Appendix 4.2 Tentative Construction Programme (Dechlorination Plant) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2008 |
2009 |
|||||||||||||||||
Construction Tasks |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Oct |
Nov |
Dec |
Jan |
Feb |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Site formation & site establishment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Excavation and backfilling |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Erection of formwork, reinforcement fixing & concreting |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fabrication of steelwork |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Installation of E&M equipment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Testing and commissioning |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Construction Noise Impact Assessment |
|
|
||||||
|
|
|
|
|
|
|
|
|
Powered Mechanical Equipment (PME) for Different Construction Tasks during |
||||||||
Normal Daytime Working Hours (Unmitigated Scenario) |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
Proposed Dechlorination Plant |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
Site formation & site establishment |
|
|
|
|
|
|||
Powered Mechanical Equipment |
|
TM Ref./ |
|
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Breaker, excavator mounted |
- |
- |
CNP028 |
1 |
122 |
100% |
0 |
122 |
Excavator |
- |
- |
CNP081 |
1 |
112 |
100% |
0 |
112 |
Dump Truck |
- |
- |
CNP067 |
1 |
117 |
100% |
0 |
117 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
Generator |
- |
- |
CNP102 |
1 |
100 |
100% |
0 |
100 |
|
|
|
|
|
|
|
Total |
124 |
|
|
|
|
|
|
|
|
|
Excavation and backfilling |
|
|
|
|
|
|
|
|
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Dump Truck |
- |
- |
CNP067 |
1 |
117 |
100% |
0 |
117 |
Excavator |
- |
- |
CNP081 |
1 |
112 |
100% |
0 |
112 |
Generator |
- |
- |
CNP102 |
1 |
100 |
100% |
0 |
100 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
Breaker, excavator mounted |
- |
- |
CNP028 |
1 |
122 |
100% |
0 |
122 |
|
|
|
|
|
|
|
Total |
124 |
|
|
|
|
|
|
|
|
|
Erection of formwork, reinforcement fixing & concreting |
|
|
|
|
||||
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Mobile Crane |
- |
- |
CNP048 |
1 |
112 |
100% |
0 |
112 |
Concrete Lorry Mixer |
- |
- |
CNP044 |
1 |
109 |
100% |
0 |
109 |
Bar Bender and cutter |
- |
- |
CNP021 |
1 |
90 |
100% |
0 |
90 |
Concete Pump |
- |
- |
CNP047 |
1 |
109 |
100% |
0 |
109 |
Poker |
- |
- |
CNP170 |
3 |
113 |
100% |
0 |
118 |
Chipper, hand held |
- |
- |
CNP043 |
1 |
112 |
100% |
0 |
112 |
Saw, circular wood |
- |
- |
CNP201 |
1 |
108 |
100% |
0 |
108 |
Generator |
- |
- |
CNP102 |
1 |
100 |
100% |
0 |
100 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
|
|
|
|
|
|
|
Total |
121 |
|
|
|
|
|
|
|
|
|
Fabrication of steelwork |
|
|
|
|
|
|
|
|
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Backhoe |
- |
- |
CNP081 |
1 |
112 |
100% |
0 |
112 |
Mobile Crane |
- |
- |
CNP048 |
1 |
112 |
100% |
0 |
112 |
Lorry |
- |
- |
CNP141 |
1 |
112 |
100% |
0 |
112 |
Generator |
- |
- |
CNP102 |
1 |
100 |
100% |
0 |
100 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
|
|
|
|
|
|
|
Total |
117 |
Construction Noise Impact Assessment |
|
|
||||||
|
|
|
|
|
|
|
|
|
Powered Mechanical Equipment (PME) for Different Construction Tasks during Normal |
||||||||
Daytime Working Hours (Mitigated Scenario - Use of Quiet Plant) |
|
|
||||||
|
|
|
|
|
|
|
|
|
Proposed Dechlorination Plant |
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
Site formation & site establishment |
|
|
|
|
|
|||
Powered Mechanical Equipment |
|
TM Ref./ |
|
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Breaker, excavator mounted |
[1] |
- |
C2/4 |
1 |
119 |
100% |
0 |
119 |
Excavator |
[1] |
- |
C3/97 |
1 |
105 |
100% |
0 |
105 |
Dump Truck |
[1] |
- |
C9/20 |
1 |
103 |
100% |
0 |
103 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
Generator |
[1] |
- |
CNP 103 |
1 |
95 |
100% |
0 |
95 |
|
|
|
|
|
|
|
Total |
119 |
|
|
|
|
|
|
|
|
|
Excavation and backfilling |
|
|
|
|
|
|
|
|
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Dump Truck |
[1] |
- |
C9/20 |
1 |
103 |
100% |
0 |
103 |
Excavator |
[1] |
- |
C3/97 |
1 |
105 |
100% |
0 |
105 |
Generator |
[1] |
- |
CNP 103 |
1 |
95 |
100% |
0 |
95 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
Breaker, excavator mounted |
[1] |
- |
C2/4 |
1 |
119 |
100% |
0 |
119 |
|
|
|
|
|
|
|
Total |
119 |
|
|
|
|
|
|
|
|
|
Erection of formwork, reinforcement fixing & concreting |
|
|
|
|
||||
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Mobile Crane |
[1] |
- |
C7/114 |
1 |
101 |
100% |
0 |
101 |
Concrete Lorry Mixer |
[1] |
- |
C6/23 |
1 |
100 |
100% |
0 |
100 |
Bar Bender and cutter |
- |
- |
CNP021 |
1 |
90 |
100% |
0 |
90 |
Concete Pump |
[1] |
- |
C6/36 |
1 |
106 |
100% |
0 |
106 |
Poker |
[1] |
- |
C6/32 |
3 |
100 |
100% |
0 |
105 |
Chipper, hand held |
- |
- |
CNP043 |
1 |
112 |
100% |
0 |
112 |
Saw, circular wood |
- |
- |
CNP201 |
1 |
108 |
100% |
0 |
108 |
Generator |
[1] |
- |
CNP 103 |
1 |
95 |
100% |
0 |
95 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
|
|
|
|
|
|
|
Total |
115 |
|
|
|
|
|
|
|
|
|
Fabrication of steelwork |
|
|
|
|
|
|
|
|
Powered Mechanical Equipment |
|
TM Ref./ |
No. Items |
SWL/Item |
On-time |
Noise Barrier |
Total SWL |
|
(PME) |
|
|
other Ref. |
|
dB(A) |
% |
Reduction |
dB(A) |
Backhoe |
[1] |
- |
C8/33 |
1 |
102 |
100% |
0 |
102 |
Mobile Crane |
[1] |
- |
C7/114 |
1 |
101 |
100% |
0 |
101 |
Lorry |
[1] |
- |
C3/59 |
1 |
105 |
100% |
0 |
105 |
Generator |
[1] |
- |
CNP 103 |
1 |
95 |
100% |
0 |
95 |
Air Compressor |
- |
- |
CNP002 |
1 |
102 |
100% |
0 |
102 |
|
|
|
|
|
|
|
Total |
109 |
Note: (1) Use of Quiet PME |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Appendix 4.2 Construction Noise Impact Assessment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Calculation of Construction Noise Levels at Representative NSR - Unmitigated Scenario |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NSR: N1 |
|
|
|
2008 |
2009 |
|||||||||||||||||
|
SWL |
Distance |
SPL |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Oct |
Nov |
Dec |
Jan |
Feb |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Site formation & site establishment |
124 |
120 |
77 |
|
|
|
|
|
|
77 |
77 |
|
|
|
|
|
|
|
|
|
|
|
Excavation and backfilling |
124 |
120 |
77 |
|
|
|
|
|
|
|
|
77 |
|
|
|
|
|
|
|
|
|
|
Erection of formwork, reinforcement fixing & concreting |
121 |
120 |
74 |
|
|
|
|
|
|
|
|
|
74 |
74 |
74 |
|
|
|
|
|
|
|
Fabrication of steelwork |
117 |
120 |
70 |
|
|
|
|
|
|
|
|
|
|
|
70 |
70 |
70 |
70 |
70 |
|
|
|
Installation of E&M equipment # |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
- |
|
|
Testing and commissioning # |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
- |
- |
|
|
|
Total SPL, dB(A) |
|
|
|
|
|
|
77 |
77 |
77 |
74 |
74 |
76 |
70 |
70 |
70 |
70 |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
# As advised by DSD, no PME would be required for installation of E&M equipment and testing & commissiong |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Appendix 4.2 Construction Noise Impact Assessment |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Calculation of Construction Noise Levels at Representative NSR - Mitigated Scenario |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NSR: N1 |
|
|
|
2008 |
2009 |
|||||||||||||||||
|
SWL |
Distance |
SPL |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Oct |
Nov |
Dec |
Jan |
Feb |
Mar |
Apr |
May |
Jun |
Jul |
Aug |
Sep |
Site formation & site establishment |
119 |
120 |
73 |
|
|
|
|
|
|
73 |
73 |
|
|
|
|
|
|
|
|
|
|
|
Excavation and backfilling |
119 |
120 |
73 |
|
|
|
|
|
|
|
|
73 |
|
|
|
|
|
|
|
|
|
|
Erection of formwork, reinforcement fixing & concreting |
115 |
120 |
69 |
|
|
|
|
|
|
|
|
|
69 |
69 |
69 |
|
|
|
|
|
|
|
Fabrication of steelwork |
109 |
120 |
62 |
|
|
|
|
|
|
|
|
|
|
|
62 |
62 |
62 |
62 |
62 |
|
|
|
Installation of E&M equipment # |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
- |
|
|
Testing and commissioning # |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
- |
- |
- |
|
|
|
Total SPL, dB(A) |
|
|
|
|
|
|
73 |
73 |
73 |
69 |
69 |
70 |
62 |
62 |
62 |
62 |
- |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
# As advised by DSD, no PME would be required for installation of E&M equipment and testing & commissiong |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|