Appendix 4.3      Tentative Construction Programme (Chlorination Plant & Pipe Trough at SCISTW)

 

 

 

 

 

2008

2009

 

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fabrication of steelwork

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation of E&M equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Testing and commissioning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Appendix 4.3     Tentative Construction Programme (Day Tank at SCISTW)

 

 

 

 

 

 

 

 

 

 

 

2008

2009

 

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piling 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installation of E&M equipment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Testing and commissioning

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Construction Noise Impact Assessment

Powered Mechanical Equipment (PME) for Different Construction Tasks during 

 

 

Normal Daytime Working Hours (Unmitigated Scenario)

 

 

 

 

 

 

 

 

 

 

 

 

 

Proposed Chlorination Plant and Day Tank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Site formation & site establishment

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

 

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Breaker, excavator mounted

-

-

CNP028

1

122

100%

0

122

Excavator

-

-

CNP081

1

112

100%

0

112

Dump Truck

-

-

CNP067

1

117

100%

0

117

Air Compressor

-

-

CNP002

1

102

100%

0

102

Generator

-

-

CNP102

1

100

100%

0

100

 

 

 

 

 

 

 

Total

124

 

 

 

 

 

 

 

 

 

Pilling Work (For Day Tank Only)

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Piling, large diameter bored

-

-

CNP164

1

115

100%

0

115

Mobile Crane

-

-

CNP048

1

112

100%

0

112

Water pump

-

-

CNP281

1

88

100%

0

88

Air Compressor

-

-

CNP002

1

102

100%

0

102

Concrete Pump

-

-

CNP047

1

109

100%

0

109

Bar Bender and cutter

-

-

CNP021

1

90

100%

0

90

Generator

-

-

CNP102

1

100

100%

0

100

 

 

 

 

 

 

 

Total

118

 

 

 

 

 

 

 

 

 

Excavation and backfilling

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Dump Truck

-

-

CNP067

1

117

100%

0

117

Excavator

-

-

CNP081

1

112

100%

0

112

Generator

-

-

CNP102

1

100

100%

0

100

Air Compressor

-

-

CNP002

1

102

100%

0

102

Breaker, excavator mounted

-

-

CNP028

1

122

100%

0

122

 

 

 

 

 

 

 

Total

124

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Mobile Crane

-

-

CNP048

1

112

100%

0

112

Concrete Lorry Mixer

-

-

CNP044

1

109

100%

0

109

Bar Bender and cutter

-

-

CNP021

1

90

100%

0

90

Concete Pump

-

-

CNP047

1

109

100%

0

109

Poker

-

-

CNP170

3

113

100%

0

118

Chipper, hand held

-

-

CNP043

1

112

100%

0

112

Saw, circular wood

-

-

CNP201

1

108

100%

0

108

Generator

-

-

CNP102

1

100

100%

0

100

Air Compressor

-

-

CNP002

1

102

100%

0

102

 

 

 

 

 

 

 

Total

121

 

 

 

 

 

 

 

 

 

Fabrication of steelwork (For Chlorination Plant Only)

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Backhoe

-

-

CNP081

1

112

100%

0

112

Mobile Crane

-

-

CNP048

1

112

100%

0

112

Lorry

-

-

CNP141

1

112

100%

0

112

Generator

-

-

CNP102

1

100

100%

0

100

Air Compressor

-

-

CNP002

1

102

100%

0

102

 

 

 

 

 

 

 

Total

117

 

 

 

 

 

 

 

 

 

Note: Except for piling work and fabrication of steelwork, a duplicate set of PME is assumed for construction of chlorination plant and day tank.

 

 

Powered Mechanical Equipment (PME) for Different Construction Tasks during Normal

 

 

Daytime Working Hours (Mitigated Scenario - Use of Quiet Plant)

 

 

 

 

 

 

 

 

 

 

 

 

 

Proposed Chlorination Plant and Day Tank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Site formation & site establishment

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

 

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Breaker, excavator mounted

[1]

-

C2/4

1

119

100%

0

119

Excavator

[1]

-

C3/97

1

105

100%

0

105

Dump Truck

[1]

-

C9/20

1

103

100%

0

103

Air Compressor

-

-

CNP002

1

102

100%

0

102

Generator

[1]

-

CNP 103

1

95

100%

0

95

 

 

 

 

 

 

 

Total

119

 

 

 

 

 

 

 

 

 

Pilling Work (For Day Tank Only)

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Piling, large diameter bored

-

-

CNP164

1

115

100%

0

115

Mobile Crane

[1]

-

C7/114

1

101

100%

0

101

Water pump

-

-

CNP281

1

88

100%

0

88

Air Compressor

-

-

CNP002

1

102

100%

0

102

Concete Pump

[1]

-

C6/36

1

106

100%

0

106

Bar Bender and cutter

-

-

CNP021

1

90

100%

0

90

Generator

[1]

-

CNP 103

1

95

100%

0

95

 

 

 

 

 

 

 

Total

116

 

 

 

 

 

 

 

 

 

Excavation and backfilling

 

 

 

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Dump Truck

[1]

-

C9/20

1

103

100%

0

103

Excavator

[1]

-

C3/97

1

105

100%

0

105

Generator

[1]

-

CNP 103

1

95

100%

0

95

Air Compressor

-

-

CNP002

1

102

100%

0

102

Breaker, excavator mounted

[1]

-

C2/4

1

119

100%

0

119

 

 

 

 

 

 

 

Total

119

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Mobile Crane

[1]

-

C7/114

1

101

100%

0

101

Concrete Lorry Mixer

[1]

-

C6/23

1

100

100%

0

100

Bar Bender and cutter

-

-

CNP021

1

90

100%

0

90

Concete Pump

[1]

-

C6/36

1

106

100%

0

106

Poker

[1]

-

C6/32

3

100

100%

0

105

Chipper, hand held

-

-

CNP043

1

112

100%

0

112

Saw, circular wood

-

-

CNP201

1

108

100%

0

108

Generator

[1]

-

CNP 103

1

95

100%

0

95

Air Compressor

-

-

CNP002

1

102

100%

0

102

 

 

 

 

 

 

 

Total

115

 

 

 

 

 

 

 

 

 

Fabrication of steelwork (For Chlorination Plant Only)

 

 

 

 

 

Powered Mechanical Equipment

 

 

TM Ref./

No. Items

SWL/Item

On-time

Noise Barrier

Total SWL

(PME)

 

 

other Ref.

 

dB(A)

%

Reduction

dB(A)

Backhoe

[1]

-

C8/33

1

102

100%

0

102

Mobile Crane

[1]

-

C7/114

1

101

100%

0

101

Lorry

[1]

-

C3/59

1

105

100%

0

105

Generator

[1]

-

CNP 103

1

95

100%

0

95

Air Compressor

-

-

CNP002

1

102

100%

0

102

 

 

 

 

 

 

 

Total

109

Note: (1) Use of Quiet PME

 

 

 

 

 

 

 

 

         Except for piling work and fabrication of steelwork, a duplicate set of PME is assumed for construction of chlorination plant and day tank.

 

 

 

 

 

 

 

 

 

 

 

Calculation of Construction Noise Levels at Representative NSR - Unmitigated Scenario

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSR: P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Chlorination Plant)

 

 

 

2008

2009

 

SWL

Distance

SPL

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

124

330

68

68

68

68

68

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

124

330

68

 

 

 

 

68

68

68

 

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

121

330

65

 

 

 

 

 

 

65

65

65

65

 

 

 

 

 

 

 

 

 

Fabrication of steelwork

117

330

62

 

 

 

 

 

 

 

 

62

62

62

62

62

62

62

 

 

 

 

Installation of E&M equipment #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

-

 

Testing and commissioning #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

 

Total SPL, dB(A)

68

68

68

68

68

68

70

65

67

67

62

62

62

62

62

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSR: P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Day Tank)

 

 

 

2008

2009

 

SWL

Distance

SPL

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

124

530

64

64

64

64

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

124

530

64

 

 

 

 

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piling (probably mini-pile)

118

530

58

 

 

 

 

 

58

58

58

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

121

530

61

 

 

 

 

 

 

 

 

61

61

61

61

 

 

 

 

 

 

 

Installation of E&M equipment #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

-

-

 

 

 

 

 

Testing and commissioning #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

-

-

-

 

Total SPL, dB(A)

64

64

64

64

64

58

58

58

61

61

61

61

62

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cumulative SPL at NSR P1 (Chorination Plant + Day Tank)

 

70

70

70

70

70

69

70

66

68

68

64

64

65

62

62

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

# As advised by DSD, no PME would be required for installation of E&M equipment and testing & commissiong

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Calculation of Construction Noise Levels at Representative NSR - Mitigated Scenario

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSR: P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Chlorination Plant)

 

 

 

2008

2009

 

SWL

Distance

SPL

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

119

330

64

64

64

64

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

119

330

64

 

 

 

 

64

64

64

 

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

115

330

60

 

 

 

 

 

 

60

60

60

60

 

 

 

 

 

 

 

 

 

Fabrication of steelwork

109

330

54

 

 

 

 

 

 

 

 

54

54

54

54

54

54

54

 

 

 

 

Installation of E&M equipment #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

-

 

Testing and commissioning #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

 

Total SPL, dB(A)

64

64

64

64

64

64

65

60

61

61

54

54

54

54

54

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSR: P1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Day Tank)

 

 

 

2008

2009

 

SWL

Distance

SPL

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Site formation & site establishment

119

530

60

60

60

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Excavation and backfilling

119

530

60

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Piling (probably mini-pile)

116

530

56

 

 

 

 

 

56

56

56

 

 

 

 

 

 

 

 

 

 

 

Erection of formwork, reinforcement fixing & concreting

115

530

56

 

 

 

 

 

 

 

 

56

56

56

56

 

 

 

 

 

 

 

Installation of E&M equipment #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

-

-

 

 

 

 

 

Testing and commissioning #

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

-

-

-

-

 

Total SPL, dB(A)

60

60

60

60

60

56

56

56

56

56

56

56

-

-

-

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cumulative SPL at NSR P1 (Chorination Plant + Day Tank)

 

65

65

65

65

65

65

66

61

62

62

58

58

54

54

54

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

# As advised by DSD, no PME would be required for installation of E&M equipment and testing & commissiong