Annex 1          Determination of Sound Power Levels of the Fixed Noise Sources

 

1.      The Sound Level Meter (SLM) was placed at a height of 1.2m above ground surface.  The SLM was positioned at a place with no sound reflecting objects in its vicinity.  The dominant noise emission is from the operation activities being assessed.

 

2.      The SLM was positioned at a distance of 2 m away from the noise sources.

 

3.      The SLM was calibrated immediately prior to and following each noise measurement.

 

4.      The noise equivalent levels (Leq) with 2 minutes measurement period were recorded and converted to the sound power level using the following equation:

 

Lw = Leq + 20log r + 8

where:

Lw is the sound power level of the source, dB(A)

Leq is the equivalent sound pressure level, dB referenced to 2 x 10-5Pa

r is the slant distance between noise source and the receiver (m)

 

5.      The measured noise level and the estimated sound power level of the fixed noise sources arising from the operational activities are tabulated below.

 

Operational  Activities

Location

Measured Noise Levels, Leq, dB(A)

Distance from source

r, m

Estimated Sound Power Level, dB(A)

Material Hoist

Sorting area, G/F

73

2

87

Icing Machine

WFM hall, G/F

82

2

96

Lorries parking

Car park, G/F

70

2

84

Sampans Idling

Berthing area

88

2

102

Fish vessels Idling

Berthing area

88

2

102

Unloading of fish containers from sea vessels

Sorting area, G/F

79

2

93

Auction and Marshalling

WFM hall, G/F

80

2

94

Weighting Operation

WFM hall, G/F

85

2

99

Loading of fish containers to lorries

Car park, G/F

70

2

84