NSP |
Last
section |
Phase
1 |
Phase
2 |
Phase
3 |
Phase
4 |
Phase
5 |
Phase
6 |
Landfill
Gas Power Plant |
Blower
Room |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Distance: |
### |
### |
### |
### |
1850 |
1850 |
1800 |
1650 |
2500 |
2500 |
|
Annex
B5-3 |
|
|
|
Noise
Assessment for Operation of Landfill Extension |
|
|
|
|
|
|
NSR: |
A86R1 |
Planned Residential
Development in Area 86 |
|
|
|
|
|
|
|
SWL, dB(A) [1] |
% on time |
Distance from source to NSR (d2),m |
Corr. For (dB(A)) |
Predicted Noise Level (dB(A)) |
|
|
|
|
|
Distance [2] |
Façade |
Topo |
Time |
|
|
Activity |
No. |
Activity Description |
|
|
Fixed plants |
1 |
Landfill Gas Power Plant Room -
Engine 1 [3] |
95 |
50% |
2500 |
-76 |
3 |
-10 |
-3 |
|
9 |
|
|
|
8 |
|
2 |
Landfill Gas Power Plant Room -
Engine 2 [3] |
95 |
50% |
2500 |
-76 |
3 |
-10 |
-3 |
|
9 |
|
|
|
8 |
|
3 |
Blower Room No. 1[4] - Blower 1 |
108 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
25 |
|
|
|
321 |
|
4 |
Blower Room No. 1[4] - Blower 2 |
108 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
25 |
|
|
|
321 |
|
5 |
Blower Room No. 1[4] - Blower 3 |
108 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
25 |
|
|
|
321 |
|
6 |
Blower Room No. 1 - Compressor 1 |
100 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
17 |
|
|
|
51 |
|
7 |
Blower Room No. 1 - Compressor 2 |
100 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
17 |
|
|
|
51 |
|
8 |
Blower Room No. 2[5] - Blower 1 |
108 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
25 |
|
|
|
321 |
|
9 |
Blower Room No. 2[5] - Blower 2 |
108 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
25 |
|
|
|
321 |
|
10 |
Blower Room No. 2 - Compressor 1 |
100 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
17 |
|
|
|
51 |
|
11 |
Air Compressor 1 |
100 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
17 |
|
|
|
51 |
|
12 |
Air Compressor 2 |
100 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
17 |
|
|
|
51 |
|
13 |
Leachate Treatment Plant [6] |
75 |
100% |
2500 |
-76 |
3 |
-10 |
0 |
|
-8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Total Predicted Noise Level, dB(A) |
|
33 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Distance from source to NSR (d2),m |
Corr. For |
Corr. For |
Corr. For |
Predicted Construction Noise Level By Quarter (dB(A)) |
Max. |
|
|
|
|
SWL |
Distance |
façade |
Topo |
2012 |
2013 |
2014 |
2015 |
2016 |
2017 |
2018 |
2019 |
CNL |
|
Activity |
No. |
Activity Description |
dB(A) |
dB(A) |
dB(A) |
dB(A) |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
Q1 |
Q2 |
Q3 |
Q4 |
dB(A) |
|
Landfilling Operation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
#REF! |
#REF! |
|
|
Phase 1 |
6a |
Deposition and compaction of waste |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1850 |
-73 |
3 |
0 |
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase 2 |
6a |
Deposition and compaction of waste |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase 3 |
6a |
Deposition and compaction of waste |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase 4 |
6a |
Deposition and compaction of waste |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase 5 |
6a |
Deposition and compaction of waste |
117 |
1800 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1800 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48 |
48 |
48 |
48 |
|
|
|
|
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1800 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
Phase 6 |
6a |
Deposition and compaction of waste |
117 |
1650 |
-72 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
6b |
Placement of intermediate cover |
118 |
1650 |
-72 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48 |
48 |
48 |
48 |
|
|
|
|
|
|
|
6c |
Removal of intermediate cover |
117 |
1650 |
-72 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
48 |
48 |
48 |
48 |
|
|
|
|
|
|
All
over construction, operation & restoration |
7a |
Site
housekeeping |
109 |
1600 |
-72 |
3 |
0 |
|
|
|
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
|
|
|
|
7b |
Vehicle
maintenance |
102 |
1600 |
-72 |
3 |
0 |
|
|
|
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
33 |
|
|
|
|
Phase
1 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1850 |
-73 |
3 |
0 |
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase
2 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase
3 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase
4 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1850 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Phase
5 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1800 |
-73 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
46 |
46 |
46 |
46 |
|
|
|
|
|
|
|
|
|
|
Phase
6 |
8 |
Placement
of daily cover after 2300 hours |
116 |
1650 |
-72 |
3 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
47 |
47 |
47 |
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Predicted Noise Level during day and evening time (0700 -
2300 hrs), dB(A) |
|
|
|
41 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
53 |
53 |
53 |
53 |
41 |
41 |
|
53 |
|
|
|
|
|
|
|
Predicted Noise Level during night-time (2300 - 0700 hrs),
dB(A) |
|
|
|
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
47 |
47 |
47 |
47 |
|
|
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cumulative Noise Level during day and evening time (0700 -
2300 hrs), dB(A) |
|
|
41 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
52 |
53 |
53 |
53 |
53 |
41 |
41 |
|
53 |
|
|
|
|
|
|
|
Cumulative Noise Level during night-time (2300 - 0700 hrs),
dB(A) |
|
|
33 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
46 |
47 |
47 |
47 |
47 |
33 |
33 |
|
47 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes: |
|
|
|
|
|
|
|
|
[1] |
Reference was made
to the GW-TM for the sound power
levels (SWLs) of the fixed plant items that were similar in nature to certain
PME in the aforementioned GW-TM. Comparing with the
sound data provided by the operator of the existing SENT Landfill for th |
|
[2] |
Distance Correction =
-10*log(2p(d2)2) |
|
|
|
|
|
[3] |
Only one of the two
engines of the landfill gas power plant will be operated at any one time. |
|
|
[4] |
There will have a total
of 5 blowers inside Blower Room No. 1, only 3 of them will be operated at any
one time, the other 2 will be for standby purpose. |
|
[5] |
There will have a total
of 4 blowers inside Blower Room No. 2, only 2 of them will be operated at any
one time, the other 2 will be for standby purpose. |
|
[6] |
Reference was made to
the EIA Report for "North East New Territories (NENT) Landfill
Extension" (Register No.: AEIAR-111/2007) for the SWL of the leachate