Appendix 5.1                 Background Noise Survey

 

 

1.         Location

 

1.1       The noise survey for the existing background noise was carried out at the Area 44, Tuen Mun. The measurement locations are shown in the Figure 1.

 

2.         Date and Time

 

2.1       The noise survey was carried out on 22 Nov. 2000 between 03:28 to 04:43 hours.

 

3.         Personnel

 

3.1              Mr. Gary Yim (Scientific Officer)

Mr. Vincent Pow (Scientific Officer)

 

4.         Instrumentation

 

4.1       Type 1 sound level meter, SLM (Rion NA27) and Calibrator (Rion NC73) were used to perform the noise survey.

 

5.         Weather Conditions

 

5.1       The sky was clear and with light wind during the noise survey period.

 

6.         Survey Procedure

 

6.1       The SLM was placed at a height of 1.2m above ground surface. The SLM was positioned at 1 m away from building façade where applicable.

 

6.2       The SLM was calibrated immediately prior to and after noise measurements.

 

6.3              Noise measurement was conducted for three locations. The Leq(15min), L10 and L90 were recorded during the survey.

 

6.4       The background noise survey record sheet is attached.

 

7.         Noise Survey Result

 

7.1              The background noise levels recorded during the survey are shown below.

 

The background noise survey results:

 

Location

Time Period

Noise Level, dB(A)

Leq

L10

L90

BG1

0328 - 0343

62.3

61.6

48.6

BG2

0357 - 0412

57.2

58.8

47.9

BG3

0428 - 0443

56.8

57.0

45.9

 

Noise Measurement Data Sheet                      Sheet   1  of  1

 

Monitoring Location

Area 44, Tuen Mun

 

Weather

Light wind

Date of Monitoring

22 November 2000

Personnel

Gary Yim & Vincent Pow

Time (hh:mm)

0328 - 0443

Calibrated Level

Before

94.0 dB(A)

After

94.0 dB(A)

Sound Level Meter

(Model, S/N)

RION NA-27

S/N: 01070547

Calibrator

(Model, S/N)

RION NC-73

S/N: 10186489

Measurements Results

Location ID

Time Period

Noise Levels (dBA)

Remarks

Leq,dB(A)

L10, dB(A)

L90, dB(A)

BG1

0328 - 0343

62.3

61.6

48.6

 

BG2

0357 - 0412

57.2

58.8

47.9

 

BG3

0428 - 0443

56.8

57.0

45.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allied Environmental Consultants  Ltd

Acousticians   &   Environmental    Engineers

 

No. 10, 40/F., Jardine House, 1 Connaught Place, Central, Hong Kong.

Tel : (852) 2815 7028    Fax: (852) 2815 5399   e-mail: aecl@netvigator.com