Calculation of Noise Level Due to Operation of Wind Turbine                                                      
     
NSR Location: 3 Tai Ling Tsuen    
Horizontal Distance= 357 m  
Vertical Distance= 71 m  
Slant Distance= 364  
 
Frequency, Hz 125 250 500 1000 2000 4000  
SWL(1), dB(A) 85.6 92.2 95.5 94.1 89.9 84.4  
     
Distance  364 364 364 364 364 364  
Distance correction -59 -59 -59 -59 -59 -59  
Screening correction -5 -5 -5 -5 -5 -5  
Atmospheric Absorption(2) -0.1 -0.4 -1.0 -1.8 -3.3 -8.3      
     
Predicted Lp 21 28 30 28 22 12  
A-Weighting, dB              
     
Lp, dB(A) 21.3 27.6 30.3 28.1 22.4 11.8  
A-Wt Sound Pr. Level =   34.1 dB(A)  
     
    FACADE CORRECTION= 3 dB(A)    
         
PREDICTED FACADE NOISE LEVEL AT NSR =   37 dB(A)  
       
Note:      
(1) Reference has been made on the Type Approval report of a typical 600 - 850kW class wind turbine with adjustment to  
   represent the worst case scenario of a maximum sound power level of 100dB(A). The sound power levels of the  
   wind turbine are measured in accordance with the Standard “The Danish Ministry of Energy Order No. 304 of 14 May  
   1991" and the guidelines from the Danish Environmental Agency's Laboratory. The report indicates that there are  
   no audible tones in the noise.      
(2) Basing on ISO 9613:Part 2 for Atmospheric Absorption at 20°C and Relative Humidity 70%, with reference   
    made on the approved EIA for Construction of an International Theme Park in Penny’s Bay of North Lantau and its  
    Essential Associated Infrastructures, February 2000, ERM      
     
 
  134 573 1061 639 174 15  
  2597  
  34.144