Appendix
4.3 |
|
|
|
|
|
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated Scenario
(Use of Quiet Plant and Movable Noise Barrier for all NSRs except SK4 and
SK6) |
|
|
|
Sai Kung River |
|
Site Clearence |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
|
|
Total |
106 |
|
|
|
Channel
Construction |
|
Excavation CH350-CH165 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
3 |
85 |
100% |
10 |
80 |
|
|
Total |
106 |
|
|
|
Channel
Construction |
|
Excavation CH165-CH000 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
3 |
85 |
100% |
10 |
80 |
|
|
Total |
106 |
|
|
|
Box Culvert and Bridge(3) |
|
|
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Power Rammer (petrol)(2) |
CNP 169 |
1 |
108 |
100% |
5 |
103 |
|
|
Total |
103 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
2 |
85 |
100% |
10 |
78 |
|
|
Total |
105 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
100 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Excavator / Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
|
|
Total |
104 |
|
|
|
|
Max SWL for Box Culvert and Bridge |
105 |
Backfilling
/ Channel lining CH420-CH000 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Excavator / Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
|
|
Total |
105 |
Note: |
|
|
|
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
Appendix
4.3 |
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated Scenario
(Use of Quiet Plant and Movable Noise Barrier for NSR PK1 and PK5) |
|
|
|
Pak Kong River |
|
Site Clearence |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
|
|
Total |
106 |
|
|
|
|
|
Channel
Construction |
|
Excavation
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
10 |
85 |
Drainage Pump |
CNP 283 |
3 |
85 |
100% |
10 |
80 |
|
|
Total |
106 |
|
|
|
|
|
Box Culvert (3) |
|
|
|
|
Sheetpiling
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Power Rammer (petrol)(2) |
CNP169 |
1 |
108 |
100% |
5 |
103 |
|
|
Total |
103 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
10 |
85 |
Drainage Pump |
CNP 283 |
2 |
85 |
100% |
10 |
78 |
|
|
Total |
106 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
|
|
Total |
106 |
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
106
|
|
|
|
|
|
|
Retaining
Wall |
|
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1) |
BS C6/40 |
3 |
98 |
70% |
10 |
91 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
Backfilling / Channel lining |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
|
|
Total |
107 |
|
|
|
Note: |
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
Appendix
4.3 |
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated Scenario
(Use of Quiet Plant and Movable Noise Barrier for all NSRs excpet HC1, HC4
and HC6) |
|
|
|
Ho Chung Channel |
|
Site Clearence |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
0 |
104 |
|
|
Total |
106 |
|
|
|
Channel
Construction |
|
Excavation |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
3 |
85 |
100% |
10 |
80 |
|
|
Total |
106 |
|
|
|
Box
Culvert and Bridge CH320(3) |
|
|
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
0 |
100 |
|
|
Total |
100 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
2 |
85 |
100% |
10 |
78 |
|
|
Total |
105 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
100 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Excavator / Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
|
|
Total |
104 |
|
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
105
|
|
|
|
|
Box Culvert and Bridge CH190(3) |
|
|
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
0 |
100 |
|
|
Total |
100 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
0 |
95 |
Drainage Pump(2) |
CNP 283 |
2 |
85 |
100% |
10 |
78 |
|
|
Total |
105 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
100 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Excavator / Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
|
|
Total |
104 |
|
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
105
|
Weir System |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
|
|
|
Retaining Wall CH650-CH330 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
Retaining Wall CH153-CH100 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
Floodwall |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
0 |
101 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
103 |
|
|
|
Backfilling / Channel lining |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
0 |
101 |
Excavator / Loader(1),(2) |
BS C3/97 |
1 |
105 |
80% |
5 |
99 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
0 |
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
|
|
Total |
105 |
|
|
|
Pilling
Work in Ho Chung CH20-CH189(4) |
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
0 |
100 |
|
|
Total |
100 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
100 |
|
|
|
|
|
|
|
|
|
Max SWL for Piling Work in Ho Chung |
100 |
Pilling
Work in Ho Chung CH350-CH450(4) |
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
0 |
100 |
|
|
Total |
100 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1)(2) |
C7/114 |
1 |
101 |
70% |
5 |
94 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
0 |
98 |
Vibratory Poker(1),(2) |
BS C6/40 |
2 |
98 |
70% |
10 |
89 |
Bar Bender / Cutter(2) |
CNP 021 |
1 |
90 |
100% |
5 |
85 |
|
|
Total |
100 |
|
|
|
|
|
|
|
|
|
Max SWL for Piling Work in Ho Chung |
100 |
|
|
|
|
Note: |
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
(4) For Piling Work in Ho Chung Area, piling and reinforcement
fixing/concret operation will not be carried out at the same time. Thus, the
maximum SWL of these activties will be used for calculation. |
|
Appendix
4.3 |
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated
Scenario-(Use of Quiet Plant and Temporary Noise Barrier for SK4 and SK6) |
|
|
|
Sai Kung River |
|
Site Clearence |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
|
|
Total |
107 |
|
|
|
Channel
Construction |
|
Excavation CH350-CH165 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
3 |
85 |
100% |
|
90 |
|
|
Total |
109 |
|
|
|
Channel
Construction |
|
Excavation CH165-CH000 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
3 |
85 |
100% |
|
90 |
|
|
Total |
109 |
|
|
|
Box Culvert and Bridge(3) |
|
|
|
|
Piling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Power Rammer (petrol) |
CNP 169 |
1 |
108 |
100% |
|
108 |
|
|
Total |
108 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
2 |
85 |
100% |
|
88 |
|
|
Total |
107 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
104 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
|
|
Total |
106 |
|
|
|
|
Max SWL for Box Culvert and Bridge |
108 |
Backfilling
/ Channel lining CH420-CH000 |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
|
|
Total |
108 |
Note: |
|
|
|
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
Appendix
4.3 |
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated
Scenario-(Use of Quiet Plant and Temporary Noise Barrier for PK2-4) |
|
|
|
Pak Kong River |
|
Site Clearence |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
|
|
Total |
107 |
|
|
|
|
|
Channel
Construction |
|
Excavation
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
3 |
85 |
100% |
|
90 |
|
|
Total |
109 |
|
|
|
|
|
Box Culvert (3) |
|
|
|
|
Sheetpiling
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Power Rammer, (petrol) |
CNP169 |
1 |
108 |
100% |
|
108 |
|
|
Total |
108 |
|
Earthworks |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
2 |
85 |
100% |
|
88 |
|
|
Total |
108 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
105 |
|
|
|
|
|
Backfilling |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
|
|
Total |
108 |
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
108 |
|
|
|
|
|
|
Retaining
Wall |
|
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
3 |
98 |
70% |
|
101 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
106 |
Backfilling / Channel lining |
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
|
|
Total |
109 |
|
|
|
Note: |
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
|
|
Appendix
4.3 |
|
|
Powered
Mechanical Equipment (PME) for Different Construction Tasks During Normal
Daytime Working Hours - |
Mitigated
Scenario-(Use of Quiet Plant and Temporary Noise Barrier for HC1, HC4 and
HC6) |
|
|
|
|
|
Ho Chung Channel |
|
|
Site Clearence |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
2 |
103 |
70% |
|
104 |
|
|
Total |
107 |
|
|
|
Channel
Construction |
|
|
Excavation |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
3 |
85 |
100% |
|
90 |
|
|
Total |
109 |
|
|
|
Box
Culvert and Bridge CH320(3) |
|
|
|
|
Piling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
|
100 |
|
|
Total |
100 |
|
|
Earthworks |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
2 |
85 |
100% |
|
88 |
|
|
Total |
107 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
104 |
|
|
|
|
|
Backfilling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
|
|
Total |
106 |
|
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
107
|
|
|
|
|
Box Culvert and Bridge CH190(3) |
|
|
|
|
Piling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
|
100 |
|
|
Total |
100 |
|
|
Earthworks |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Excavator(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Generator(1) |
CNP103 |
1 |
95 |
100% |
|
95 |
Drainage Pump |
CNP 283 |
2 |
85 |
100% |
|
88 |
|
|
Total |
107 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
104 |
|
|
|
|
|
Backfilling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
|
|
Total |
106 |
|
|
|
|
|
|
Max SWL for Box Culvert and Bridge |
107
|
Weir System |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
|
105 |
|
|
|
Retaining Wall CH650-CH330 |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
105 |
Retaining Wall CH153-CH100 |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
105 |
Floodwall |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
2 |
100 |
70% |
|
101 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
105 |
|
|
|
Backfilling / Channel lining |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Dump Truck(1) |
BS C9/39 |
1 |
103 |
70% |
|
101 |
Excavator / Loader(1) |
BS C3/97 |
1 |
105 |
80% |
|
104 |
Vibratory Roller(1) |
BS C8/25 |
1 |
96 |
100% |
|
96 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
|
|
Total |
108 |
|
|
|
Pilling
Work in Ho Chung CH20-CH189(4) |
|
|
Piling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
|
100 |
|
|
Total |
100 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
104 |
|
|
|
|
|
|
|
|
|
Max SWL for Piling Work in Ho Chung |
104 |
Pilling
Work in Ho Chung CH350-CH450(4) |
|
|
Piling |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Piling, large diameter bored,
reverse circulation drill |
CNP166 |
1 |
100 |
100% |
|
100 |
|
|
Total |
100 |
|
|
|
Reinforcement
Fixing / Concrete operations |
|
|
Powered Mechanical Equipment |
TM Ref./ |
No. of Items |
SWL/Item |
On-time |
Barrier |
Total SWL |
(PME) |
other Ref. |
|
dB(A) |
% |
dB |
dB(A) |
Crane(1) |
C7/114 |
1 |
101 |
70% |
|
99 |
Concrete Lorry Mixer(1) |
BS C6/23 |
1 |
100 |
70% |
|
98 |
Vibratory Poker(1) |
BS C6/40 |
2 |
98 |
70% |
|
99 |
Bar Bender / Cutter |
CNP 021 |
1 |
90 |
100% |
|
90 |
|
|
Total |
104 |
|
|
|
|
|
|
|
|
|
Max SWL for Piling Work in Ho Chung |
104 |
|
|
|
|
Note: |
|
(1) Use of Quieter Plant |
|
(2) Use of Movable Barrier |
|
(3) For Box Culvert and Bridge, piling, earthworks,
reinforcement fixing/concret operation and backfilling will not be carried
out at the same time. Thus, the maximum SWL of these activties will be used
for calculation. |
(4) For Piling Work in Ho Chung Area, piling and reinforcement
fixing/concret operation will not be carried out at the same time. Thus, the
maximum SWL of these activties will be used for calculation. |
|
|
|
|
|
|
|