Annex B4-3 |
|
|
|
|
|
|
|
|
|
Sound
Data provided by EPD's Landfill Contractor for the Existing SENT Landfill |
|
|
|
Activity |
Activity
Description |
Sound Pressure Level (SPL), dB(A) [1] |
Distance from source (d1),m |
Sound Power Level (SWL), dB(A) [2] |
Quantity |
|
|
|
|
|
|
|
|
|
|
|
Fixed plants |
Landfill Gas Power Plant Room -
Enginees |
- |
- |
88.0 |
|
2 [3] |
|
|
Blower Room No. 1 - Blowers |
- |
- |
101.0 |
|
5 [4] |
|
|
Blower Room No. 1 - Compressors |
73 |
3 |
90.5 |
|
2 |
|
|
Blower Room No. 2 - Blowers |
- |
- |
101.0 |
|
4 [5] |
|
|
Blower Room No. 2 - Compressor |
65 |
3 |
82.5 |
|
1 |
|
|
Air Compressors |
65 |
3 |
82.5 |
|
2 |
|
|
|
|
|
|
|
|
|
|
Notes: |
|
[1] |
Sound Pressure Level and
Sound Power Levels for the fixed plant items are provided by EPD's landfill
contractor for the existing SENT Landfill. |
|
[2] |
Sound Power Level for air
compressor = SPL + 10*log(2p(d1)2). |
|
[3] |
Only one of the two
engines of the landfill gas power plant will be operated at any one time. |
|
[4] |
There will have a total
of 5 blowers inside Blower Room No. 1, only 3 of them will be operated at any
one time, the other 2 will be for standby purpose. |
|
[5] |
There will have a total
of 4 blowers inside Blower Room No. 2, only 2 of them will be operated at any
one time, the other 2 will be for standby purpose. |
|
|
|
|
|
|
|
|
|
|
|
|