Annex B-4 - Construction Noise Assessment                                                                                                        
                                                                                                                   
NSR: Village House at Sha Po Kong                                                                                                            
                      Correction Factor                                                                                      
Distance from NSR to Sources  1100 m to the nearest site boundary   Distance Attenuation -69 dB(A)   Barrier attenuation   -10 dB(A) for land based works(1) &  0 dB(A) for dredgeing work                                                  
Distance from NSR to Dredging Area  1100 m to the nearest site boundary   Distance Attenuation -69     Facade     3 dB(A)                                                                    
                                                                                                                   
                                                                                                                   
      2006             2007                       2008                       2009                       2010                      
      J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J J A S O N D
Construction Item                                                                                                                
Demolition of Oil Tank   0 0 0 0 0 0 0 124 124 124 124 124 124 124 124 124 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 124.2039591 124.2039591 124.2039591 124.2039591 124.2039591 124.2039591 124.2039591
    Total SWL 0 0 0 0 0 0 0 124 124 124 124 124 124 124 124 124 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 48 48 48 48 48 48 48 48 48 48 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
Site formation   0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 123 123 123 123 123 0 0 0 0 0 0 123 123 123 123 123 123 123 123 123 123 123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 124 124 124 124 124 124 124
    Total SWL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 123 123 123 123 123 0 0 0 0 0 0 123 123 123 123 123 123 123 123 123 123 123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 48 48 48 48 48 0 0 0 0 0 0 48 48 48 48 48 48 48 48 48 48 48 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
Annex B-4 - Construction Noise Assessment           0 0 113 113 113 113 0 0 0 0 0 0 113 113 113 113 113 113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 117 117 117 117 117 117 117
                      0 0 113 113 113 113 0 0 0 0 0 0 113 113 113 113 113 113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
NSR: Village House at Sha Po Kong               0 0 37 37 37 37 0 0 0 0 0 0 37 37 37 37 37 37 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
M&E Installation   0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 0
    Total SWL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 0
                                                                                                                   
Dredging Work   0 0 0 0 0 0 0 0 0 112 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF!
    Total SWL 0 0 0 0 0 0 0 0 0 112 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 46 46 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! 0 0 0 0 0
                                                                                                                   
OVERALL NOISE LEVEL AT NSR (dB(A)) 0 0 0 0 0 0 0 48 48 50 51 49 49 49 48 51 51 48 48 48 45 45 45 45 45 45 49 49 49 49 49 49 49 49 49 49 49 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! max 51 max 51
                                                                                                                    min 44
Note:                                                                                                                  
(1) With the construction activities will  be screened by the existing building structures at Castle Peak Power Station and topography, a negative correction factor of 10dB(A) has been applied in the assessment.                                                 
(1) Atmospheric attenuation coefficient is applied in accordance with ISO 9613:Part 2 in considering that construction noise dominated at frequency of 500 Hz and average atmospheric condition in Hong Kong ((i.e. 23oC and RH 79%) is made reference to the "                                                                                                                  
     by Hong Kong Observatory).                                                                                                                   
                                                                                                                   
NSR: Planned Holiday Camp                                                                                                              
                      Correction Factor                                                                                      
Distance from NSR to Sources  1200 m to the nearest site boundary   Distance Attenuation -70 dB(A)   Barrier attenuation   -10 dB(A) for land based works(1) &  -10 dB(A) for dredgeing work(1)                                                
Distance from NSR to Dredging Area  2000 m to the nearest site boundary   Distance Attenuation -74     Facade     3 dB(A)                                                                    
                                                                                                                   
                                                                                                                   
      2006             2007                       2008                       2009                       2010                      
      J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J J A S O N D
Construction Item                                                                                                                
Demolition of Oil Tank   0 0 0 0 0 0 0 124 124 124 124 124 124 124 124 124 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
    Total SWL 0 0 0 0 0 0 0 124 124 124 124 124 124 124 124 124 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 48 48 48 48 48 48 48 48 48 48 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
Site formation   0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 123 123 123 123 123 0 0 0 0 0 0 123 123 123 123 123 123 123 123 123 123 123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
    Total SWL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 123 123 123 123 123 0 0 0 0 0 0 123 123 123 123 123 123 123 123 123 123 123 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 47 47 47 47 47 0 0 0 0 0 0 47 47 47 47 47 47 47 47 47 47 47 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
Annex B-4 - Construction Noise Assessment 0 0 0 0 0 0 0 0 0 0 113 113 113 113 0 0 0 0 0 0 113 113 113 113 113 113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
    Total SWL 0 0 0 0 0 0 0 0 0 0 113 113 113 113 0 0 0 0 0 0 113 113 113 113 113 113 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 0 36 36 36 36 0 0 0 0 0 0 36 36 36 36 36 36 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
M&E Installation   0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 0
    Total SWL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 120 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
Dredging Work   0 0 0 0 0 0 0 0 0 112 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
    Total SWL 0 0 0 0 0 0 0 0 0 112 112 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Noise Level at NSR (dB(A)) 0 0 0 0 0 0 0 0 0 31 31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
                                                                                                                   
OVERALL NOISE LEVEL AT NSR (dB(A)) 0 0 0 0 0 0 0 48 48 48 48 48 48 48 48 50 50 47 47 47 44 44 44 44 44 44 48 48 48 48 48 48 48 48 48 48 48 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 0 #REF! #REF! #REF! #REF! #REF! #REF! #REF! max 50 max 50
                                                                                                                    min 43
Note:                                                                                                                  
(1) Atmospheric attenuation coefficient is applied in accordance with ISO 9613:Part 2 in considering that construction noise dominated at frequency of 500 Hz and average atmospheric condition in Hong Kong ((i.e. 23oC and RH 79%) is made reference to the "                                                                                                                  
     by Hong Kong Observatory).                                                                                                                   
(1) With the construction activities will  be screened by the existing building structures at Castle Peak Power Station and topography, a negative correction factor of 10dB(A) has been applied in the assessment.