Appendix 4.1          Baseline Noise Survey Data

 

(1)            Monitoring Location

 

Baseline noise monitoring was undertaken at three locations as shown in Figure 4.1.

 

(2)            Monitoring Parameters and Frequency

 

The qualified staff undertook noise measurement at each location on three days including weekday and holiday.  Noise monitoring was carried out using sound level meters with respect to Leq (30 min), Lmax, Lmin, L10 and L90.  The measurement period was as in the following table.

 

Table 1            Baseline Noise Monitoring

 

Time Period

Type

Duration / min

Daytime (07:00-19:00)

A

30

Evening time (19:00-23:00)

B

30

Night-time (23:00-07:00)

C

30

 

All noise measurements were conducted in accordance with the Technical Memorandum for Assessment on Noise from Places Other than Domestic Premises, Public Places or Construction Sites.

 

(3)            Monitoring Equipment

 

As referred to the Technical Memorandum issued under the Noise Control Ordinance, sound level meters in compliance with the International Electromechanical Commission Publications 651:1979 (Type 1) and 804:1985 (Type 1) specification were used for carrying out the noise monitoring.

 

(4)        Field Monitoring Methodology and QA/QC Procedure

 

The sound level meter was set on a tripod at a height of 1.2m above ground level.  The meter was positioned away from any nearby reflective surfaces.  The battery condition was checked to ensure good functioning of the meter.  Parameters such as frequency weighting, the time weighting and the measurement time would be set as follows:

 

-  frequency weighting:            A

-  time weighting:                     Fast

- time measurement:                30 minutes

 

Prior to and after each noise measurement, the meter was calibrated using the Calibrator for 94 dB at 1000 Hz.  If the difference in the calibration level before and after measurement was more than 1 dB(A), the measurement would be considered invalid and repeat of noise measurement would be required after re-calibration or repair of the equipment.

 

The wind speed was checked with the portable wind meter.  No noise monitoring was conducted in the presence of fog, rain, and wind with a steady speed exceeding 5m/s, or wind with gusts exceeding 10m/s.

 

Noise measurement was paused during periods of high intrusive noise if possible and observation was recorded when intrusive noise could be avoided.

 

(5)               Monitoring Results

 

 

Date

Time Period

Monitoring Station

Noise Parameter, dB(A)

Leq (30 min)

L10

L90

Lmax

Lmin

Remarks

1/2/04

(Sunday)

A

LWT2

62.4

65.5

42.5

83.5

35.5

Traffic noise

A

LWT3

50.5

52.0

46.5

72.2

44.2

Pui O pumping station

A

ALWT2

56.5

60.0

44.0

75.8

36.5

Traffic noise

B

LWT2

55.0

59.5

40.0

68.7

39.3

Traffic noise

B

LWT3

49.8

50.0

46.5

78.8

44.5

Dog barking, Pui O pumping station

B

ALWT2

52.5

55.5

41.0

73.2

37.1

Traffic noise

Dog barking

C

LWT2

55.5

575

38.5

68.7

37.7

Traffic noise

C

LWT3

49.5

50.0

47.0

66.7

45.2

Pui O pumping station

C

ALWT2

50.9

53.5

41.5

67.9

36.6

Dog barking

2/2/04

(Monday)

A

LWT2

67.4

72.1

60.0

77.4

55.0

Traffic noise

A

LWT3

52.3

55.3

47.7

69.4

45.6

Traffic noise, Dog barking, Pui O pumping station

A

ALWT2

64.1

67.3

55.2

87.6

44.7

Traffic noise

B

LWT2

64.4

68.6

46.4

78.4

43.6

Traffic noise

B

LWT3

51.1

54.1

47.0

62.3

46.3

Traffic noise, Dog barking, Pui O pumping station

B

ALWT2

61.5

65.2

48.2

76.1

42.4

Traffic noise

C

LWT2

61.2

65.1

47.1

77.2

41.8

Traffic noise, Dog barking

C

LWT3

48.7

50.8

45.7

58.7

43.7

Traffic noise, Pui O pumping station

C

ALWT2

59.7

62.5

48.0

85.2

41.7

Traffic noise