Calculation of Noise Level Due to
Operation of Wind Turbine |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NSR Location: |
3 Tai
Ling Tsuen |
|
|
Horizontal Distance= |
357 |
m |
|
Vertical Distance= |
71 |
m |
|
Slant Distance= |
364 |
|
|
Frequency,
Hz |
125 |
250 |
500 |
1000 |
2000 |
4000 |
|
SWL(1), dB(A) |
85.6 |
92.2 |
95.5 |
94.1 |
89.9 |
84.4 |
|
|
|
|
Distance |
364 |
364 |
364 |
364 |
364 |
364 |
|
Distance correction |
-59 |
-59 |
-59 |
-59 |
-59 |
-59 |
|
Screening correction |
-5 |
-5 |
-5 |
-5 |
-5 |
-5 |
|
Atmospheric Absorption(2) |
-0.1 |
-0.4 |
-1.0 |
-1.8 |
-3.3 |
-8.3 |
|
|
|
|
|
|
Predicted Lp |
21 |
28 |
30 |
28 |
22 |
12 |
|
A-Weighting, dB |
|
|
|
|
|
|
|
|
|
|
Lp, dB(A) |
21.3 |
27.6 |
30.3 |
28.1 |
22.4 |
11.8 |
|
A-Wt Sound Pr. Level = |
|
34.1 |
dB(A) |
|
|
|
|
|
|
FACADE CORRECTION= |
3 |
dB(A) |
|
|
|
|
|
|
|
PREDICTED
FACADE NOISE LEVEL AT NSR = |
|
37 |
dB(A) |
|
|
|
|
|
Note: |
|
|
|
(1) Reference has been made on the Type Approval report of a typical
600 - 850kW class wind turbine with adjustment to |
|
represent the
worst case scenario of a maximum sound power level of 100dB(A). The sound power levels of the |
|
wind turbine are measured in
accordance with the Standard “The
Danish Ministry of Energy Order No. 304 of 14 May |
|
1991" and the guidelines from the
Danish Environmental Agency's Laboratory. The report
indicates that there are |
|
no audible tones in the noise. |
|
|
|
(2) Basing on ISO 9613:Part 2 for Atmospheric Absorption at 20°C and
Relative Humidity 70%, with reference |
|
made on
the approved EIA for Construction of an
International Theme Park in Penny’s Bay of North Lantau and its |
|
Essential
Associated Infrastructures, February 2000, ERM |
|
|
|
|
|
|
|
|
134 |
573 |
1061 |
639 |
174 |
15 |
|
|
2597 |
|
|
34.144 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|