Table 3.10        Predicted Fixed Plant Noise Levels

NSRs

Predicted Noise Levels, dB(A)

Noise Criteria, dB(A)

Scenario I

(Not During Lagoon Night Show)

Scenario II

(During Lagoon Night Show) (1)

PTS1

53

51

60

SW2

51

49

60

HA

54

52

60

CV2

55

53

60

XC

53

51

60

IV1

54

53

60

OR

53

51

55

HY

53

51

55

MV

54

53

56

BC1*

53

53

62

Note:      

(1) During the lagoon night show, the PA clusters serving the show venue at Aqua City would not be turned on simultaneously with the loudspeakers used for the show.  It was assumed in the calculation that there would be 30 clusters of PA system serving the future Aqua City during the Lagoon Night Show,