Table C.1        Worst-case SO2 Concentrations before and after the Retrofit

ASR

Source B

Before

Retrofit(a)

μg m-3

Source B

After

Retrofit(b)

μg m-3

Other Sources(c)

μg m-3

Back-ground(a)

Total

Before Retrofit(a)

μg m-3

Total

After

Retrofit(d)

μg m-3

Retrofit Impact

μg m-3

Retrofit Impact

%

1

0

0

113

23

136

136

0

0

2

1

0

91

23

115

114

-1

-1

3

0

0

45

23

68

68

0

0

4

9

1

164

23

196

188

-8

-4

5

0

0

133

23

156

156

0

0

6

9

1

146

23

178

170

-8

-4

7

65

10

249

23

337

282

-55

-16

8

5

1

133

23

161

157

-4

-3

9

22

3

149

23

194

175

-19

-10

10

93

14

266

23

382

303

-79

-21

11

8

1

65

23

96

89

-7

-7

12

4

1

80

23

107

104

-3

-3

13

1

0

27

23

51

50

-1

-2

14

0

0

40

23

63

63

0

0

15

27

4

55

23

105

82

-23

-22

16

16

2

70

23

109

95

-14

-13

17

34

5

94

23

151

122

-29

-19

18

39

6

76

23

138

105

-33

-24

19

4

1

40

23

67

64

-3

-5

20

1

0

66

23

90

89

-1

-1

21

16

2

121

23

160

146

-14

-9

22

103

15

35

23

161

73

-88

-55

23

165

24

69

23

257

116

-141

-55

24

308

45

157

23

488

225

-263

-54

25

176

26

83

23

282

132

-150

-53

26

128

19

182

23

333

224

-109

-33

27

14

2

195

23

232

220

-12

-5

28

116

17

261

23

400

301

-99

-25

29

262

39

412

23

697

474

-223

-32

30

178

26

193

23

394

242

-152

-39

31

83

12

79

33

195

124

-71

-36

32

92

14

79

33

204

126

-78

-38

33

20

3

75

23

118

101

-17

-14

34

34

5

100

23

157

128

-29

-18

35

110

16

183

23

316

222

-94

-30

36

135

20

217

23

375

260

-115

-31

37

46

7

117

23

186

147

-39

-21

38

66

10

154

23

243

187

-56

-23

39

68

10

109

23

200

142

-58

-29

40

124

18

153

33

310

204

-106

-34

41

47

7

79

33

159

119

-40

-25

42

119

17

211

23

353

251

-102

-29

43

87

13

153

23

263

189

-74

-28

44

45

7

93

23

161

123

-38

-24

45

98

14

168

23

289

205

-84

-29

46

124

18

203

23

350

244

-106

-30

47

69

10

115

33

217

158

-59

-27

48

58

9

101

33

192

143

-49

-26

49

25

4

89

23

137

116

-21

-16

50

67

10

145

23

235

178

-57

-24

51

110

16

172

23

305

211

-94

-31

52

44

6

120

23

187

149

-38

-20

53

69

10

160

23

252

193

-59

-23

54

245

36

349

23

617

408

-209

-34

55

67

10

101

33

201

144

-57

-28

56

86

13

130

33

249

176

-73

-29

57

73

11

151

23

247

185

-62

-25

58

89

13

157

23

269

193

-76

-28

59

99

15

166

23

288

204

-84

-29

60

73

11

190

23

286

224

-62

-22

61

130

19

225

23

378

267

-111

-29

62

85

12

175

23

283

210

-73

-26

63

59

9

150

23

232

182

-50

-22

64

127

19

260

23

410

302

-108

-26

65

107

16

237

23

367

276

-91

-25

66

149

22

245

23

417

290

-127

-30

67

118

17

203

23

344

243

-101

-29

68

40

6

128

23

191

157

-34

-18

69

178

26

282

23

483

331

-152

-31

Notes:

(a)     From Table 5-1c of Project Profile for Lamma Power Station Conversion of Two Existing Gas Turbines into a Combined Cycle Unit, 2000

(b)     Equal to Source B contribution before the retrofit reduced by a factor of 0.147

(c)      Derived from Table 5-1c of Project Profile for Lamma Power Station Conversion of Two Existing Gas Turbines into a Combined Cycle Unit, 2000

(d)     Sum of Source B after the retrofit, other sources and the background

 


Table C.2        Worst-case Cumulative NO2 Concentrations after the Retrofit

ASR

Source B(a)

μg m-3

Other Sources(b)

μg m-3

Distance

Correction(c)

Background(a)

μg m-3

Total(d)

μg m-3

1

0

29

0.52

49

64

2

0

23

0.81

49

68

3

0

13

0.38

49

54

4

1

43

0.71

49

80

5

0

35

0.96

49

83

6

1

37

0.93

49

84

7

10

49

0.96

49

106

8

1

35

0.72

49

75

9

3

36

0.76

49

79

10

14

57

0.72

49

100

11

1

20

0.42

49

58

12

1

22

0.69

49

65

13

0

5

0.40

49

51

14

0

8

0.71

49

55

15

4

12

1.00

49

65

16

3

14

0.93

49

65

17

5

20

0.91

49

72

18

9

12

1.44

49

79

19

1

9

0.50

49

54

20

0

16

0.82

49

62

21

2

20

1.00

49

71

22

16

10

0.69

49

67

23

26

23

0.92

49

94

24

48

34

1.23

49

150

25

27

14

0.83

49

83

26

20

29

1.09

49

102

27

2

47

0.61

49

79

28

16

58

1.25

49

141

29

41

72

1.90

49

264

30

28

35

1.68

49

154

31

13

16

1.92

80

135

32

14

15

1.93

80

136

33

3

20

1.69

49

88

34

5

24

1.76

49

100

35

17

34

1.54

49

128

36

21

40

1.52

49

142

37

7

27

1.77

49

109

38

10

33

1.64

49

119

39

12

17

1.61

49

95

40

19

22

1.88

80

158

41

7

17

1.84

80

125

42

18

39

1.47

49

133

43

13

28

1.49

49

110

44

7

27

1.55

49

102

45

15

28

1.55

49

116

46

19

36

1.75

49

146

47

11

21

1.93

80

142

48

9

19

1.92

80

134

49

4

24

1.47

49

90

50

10

28

1.50

49

106

51

17

30

1.84

49

135

52

7

26

1.46

49

97

53

11

34

1.41

49

113

54

38

60

1.81

49

226

55

10

19

2.00

80

137

56

13

22

2.00

80

150

57

11

34

1.40

49

112

58

14

32

1.36

49

111

59

15

33

1.70

49

130

60

11

42

1.39

49

123

61

20

43

1.37

49

135

62

13

36

1.60

49

127

63

9

33

1.53

49

114

64

20

48

1.52

49

153

65

17

46

1.52

49

144

66

23

42

1.79

49

165

67

18

35

1.80

49

145

68

6

30

1.68

49

109

69

28

48

1.85

49

189

Notes:

(a)     From Table 5-1d of Project Profile for Lamma Power Station Conversion of Two Existing Gas Turbines into a Combined Cycle Unit, 2000

(b)     Derived from Table 5-1d of Project Profile for Lamma Power Station Conversion of Two Existing Gas Turbines into a Combined Cycle Unit, 2000

(c)      A correction factor based on the Janssen formula[1] that links the NO to NO2 conversion rate to the prevailing meteorological conditions, distance to the receptor and the background ozone concentrations

(d)     Sum of Source B and other sources multiplied by the distance correction and the background

 

 



 (1) [1] Janssen L.H.J.M. et al. A Classification of NO Oxidation Rates in Power Plant Plumes Based on Atmospheric Conditions. Atmospheric Environment, 22, 43-53, 1988