067 |
60 |
0 |
117 |
115 |
Cement Tanker |
1 |
CNP 141 |
60 |
0 |
112 |
110 |
barge |
1 |
CNP 061 |
80 |
0 |
104 |
103 |
Concrete Mixer Truck |
3 |
CNP 044 |
90 |
0 |
109 |
113 |
Batching Plant |
1 |
CNP 022 |
100 |
0 |
108 |
108 |
Compressor |
3 |
CNP001 |
80 |
0 |
100 |
104 |
Total SWL in dB(A) |
|
|
|
|
|
120 |
|
|
|
|
|
|
|
Operation Stage 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Equipment |
Quantity |
TM reference |
% on-time |
Barrier Correction |
SWL per Piece dB(A) |
Sub-Total SWL dB(A) |
Wheel Loader |
1 |
CNP 081 |
80 |
0 |
112 |
111 |
Concrete Recycle Machine |
1 |
CNP 045 |
100 |
0 |
96 |
96 |
Generator |
4 |
CNP 101 |
100 |
0 |
108 |
114 |
Concrete Wet Mixer |
3 |
CNP 047 |
80 |
0 |
109 |
113 |
Cement Blower |
3 |
CNP 045 |
80 |
0 |
96 |
100 |
Tipper Truck |
1 |
CNP 067 |
60 |
0 |
117 |
115 |
barge |
3 |
CNP 061 |
80 |
0 |
104 |
108 |
Concrete Mixer Truck |
8 |
CNP 044 |
90 |
0 |
109 |
118 |
Batching Plant |
1 |
CNP 022 |
100 |
0 |
108 |
108 |
Compressor |
6 |
CNP 003 |
80 |
0 |
104 |
111 |
Total SWL in dB(A) |
|
|
|
|
|
122 |
|
|
|
|
|
|
|
Note:
|
|
|
|
|
|
|
R1:
Environmental Permit Variation for Road Work for Cyber Port
Development - Construction Noise Impact Assessment Report (February 2000) |
||||||
R2:
Northern Access Road for Cyberport Development Environmental Permit Application
- Supplementary Environmental Assessment Report (July 2000) |
||||||
|
|
|
|
|
|
|
Phase 1 Construction of Stage 1 |
|
|
|
|
||
Phase 2 Consrruction of Stage 2 and
operation of Stage 1 |
|
|
|
|
||
Phase 3 Operation of Stage 2 |
|
|
|
|