Calculation of Noise Level Due to
Operation of Wind Turbine |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NSR Location: |
1 Tai Ling Tsuen |
|
|
|
Horizontal Distance= |
260 |
m |
|
Vertical Distance= |
60 |
m |
|
Slant Distance= |
267 |
|
|
Frequency,
Hz |
125 |
250 |
500 |
1000 |
2000 |
4000 |
|
|
|
SWL(1), dB(A) |
85.6 |
92.2 |
95.5 |
94.1 |
89.9 |
84.4 |
|
|
|
|
|
|
|
|
|
|
Distance |
267 |
267 |
267 |
267 |
267 |
267 |
|
|
|
Distance correction |
-57 |
-57 |
-57 |
-57 |
-57 |
-57 |
|
|
|
Screening correction |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
|
Atmospheric Absorption(2) |
-0.1 |
-0.3 |
-0.7 |
-1.3 |
-2.4 |
-6.1 |
|
|
|
|
|
|
|
|
Predicted Lp |
29 |
35 |
38 |
36 |
31 |
22 |
|
|
|
A-Weighting, dB |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
0.0 |
|
|
|
|
|
|
|
|
Lp, dB(A) |
29.0 |
35.4 |
38.2 |
36.2 |
31.0 |
21.8 |
|
|
|
A-Wt Sound Pr. Level = |
|
42.2 |
dB(A) |
|
-1.3 |
|
|
|
|
|
#REF! |
|
|
FACADE CORRECTION= |
3 |
dB(A) |
|
|
|
|
|
|
PREDICTED
FACADE NOISE LEVEL AT NSR = |
|
45 |
dB(A) |
|
|
|
|
|
Note: |
|
|
|
|
|
(1) Reference has been made on the Type Approval report of a typical
600 - 850kW class wind turbine with adjustment to |
|
|
represent the
worst case scenario of a maximum sound power level of 100dB(A). The sound power levels of the |
|
|
wind turbine are measured in
accordance with the Standard “The
Danish Ministry of Energy Order No. 304 of 14 May |
|
|
1991" and the guidelines from the
Danish Environmental Agency's Laboratory. The report
indicates that there are |
|
|
no audible tones in the noise. |
|
|
|
-2.4 |
(2) Basing on ISO 9613:Part 2 for Atmospheric Absorption at 20°C and
Relative Humidity 70%, with reference |
|
|
made on
the approved EIA for Construction of an
International Theme Park in Penny’s Bay of North Lantau and its |
|
|
Essential
Associated Infrastructures, February 2000, ERM |
|
|
|
#REF! |
|
|
|
|
|
|
793 |
3453 |
6650 |
4208 |
1251 |
150 |
|
|
16506 |
|
|
42.176 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|