Noise survey for Operation Activities of the WFM

 

1.         Location

 

1.1       The noise survey for operation activities of the WFM was carried out in the existing temporary Wholesale Fish Market at Sam Shing Estate.

 

2.         Date and Time

 

2.1       The noise survey was carried out on 25 August 2001 between 03:00 to 05:00.

 

3.         Personnel

 

3.1              Mr. James Wong (AEC)

Mr. Adi Lee (AEC)

Ms. Alice Tang (AEC)

 

4.         Instrumentation

 

4.1       Type 1 sound level meter; SLM (Rion NA27) and Calibrator (Rion NC73) were used to perform the noise survey.

 

5.         Weather Conditions and sea condition

 

5.1       The wind was calm and the sky was clear.

 

6.         Survey Procedure

 

6.1       The SLM was placed at a height of 1.2m above ground surface.  The SLM was positioned at a place with no sound reflecting objects in its vicinity.  The dormant noise emission is from the selected operation activities.

 

6.2       The SLM was positioned at a distance 2 m away the centre of the activities.

 

6.3       The SLM was calibrated immediately prior to and following each noise measurement.

 

6.4              The noise equivalent levels (Leq) with 2 minutes measurement period were recorded and converted to the sound power level using the following equation:

 

Leq = Lw - 20log r – 8

 

where:

Leq is the equivalent sound pressure level, dB reference to 2 x 10-5Pa

Lw is the sound power level of the source, dB(A)

r is the slant distance between noise source and the receiver (m)

 

6.5       The noise survey record sheets are attached.

 

7.         Noise Survey Result

 

7.1       The noise survey results are attached in the record sheet.

 


Monitoring Location

Exiting temporary Wholesale Fish Market (WFM)

 

Date of Monitoring

25-8-01

 

Time (hh:mm)

0300 – 0500

 

Weather Condition

Clear Sky

 

Wind Speed

Calm

 

Investigators

James Wong, Adi Lee & Alice Tang

 

Sound Level Meter

(Model, S/N)

Rion, NA27

 

Calibrator

(Model, S/N)

Rion, NC 73

 

Calibration

Before: 94.0 dB(A)

After: 94.0 dB(A)

 

Measurements Results

 

Operation Activities

Location

Number of Source

Noise Levels, Leq, dB(A)

Icing Machine

G/F

2

82

Unloading of fish containers from sea vessels

Pier, G/F

4

79

Auction and Marshalling

G/F

4

80

Weighting Operation

G/F

4

85

Loading of fish containers to lorries

Car Park, G/F

4

70