Noise survey for sampans and fish vessels idling

 

1.         Location

 

1.1       The noise survey for sampans and fish vessels idling was carried out in the existing temporary Wholesale Fish Market at Sam Shing Estate.

 

2.         Date and Time

 

2.1       The noise survey was carried out on 16 May 2001 between 03:00 to 05:00.

 

3.         Personnel

 

3.1              Dr. Mohamed Hasnain Isa (Senior Consultant)

Mr. Gary Yim (Scientific Officer)

 

4.         Instrumentation

 

4.1       Type 1 sound level meter, SLM (Rion NA27) and Calibrator (Rion NC73) were used to perform the noise survey.

 

5.         Weather Conditions and sea condition

 

5.1       The wind was calm and the sky was clear. The sea condition was calm during the noise survey period.

 

6.         Survey Procedure

 

6.1       The SLM was placed on the breakwater, at a height of 1.2m above ground surface and at a height of approximately 3m above the water surface.  The SLM was positioned at a place with no sound reflecting objects in its vicinity.

 

6.2       The distance from the side of the fishing vessels and sampans to the SLM was about 25m.

 

6.3       The SLM was calibrated immediately prior to and following each noise measurement.

 

6.4                   Four samples were collected during the noise survey period.  The equivalent noise levels (Leq) were recorded from the idling vessels.

 

6.5       The noise survey record sheets were attached.

 

7.         Noise Survey Result

 

7.1       The noise survey results are attached in the record sheet; highlight results used in the assessment.

 

Monitoring Location

Exiting temporary Wholesale Fish Market (WFM)

 

Date of Monitoring

16-5-01

 

Time (hh:mm)

0300 – 0500

 

Weather Condition

Clear Sky

 

Wind Speed

Calm

 

Sea Condition

Calm

 

Investigators

Gary Yim & Mohamed Hasnain Isa

 

Sound Level Meter

(Model, S/N)

Rion, NA27

 

Calibrator

(Model, S/N)

Rion, NC 73

 

Calibration

Before: 94.0 dB(A)

After: 94.0 dB(A)

 

Measurements Results

 

Measurement Point

Location of Measurement

Time Period

Noise Levels, dB(A)

Leq

Lmax

Lmin

Fish vessel – Idling

Distance 25m

At the parking area beside the WFM

30 sec

58.3

60.9

57.2

Fish vessel – Idling

Distance 25m

At the parking area beside the WFM

30 sec

58.3

60.7

57.2

Fish vessel – Idling

Distance 25m

At the parking area beside the WFM

4 min

58.2

62.9

56.2

Fish vessel – Idling

Distance 25m

Dam

5 min

65.8

69.7

62.8