7.1.1
This section presents the assessment of waste management
implications associated with the construction and operation of the Project.
7.1.2
Waste mitigation measures such as waste handling, storage and
disposal have been suggested in Sections 7.6 and 7.7.
7.2.1
According to Clause 3.4.7 of the EIA Study Brief, the waste
management criteria shall follow Annex 7 and Annex 15 of the Technical
Memorandum on Environmental Impact Assessment Process (EIAO-TM) and the
specified technical requirements in Appendix F of the EIA Study Brief.
7.2.2
The below Ordinances cover the treatment, handling and
disposal of waste for this Project:
·
Waste Disposal Ordinance (Cap. 354);
· Waste
Disposal (Chemical Waste) (General) Regulation (Cap. 354C);
· Waste
Disposal (Clinical Waste) (General) Regulation (Cap. 354O);
· Waste
Disposal (Charges for Disposal of Construction Waste) Regulation (Cap. 354N);
· Land
(Miscellaneous Provisions) Ordinance (Cap. 28);
· Public
Health and Municipal Services Ordinance (Cap. 132); and
· Public
Cleansing and Prevention of Nuisances Regulation (Cap. 132BK).
Waste Disposal Ordinance (Cap. 354)
7.2.3
The Waste Disposal Ordinance (WDO) prohibits any unauthorised
disposal of waste. Waste can only be disposed of at designed waste disposal
facilities licenced by the Environmental Protection Department (EPD) under the
WDO. Breach of this Ordinance can lead to a fine and/or imprisonment. The WDO
also stipulates the requirements for issuing licences for the collection and
transportation of waste.
Waste Disposal (Chemical Waste) (General) Regulation (Cap. 354C)
7.2.4
According to the definition under the Waste Disposal
(Chemical Waste) (General) Regulation, chemical waste includes scrap materials
or unwanted substances specified under Schedule 1 of the Regulation, if such a
substance or chemical occurs in such a form, quantity or concentration that
causes pollution or constitutes a danger to health or risk of pollution to the
environment. The Regulation provides regulations for chemical waste control,
and administers the possession, storage, collection, transportation and
disposal of chemical waste. EPD has also issued a ‘guideline’ document, the Code
of Practice on the Packaging, Labelling and Storage of Chemical Wastes (1992),
which details how the Contractor should comply with the regulations on chemical
waste.
Waste Disposal (Clinical Waste) (General) Regulation (Cap.
354O)
7.2.5
The WDO defines clinical waste as any waste substance
belonging to the groups in Schedule 8 of the WDO (Cap. 354) that is generated
in connection with practices or laboratories providing medical care or services
for those that require medical treatment, including pharmaceutical research.
Clinical waste does not include chemical or radioactive waste. Cap. 354O
provides the regulations for proper disposal and delivery of clinical waste
including the licenses required for its collection and disposal.
Waste Disposal (Charges for Disposal of Construction Waste)
Regulation (Cap. 354N)
7.2.6
Under the Waste Disposal (Charges for Disposal of
Construction Waste) Regulation, construction waste delivered to a landfill for
disposal must not contain more than 50% by weight of inert material;
construction waste delivered to a sorting facility for disposal must contain
more than 50% by weight of inert material; and construction waste delivered to
a Public Fill Reception Facility for disposal must consist entirely of inert
material.
Land (Miscellaneous Provisions) Ordinance (Cap. 28)
7.2.7
The inert portion of construction and demolition (C&D)
materials may be taken to public filling facilities including public filling
area, public filling barging points and stockpiling areas. These facilities
usually form part of land reclamation scheme and are operated by Civil
Engineering and Development Department (CEDD). The Land (Miscellaneous
Provisions) Ordinance requires that individuals or companies who deliver public
fill to the public filling facilities to obtain Dumping Licences. The licences
are issued by CEDD under delegated authority from the Director of Lands.
Public Health and Municipal Services Ordinance (Cap. 132)
7.2.8
Under the Public Health and Municipal Services Ordinance Cap.
132, waste management should include the prevention of obstruction of waste to
sewers and drains, and maintenance of sewers and drains by removing any
coverings from waste materials. Construction and operation phase shall prevent
any accumulation of waste leading to the obstruction and covering of any sewers
and drains.
Public Cleansing and Prevention of Nuisances Regulation (Cap. 132BK)
7.2.9
Waste management shall follow the general waste disposal
requirements stated under Cap. 132BK, which includes the prevention of litter
arising on streets and public places, disposal of MSW and other dangerous
goods. Works under the construction phase shall ensure no waste enters public
areas and dangerous waste as specified in the Ordinance is disposed in the
stipulated method. Waste streams in the operation phase shall be designed to
ensure all generated waste contained in waste bins and properly transferred to
the waste treatment/disposal site.
Other Relevant Guidelines
7.2.10
The following guidelines and documents also relate to waste
management and disposal in Hong Kong:
·
WBTC No. 2/93, Public Dumps;
· WBTC
No. 2/93B, Public Filling Facilities;
· WBTC
Nos. 4/98 and 4/98A, Use of Public Fill in Reclamation and Earth Filling
Projects;
· WBTC
No. 12/2000, Fill Management;
· WBTC
No. 19/2001, Metallic Site Hoardings and Signboards;
· WBTC
No. 12/2002, Specification Facilitating the Use of Recycled Aggregates;
· ETWB
TC(W) No. 19/2005, Environmental Management on Construction Sites;
· DEVB
TC(W) No. 6/2010, Trip Ticket System for Disposal of Construction and
Demolition Materials;
· DEVB
TC(W) No. 8/2010, Enhanced Specification for Site Cleanliness and Tidiness;
· DEVB
TC(W) No. 2/2011, Encouraging the Use of Recycled and other Green Materials in
Public Works Projects;
· DEVB
TC(W) No. 9/2011, Enhanced Control Measures for Management of Public Fill;
· CEDD
TC No. 11/2019, Management of Construction and Demolition Materials;
· Code
of Practice on the Packaging, Labelling and Storage of Chemical Wastes;
· Code
of Practice for the Management of Clinical Waste - Small Clinical Waste
Producers (June 2010);
· Code
of Practice on Asbestos Control – Preparation of Asbestos Investigation Report,
Asbestos Management Plan and Asbestos Abatement Plan;
· Code
of Practice on Asbestos Control – Safe Handling of Low Risk Asbestos Containing
Material;
· Code
of Practice on Asbestos Control – Asbestos Work Using Full Containment or Mini
Containment Method;
· Code
of Practice on Asbestos Control – Asbestos Work Using Glove Bag Method;
· ProPECC
PN2/97 Handling of Asbestos Containing Materials in Buildings;
· Code
of Practice on the Handling, Transportation and Disposal of Asbestos Waste;
· Project
Administration Handbook for Civil Engineering Works (2020 Edition);
· DEVB
Greening, Landscape and Tree Management Section, Guidelines on Yard Waste
Reduction and Treatment (July 2014);
· A Policy Framework for the Management of Municipal Solid Waste
(2005-2014);
· Waste Disposal Plan for Hong Kong (December 1989);
· Waste Reduction Framework Plan, 1998 to 2007;
· Waste Diversion Plan (2015);
· Hong Kong Blueprint for Sustainable Use of Resources 2013–2022;
and
· Hong
Kong Planning Standards and Guidelines, Chapter 9 (Section 6 – Waste
Management).
Project Administration Handbook
for Civil Engineering Works (2020 Edition)
7.2.11
According to the last paragraph of Section 4.1.3 in Chapter 4 of the “Project Administration Handbook for Civil
Engineering Works (2020 Edition)” published by CEDD, if a project generates
more than 50,000m3 of C&D materials, a Construction and
Demolition Materials Management Plan (C&DMMP) shall be submitted to PFC for
in principle approval prior to commencement of the detailed design stage. The
C&DMMP should be vetted and endorsed by the departmental Vetting Committee
before submitting it to the Public Fill Committee (PFC) for approval. The
C&DMMP shall be available in the later stage.
WBTC No.
2/93, Public Dumps
7.2.12
In accordance with policies related to C&D materials
disposal documented in the WBTC No. 2/93 Public Dumps, inert C&D materials
(i.e., public fill) should be transported to Public Fill Reception Facilities
(PFRFs) instead of disposing of at landfill.
ETWB TC(W) No. 19/2005, Environmental Management on
Construction Sites
7.2.13
ETWB TC(W) No. 19/2005 Environmental Management on
Construction Site specifies the Safety Management System for public works
contracts, which includes the procedures and requirements on waste management
and sets out the policy for contractor to prepare and implement an
Environmental Management Plan (EMP), which includes the Waste Management Plan
(WMP), for on-site sorting and waste reduction of C&D materials. The WMP
would then be submitted to the Project Engineer for approval.
Code of Practice for the
Management of Clinical Waste – Small Clinical Waste Producers (June 2010)
7.2.14
This Code of Practice has been developed under Cap. 354 and
Cap. 354O which covers the types of clinical wastes; the requirements for the
segregation, packaging and labelling of different types of clinical wastes;
storage of types of clinical wastes; collection and transportation of clinical
wastes; collection points and record keeping requirements. The management of
welfare facilities in operation phase shall make reference to these
requirements when dealing with the generation of specific types of clinical
waste.
7.3.1
The Proposed Development Area (PDA) has always been a golf
course since it first established in 1911. The area is 32 hectares, 18-hole
golf course with grasses, shrubs, thick tree foliage. The associated off-site
works area intended to provide infrastructures supporting the PDA development
are located on roads and cycling path in the residential neighbourhood of Choi
Po Court and Choi Yuen Estate. Construction wastes expected to generate from
Project development include C&D materials from site formation and site
clearance.
7.3.2
The PDA falls within the North District’s waste generation zone.
According to “Monitoring of Solid Waste in Hong Kong, 2020” by EPD, the
Municipal Solid Waste (MSW) generated from the North District, was
approximately 851 tonnes per day (tpd), which includes domestic waste and
commercial & industrial waste. The amount of construction waste arised from
the North District (2020) was approximately 215 tpd. The breakdown of the types
of waste arised from North District is summarised in Table 7.3.1. The
waste facilities currently serving the North District are summarised in Table
7.3.2.
Table
7.3.1 Breakdown of Solid Waste
Generation Arised from North District in 2020 Disposed at Landfills
District
|
Average Daily Quantity (tpd)
|
Domestic Waste (a)
|
Commercial & Industrial Waste (b)
|
Municipal Solid Waste (c) = (a) + (b)
|
Overall Construction Waste (d)
|
Total (c) + (d)
|
North
|
343
|
508
|
851
|
215
|
1,066
|
Table
7.3.2 Summary of Current Waste
Facilities Serving North District in 2020
Waste Facilities
|
Date of Commission
|
Design Capacity
|
Current Waste Intake
|
Public Fill
Reception Facilities
|
Tuen Mun Area 38 Fill
Bank
|
2003
|
5.1 Mm³
|
Approximately 12,057 tpd,
|
Strategic Landfills
|
North East New
Territories
(NENT), Strategic Landfill
|
June 1995
|
35 Mm³
|
6,000
tpd
|
Refuse Transfer
Stations
|
Shatin Transfer Station
(STTS), Refuse Transfer Station (to NENT)
|
October 1994
|
N/A
|
1,655 tpd
|
North West New Territories
Transfer Station (NWNTTS), Refuse Transfer Station (to WENT)
|
September 2001
|
N/A
|
1,260 tpd
|
Special Waste
Facilities
|
Chemical Waste
Treatment Centre (CWTC)
|
April 1993
|
100,000
tonnes chemical waste and clinical waste per year
|
N/A
|
Animal Waste Composting
Plant (AWCP)
|
2008
|
40 tpd
|
N/A
|
EcoPark / WEEE Park
Treatment and Recycling Facility
|
March 2018
|
30,000 tonnes of WEEE
per year
|
23,980 tonnes (2019)
|
O Park 1, Organic
Resources Recovery Centre (Siu Ho Wan)
|
July 2018
|
200 tpd of food waste
|
N/A
|
T Park, Sludge
Treatment Facility
|
April 2015
|
2,000 tpd
|
1,200 tpd
|
7.4
Assessment Approach
7.4.1
The waste management hierarchy is to minimise waste
generation. If waste generation cannot be avoided, a material/waste management
plan will be established prior to commencement of excavation and construction
work to outline the methods that can be incorporated into the project for waste
minimisation, including re-use, recycling, matching disposal with other
project, handling, storage, transportation and disposal of expected waste
materials.
7.4.2
With the proposed development located within a golf course
and large areas are to be excavated, it is anticipated turf grasses and topsoil
are to be stripped away from the area before site clearance and construction
work can take place. Contaminated soils will be remediated prior to any site
clearance activities and will be reused on-site. Excavated C&D materials
will also be used for reinstatement and/or backfilling as much as possible at
the site. Inert C&D materials that cannot be reused on-site will be sent to
the Public Fill Reception Facility. The waste management hierarchy is a concept
that shows the desirability of various waste management methods and comprises
the following in order of preference:
·
Avoidance;
·
Minimisation;
·
Recycling / reuse;
·
Treatment; and
·
Disposal.
7.4.3
The approach for assessing waste management implications are
outlined in Annex 7 of EIAO-TM. Whereas methods for assessing potential waste
management impacts during construction and operation phases of the Project
would be studied as per Annex 15 of EIAO-TM, which include the following:
·
Estimation of types and quantities of the waste generated and
fill to be imported;
·
Assessment of potential impacts from the management of waste with
respect to potential hazards, air and odour emissions, noise, wastewater
discharge and public transport;
·
Examination of the opportunities for reducing waste generation;
·
Identification of disposal options for each type of waste; and
·
Assessment of impacts on the capacity of waste collection,
transfer and disposal facilities.
7.4.4
Prior to considering the disposal options for various types
of waste, opportunities for reducing waste generation, on-site or off-site
re-use and recycling have been evaluated. Measures which can be taken in the
planning and design phases (i.e., by modifying the design approach) and in the
construction phase for maximising waste reduction have been separately
considered. The following design and construction methods have been adopted to
reduce construction waste:
·
Optimization of construction methods – Use of cut slope methods versus
L-shaped for construction of retaining structures on the housing site on Sub-Area
1, to minimise the excavation works required and to generate less excavated
volume.
·
Minimization of construction works – there will be no extensive
development at Sub-Area 2 to Sub-Area 3 with an aim to maintain the integrity
of existing ecological species and habitat conservation, and generate less
excavated volume.
·
No proposed works to be carried out in Sub-Area 4 to maintain the
integrity of existing ecological species and habitat conservation.
7.4.5
After considering all options and methods to reduce waste
generation and maximising re-use, the types and quantities of waste required to
be disposed of will be estimated and the disposal options for each type of
waste will be described.
7.4.6
The disposal options recommended for the generated waste in
this report have considered the result of the assessment. The impacts caused by
handling (including stockpiling, labelling, packaging and storage), collection,
and reuse / disposal of waste will be addressed and propose appropriate
mitigation measures.
7.5.1
The waste implication during construction and operation phases
include the following:
Construction
Phase
7.5.2
It is anticipated that the majority of C&D waste will be
generated from the following activities during the construction phase.
Public
Housing Site in Sub-Area 1
·
Site clearance (i.e., removal of turf grasses and topsoil, demolition
of existing structures such as staff quarters and carpark)
·
Site formation (i.e., construction of retaining structures)
·
Infrastructure (i.e., utilities, pipe laying and reinstatement,
internal road)
·
Building works (i.e., substructure and superstructure
construction)
·
Public Transport Interchange (PTI) structure and bus terminus
School
Site in Sub-Area 1
·
Site clearance (i.e., removal of turf grasses and topsoil,
demolition of existing structures such as quarters and carpark)
·
Site formation (i.e., construction of retaining structures)
·
Infrastructure (i.e., pipe laying and reinstatement)
·
Building works (i.e., substructure and superstructure
construction)
Recreational
Facilities to Support Recreational Activity in Sub-Area 2
·
Site clearance and formation (i.e., construction of recreational
facilities and ancillary facilities)
Landscaping Works in Sub-Areas 2 and 3
·
Landscaping and transplantation of trees in Sub-Areas 2 and 3
·
Under current plan, approximately 996 compensatory trees and 41
transplant trees
Infrastructure and
Associated Off-site Works Area
·
Roadworks including minor road modification on Ping Kong Road and
road junction improvement
·
Earthworks, temporary supports erection, utilities laying, concreting,
laying of sub-base materials and laying of bituminous or concrete surfacing
layers, construction of flood wall
·
Waterworks, sewerage and drainage works; construction of new
drainage pipes and flood wall, layering of sewers, fresh and flushing watermains
to support the development
7.5.3
Based on the current design, a variety of wastes are
anticipated to be generated during the construction phase that can be divided
into different key categories based on their composition and ultimate method of
disposal. The identified waste types include:
·
Construction and Demolition (C&D) materials (includes inert
and non-inert C&D materials);
·
Chemical waste; and
·
General refuse.
Asbestos-containing materials (ACMs)
may be present on the Project Site. An asbestos investigation shall be
undertaken to prior to the demolition of private properties and staff quarters
during construction phase. However, there will be no generation of
excavated/dredged sediment from the Project construction activities.
7.5.4
The types of waste during the construction phase are
summarised in Table 7.5.1.
Table 7.5.1 Waste Types and Sources in the Construction Phase of
the Project
Waste Types
|
Sources of Wastes
|
Example of Waste
|
Construction
and Demolition (C&D) materials
|
· Site clearance and site formation
· Construction and building works of the public
housing site and school site
· Recreational facilities and ancillary facilities
· Construction of public transport interchange (PTI) /
bus terminus
·
Associated road works and
infrastructure works
|
Inert C&D
materials:
·
Rocks;
·
Soft materials; and
·
Artificial hard materials.
Non-inert C&D
materials:
· Bamboo, timber, paper and plastic Other organic
material, including turf grasses and topsoil
|
Asbestos-Containing
Materials (ACMs)
|
· Generation of ACMs during building demolition
|
·
ACMs (subject to further
investigation by Asbestos Consultant)
|
Chemical
Waste
|
·
The operation and maintenance of the plant and mechanical
equipment
|
·
Fluorescent tubes, cleaning fluid (i.e., detergent), solvents,
waste lubricating oil and fuel
|
General
Refuse
|
·
On-site workforce
|
·
Food waste, aluminium cans, waste papers and containers
|
7.5.5
The construction phase of the Project will be implemented in
a number of development stages through a number of construction activities. The
anticipated timing for major construction activities in each development stage
is summarised in Table 7.5.2.
Table 7.5.2 Anticipated
Timing for Major Construction Activities in Each Development Stage
Development
Stage
|
Construction Activities and
Works
|
Anticipated Timing
|
Stage 1
|
Public
Housing Development in Sub-Area 1
· Site clearance and site formation
· Construction of internal roads
· Pipe works and utilities works
· Construction and building works of public
housing site
· Construction of public transport
interchange (PTI) and bus terminus
|
2024 - 2029
|
Stage 2
|
School Site
Development in Sub-Area 1
· Site clearance and site formation
· Construction of internal roads
· Pipe works and utilities works
· Construction and building works of school
site
|
2024-2028
|
Stage 3
|
Associated Road
Works Outside PDA
· Junction improvement works at Po Kin Road
/ Ping Kong Road
· Minor road improvement works at Ping Kong
Road
|
2024-2029
|
Stage 4
|
Associated
Infrastructure Works outside PDA
· Pipe works and utilities works
|
2024-2029
|
Stage 5
|
Recreational cum
Conservation Area in Sub-Areas 2 to 4
|
To be further reviewed
|
Construction and Demolition (C&D)
Materials
7.5.6
C&D materials contains a mixture of inert and non-inert
materials mainly generated from site clearance, site formation, infrastructure
(earthworks), building, landscape and tree transplanting, associated road works
and associated off-site works. Inert C&D materials generated would include
(but not limited to) rock, soil, concrete, asphalt, bitumen and granular
materials etc. that can be transported to Public Fill Reception Facility; while
non-inert C&D materials generated would include (but not limited to)
bamboo, timber, paper and plastic etc. that cannot be transported to Public
Fill Reception Facility. A summary of the C&D materials generated from the
key construction activities and recommended management option is summarised in Table
7.5.3.
7.5.7
The proposed public housing development and school site are
located in Sub-Area 1. The site is estimated to provide a maximum of 12,000
flats, accommodating a population of approximately 33,600. Alongside with a
number of social welfare facilities, PTI and construction of school site are proposed
to serve the population. Recreational facilities and ancillary facilities to
support recreational activity will be provided in Sub-Area 2. Waste is expected
to be generated throughout the construction stage for these proposed activities.
The major construction activities that generates C&D materials are listed
as follows:
·
Site clearance and formation for public housing development;
·
Site formation for the kindergarten;
·
Site formation for the school;
·
Site formation for the PTI;
·
Site formation for the list of welfare facilities;
·
Site formation for the recreational facilities and ancillary
facilities; and
· Foundation
construction.
Table 7.5.3 Estimated
C&D Materials Generated from Different Construction Phases (Preliminary
Estimate)
Activities / Phase
|
Timeline
|
Location
|
Inert C&D materials
(m3)
|
Non-inert C&D
materials (m3) [4]
|
Total C&D materials
(m3)
|
Public Housing and
School Site Development in Sub-Area 1
|
Site Clearance and Site Formation
for Public Housing Site and School Site
·
Removal of turf
grasses and topsoil
·
Demolition of
existing structures such as quarters and carpark
·
Cutting and
filling existing ground profiles for platform formation
·
Construction of
retaining structures
|
2024 to 2029
|
Public Housing Development
|
170,000
|
200,000
|
370,000
|
2024 to 2028
|
School Site Development
|
50,000
|
10,000
|
60,000
|
Building Works for Public Housing Site
·
Foundation
works: piling
·
Superstructure:
erection of precast concrete elements and in-situ concreting work
·
Sub-Area 1
landscaping works
|
2024 to
2029
|
Public Housing
Development
|
220,000
|
50,000
|
270,000
|
Building Works for School
Site
·
Foundation
works: shallow foundation
·
Superstructure:
erection of precast concrete elements and in-situ concreting work
·
Sub-Area 1
landscaping works
|
2024 to 2028
|
School Site Development
|
10,000
|
4,000
|
14,000
|
Infrastructure and Road
Works (Associated Off-site Works Area including Road Works and Infrastructure
Works)
|
·
Roadworks
including minor road modification on Ping Kong Road and road junction
improvement
·
Earthworks,
temporary supports erection, drainage and sewer utilities laying, concreting,
laying of sub-base materials and laying of bituminous or concrete surfacing
layers, construction of flood wall
|
2024 to 2029
|
Associated Road Works and
Infrastructure Works outside the PDA
|
170,000
|
10,000
|
180,000
|
Activities / Phase
|
Timeline
|
Location
|
Inert C&D materials
(m3)
|
Non-inert C&D
materials (m3) [4]
|
Total C&D materials
(m3)
|
Recreational cum
Conservation Area
|
Site Clearance and Site
Formation
·
Removal
of turf grasses and topsoil
·
Landscaping
works, approximately 996 compensatory trees and 41 transplanted trees are
proposed in Sub-Area 2 to Sub-Area 3
|
To be further reviewed
|
Sub-Areas 2 to 4
|
N/A
|
56,000
(to be backfilled in-situ if
clean for trees transplanting)
|
56,000
|
Total
|
620,000
|
330,000
|
950,000
|
Inert
C&D Materials
|
Non-inert
C&D Materials
|
C&D
Materials
|
With Management Options
|
On-site reuse: 50,000
Public Fill Reception Facility:
570,000
|
On-site reuse: 56,000
Reuse / recycle prior to off-site
disposal:
66,000 (using 20% recycling rate)
Landfill:
208,000
|
Inert C&D materials to PFRF:
570,000
Inert C&D materials for
on-site reuse:
50,000
Non-inert C&D materials for
on-site reuse:
56,000
Non-inert C&D materials for
recycling:
66,000
Non-inert C&D materials to
landfill:
208,000
|
Notes:
[1] “Rocks” includes all grade rock.
[2] “Soft Material” includes, but not limited to excavated soil, fill, etc.
[3] “Artificial Hard Material” includes, but not limited to, broken concrete,
asphalt, bitumen and granular materials, etc.
[4] “Non-inert C&D materials” includes, but not limited to turf grasses
(top layer of grass), topsoil (top 10cm layer of soil), bamboo, timber, paper
and plastic, etc.
[5] A preliminary figure as advised by the Project Engineer at the time of
this report.
N/A Not Available
C&D Materials generated from Site Clearance and
Site Formation at Sub-Area 1
7.5.8
The site clearance and site formation will be one of the
major sources of C&D materials generated by Project activities. Site
clearance and site formation wastes will mainly be generated from demolishing
of existing structures, tree felling and preparation of the existing ground
surface including vegetation, top soil, broken concrete and asphalt, and
construction of internal roads, and PTI. Inert materials such as earth soil,
rock and concrete, and non-inert materials such as topsoil, timber, vegetation,
packaging waste and other organic materials are anticipated.
7.5.9
Total estimated C&D materials from site clearance and
site formation is 430,000 m3 estimated of which 220,000 m3
are inert C&D materials and 210,000 m3 are non-inert C&D
materials. Inert and non-inert C&D materials will be reused on-site as much
as possible prior to final disposal. Excess inert C&D materials will be disposed
of at Public Fill Reception Facility while excess non-recyclable non-inert
C&D materials will be disposed of at landfill.
C&D Materials generated from Building Works
for Public Housing and School Site
7.5.10
Building works at the public housing and school site are
expected to be the second major source of C&D materials generation. The housing
site includes foundation, superstructure and infrastructures, and landscaping
works. Operations entail piling works, erection of precast concrete elements
and in-situ concreting work. Inert materials such as soil, rock and
concrete, non-inert materials such as timber, vegetation, packaging waste and
other organic materials are anticipated. Total amount of C&D materials from
building works for the public housing site is estimated at 270,000 m3,
in which 220,000 m3 of inert materials and 50,000 m3 of non-inert
materials.
7.5.11
The school site also includes foundation, superstructure and
infrastructures, and landscaping works. Operations entail shallow foundation,
erection of precast concrete elements and in-situ concreting work. Inert
materials such as soil, rock and concrete, non-inert materials such as timber,
vegetation, packaging waste and other organic materials are anticipated. Total
estimated C&D materials from building works of school site is 14,000 m3,
in which 10,000 m3 are inert C&D materials and 4,000 m3
are non-inert C&D materials.
7.5.12
Inert and non-inert C&D materials will be reused on-site
as much as possible prior to final disposal. Excess inert C&D materials
will be disposed of at Public Fill Reception Facility while excess
non-recyclable non-inert C&D materials will be disposed of at landfill.
C&D Materials
generated from Landscaping and Tree Transplantation Works
7.5.13
Landscaping works are proposed in Sub-Area 2 to Sub-Area 3 of
the PDA, which consist of landscape and tree transplantation activities, with
an aim to further preserve ecological value at these Sub-Areas. Non-inert
C&D materials is estimated at 50,000 m3 and is expected to be
entirely backfilled in-situ in the landscaping process, assuming it is
clean soil. If the soil requires remediation, imported fill or excavated
materials from other on-site activities will be used for backfilling and the
imported fill is expected at 50,000 m3.
C&D Materials
generated from the Recreational Facilities at Sub-Area 2
7.5.14
Recreational facilities and ancillary
facilities to support the open space consisting of a 1-storey building may be
provided in the northern edge of Sub-Area 2. Provision of a prefabricated
building is recommended for the 1-storey building. No site formation is
anticipated from the recreational facilities hence inert C&D material is
not anticipated. Non-inert C&D materials is estimated at 6,000 m3
and is expected to be entirely backfilled in-situ in the landscaping
process as mentioned above.
C&D Materials generated
from Infrastructure and Associated Off-site Works
7.5.15
C&D materials to be generated from infrastructure
includes roadworks, earthworks and waterworks. Roadworks include road
modifications on Ping Kong Road and road junction improvement. Earthworks
include temporary supports erection, utilities laying, concreting, laying of
sub-base materials and laying of bituminous or concrete surfacing layers, and
construction of flood wall.
7.5.16
Waterworks, sewerage and drainage works include the
construction of new drainage pipes and flood wall, layering of sewers and
laying of watermains to support the development. Inert C&D materials such
as soil, rock and concrete; non-inert C&D materials such as timber,
vegetation and packaging waste are anticipated.
7.5.17
For infrastructure and associated off-site works, it is
estimated that the quantity of C&D materials is approximately 180,000 m3,
of which 170,000 m3 are inert C&D materials and 10,000 m3
are non-inert C&D materials. Inert and non-inert C&D materials will be
reused on-site as much as possible prior to final disposal. Excess inert
C&D materials will be disposed of at Public Fill Reception Facility while
excess non-recyclable non-inert C&D materials will be disposed of at
landfill.
On-site reuse of inert C&D materials
7.5.18
The Contractor is responsible for segregating the inert
C&D materials from the non-inert C&D materials for on-site reuse. In
order to minimise the impact resulting from collection and transportation of
inert C&D materials for off-site disposal, the inert C&D materials
particularly the excavated materials would be reused on-site as fill materials
as far as practicable.
Surplus inert C&D materials to Public Fill
Reception Facilities
7.5.19
On-site reuse of surplus inert C&D materials will be
adopted as far as possible and delivery to PFRF will be taken as the last
resort. The estimated amount of surplus C&D materials to be reused on-site
is 50,000 m3. In the case that on-site reuse is not possible, the
Contractor is responsible for the transfer of the surplus inert C&D
materials to closest PFRF operated by CEDD, located in Tuen Mun Area 38 Fill
Bank. The estimated amount of surplus C&D materials to be transported to
PFRF are 570,000 m3 (based on the assumption of 9% reuse rate). Materials
transported to PFRF should entirely be inert C&D materials consist of earth
soil and concrete only. The materials shall be free from plastics, chemical
waste, industrial metals and other materials that are considered as non-inert
C&D materials. A C&DMMP is required as the estimated quantity of
C&D materials to be generated is over 50,000 m3, and according to Section 4.1.3 of the PAH, the proposed Project is not classified
as “designated” projects under Schedule 2 of the EIAO but is generating surplus
C&D materials in excess of 300,000 m3 – the C&DMMP shall be
submitted to PFC in principal approval prior to commencement of the detailed
design stage. The C&DMMP should be vetted and endorsed by the departmental
Vetting Committee before submitting it to PFC for approval. As such, the
C&DMMP shall be available in a later stage.
Non-inert C&D
materials
7.5.20
The Contractor should separate the non-inert
C&D materials from the inert C&D materials on-site. It is recommended
to segregate recyclable materials (i.e., metal) from the non-inert C&D
materials for collection by reputable recyclers. The remaining non-recyclable
waste materials will be disposed of at designated landfill sites by a waste
collector. The contractor may transport the non-inert C&D materials
directly to the North East New Territories (NENT) Landfill or to Refuse
Transfer Stations (closest ones being Shatin Transfer Station (STTS) and North
West New Territories Transfer Station (NWNTTS)). The Contractor will be
requested to use the shortest route to the waste disposal site with minimal environmental
concerns. In order to prevent any adverse environmental impacts arising from
poor management of non-inert materials, mitigation measures in Section 7.6
should be referred to. This includes the proper storage of waste, minimization
of waste leakage to surrounding environment and the intermittent transport of
waste to designated waste treatment facilities.
Turf Grasses and Topsoil (as other organic
materials under non-inert C&D materials)
7.5.21
Each and every golf course that exists has some form of vegetation.
Vegetation comes in many different forms and typically consists of a diverse
landscape including the tee, fairway, rough, trees, and green. For vegetation
growing purposes there are three main soil compositions: sand, silt and clay.
Turf grass consists of the top layer of grass only, whereas topsoil consists of
the soil layer (<10 cm) under the turf grass.
7.5.22
Excavated turf grass and topsoil will be treated as other
organic materials under non-inert C&D materials, to be backfilled in-situ
for landscaping and tree transplanting activities (as mentioned in Section
7.5.13 to 7.5.14), with disposal of at landfills as last resort.
Asbestos-Containing Materials (ACMs)
7.5.23
Asbestos is widely used in the construction industry before
the early 1980’s for fireproofing, thermal and electrical insulation and in
sound absorption materials. However, asbestos is currently recognised as
hazardous materials, due to its etiological effects on human respiratory
system.
7.5.24
As the proposed Project involves the demolition of some
building and structures that were built before 1980’s, ACMs may be present in
the buildings of FGC areas. Thus, ACMs which may be disturbed during demolition
activities, should be removed and disposed of in a proper manner prior to
asbestos removal, so as to avoid the release of harmful asbestos fibres into
the environment and minimise potential hazard.
7.5.25
All ACMs if confirmed to be present within the existing
premises must be removed and disposed of in accordance with the Air Pollution
Control Ordinance and the Waste Disposal Ordinance prior to the
demolition work. A Registered Asbestos Consultant and Registered Asbestos
Laboratory shall be engaged to conduct investigation for the presence of ACMs.
7.5.26
An Asbestos Investigation Report, an Asbestos
Abatement Plan (AAP) (if required) and a notification of commencement of
asbestos abatement works shall be submitted to EPD at least 28 days before the
asbestos abatement works commences. Also, the removal of ACMs should be carried
out by a Registered Asbestos Contractor according to the approved AAP under the
supervision of a Registered Asbestos Consultant. The asbestos wastes generated
shall be disposed of by a licensed waste collector in compliance with the Waste
Disposal Ordinance.
Chemical
Waste
7.5.27
Chemical waste arising during the construction phase would
induce environmental, health and safety hazards if not stored and disposed of
in an appropriate manner as stipulated in the Waste Disposal (Chemical Waste)
(General) Regulations. The potential hazards include:
·
Toxic effects to workers;
· Adverse
impacts on water quality from spills; and
· Fire
hazards.
7.5.28
The maintenance and servicing of construction site and
equipment may generate chemical waste such as fluorescent tubes, cleaning fluid
(i.e., detergent), solvents, waste lubricating oil and fuel. Vehicle
maintenance may also involve the use of a variety of chemicals, oil and
lubricants including heavy duty cleaners, organic solvents, degreasers, brake
fluids, battery acid and soldering fluids.
7.5.29
The amount of chemical wastes that would generate from the
construction activities depends on the Contractor’s on-site maintenance
requirements and the equipment being used. However, based on the scale of the
Project, it is estimated that the quantity of such chemical waste would be in
the order of several hundred litres per month. The amount of chemical waste to
be generated will be quantified in the Waste Management Plan (WMP) to be
prepared by the Contractor for the site as part of the Environmental Management
Plan (EMP) and submitted to the Architect / Engineer for approval prior to
construction work in accordance with ETWB TC(W) 19/2005.
7.5.30
Storage, handling, transport and disposal of chemical waste
should be arranged in accordance with the Code of Practice on the Packaging,
Labelling and Storage of Chemical Waste published by the EPD. Chemical waste
should be collected by a licenced chemical waste collector and to be disposed
of at a licenced chemical waste treatment and disposal facility. Wherever
possible, opportunities for the reuse and recycling of materials will be taken.
Provided that the handling, storage and disposal of chemical waste are in
accordance with the requirements stated in the above legislations/regulations
with regards to storage and collection of chemical waste, potential
environmental impacts (including potential hazard, air and odour emissions,
noise, wastewater discharge and public transport) are not expected. Mitigation
and control requirements for chemical waste are detailed in Section 7.6.
General Refuse
7.5.31
The construction workforce will generate refuse comprising
food scraps, waste paper and empty containers during the construction period.
Release of general refuse into roadside gullies or surface channels is not
permitted as the introduction of these wastes are likely to have detrimental
effects to the environment. Such refuse shall be properly managed, and
intentional or accidental release to the surrounding environment must be
avoided. General refuse shall first be sorted via tri-coloured waste bins for on-site
segregation of recyclables. Non-recyclable general waste shall be disposed of
in general refuse bins. Disposal of refuse at sites other than approved waste
transfer or disposal facilities will be prohibited. Effective collection of
site waste will be required to prevent waste materials being blown around by
wind, flushed or leached into the river or marine environment, or creating an
odour nuisance or pest & vermin problems. Waste storage areas shall be well
maintained and cleaned regularly. Since the information on the number of
workers working on-site is not yet available at this preliminary stage, a
maximum of 200 workers working simultaneously is assumed. In the case of
estimating the general refuse generation rate, the per capita disposal rate of
0.91 kg per worker per day for domestic waste shall be taken. It is
therefore estimated that the daily amount of general refuse that would be
generated is approximately 182 kg. Adverse impact on the capacity of waste
collection, transfer and disposal facilities is not anticipated as the amount
of general refuse is limited.
7.5.32
Provided that the mitigation measures outlined in Section
7.6 are adopted, the potential environmental impacts caused by the storage,
handling transport and disposal of general refuse are expected to be minimal.
It is recommended that general refuse should be collected on a daily basis for
disposal. With the proper implementation of the recommended mitigation
measures, potential environmental impacts (including potential hazard, air and
odour emissions, noise, wastewater discharge and public transport) are not
expected.
Temporary Stockpiling
Areas
7.5.33
As shown in Table 7.5.3, inert C&D materials
generated from site clearance and site formation works have to be temporarily
stored within the Project site over the course of the different phases of the
Project. Since the Project will be implemented in stages, temporary stockpiling
areas have been identified to store the C&D materials for reuse under the
Project and the details can be referred to the C&DMMP.
7.5.34
The storage and stockpiling of C&D materials prior to utilisation
on-site may contribute to the generation of dust, visual impacts from
unsightliness and water quality impacts from runoff. The disposal of C&D
materials also has the potential to result in noise and dust impacts from
loading and unloading and emissions from haul vehicles. Mitigation and control
requirements for C&D materials are detailed in Sections 7.6.
Provided that the handling, storage and disposal of C&D materials are in
accordance with these requirements, the potential waste management
implications, including potential hazards, air and odour emissions, noise and
wastewater discharge, associated with handling, storage and disposal of C&D
materials during the construction phase of the Project are not expected.
7.5.35
The handling arrangement and stockpiling areas of other
wastes identified have been evaluated in Section 7.5. Provided that the
mitigation measures outlined in Section 7.6 are adopted, the potential
environmental impacts caused by the storage, handling transport and disposal of
the wastes generated from the Project are expected to be minimal.
Transportation Arrangement
for Waste Disposal during Construction Phase
7.5.36
Land transport should be utilised to deliver and dispose of
the wastes generated from the Project area to the designated disposal outlets.
No barging points or conveyor systems will be established in the Project area.
It is anticipated that a maximum of 30 vehicles per day for transporting the
wastes identified during the construction phase of the Project (year 2024 to
2029). The frequency of trucks for inert C&D materials enroute to Tuen Mun
Area 38 Fill Bank PFRF is estimated at 16 vehicles per day during the
construction phase (Year 2024 to 2029). The disposal route will be via Fanling
Highway, Yuen Long Highway, Tuen Mun Road, Wong Chu Road and Lung Mun Road. The
transportation routings may change subject to the actual traffic conditions of
the roads. Nevertheless, with the implementation of appropriate mitigation
measures (i.e., using water-tight containers and covered trucks), no adverse
environmental impacts are expected due to the transportation of waste. Table
7.5.4 summarises the waste types, handling procedures and the tentative
transportation routings of the wastes identified during construction phase.
Operation Phase
7.5.37
The proposed PDA development consists of the following
facilities (subject to final layout and project design parameters can be
referred to Chapter 2 of the EIA Report):
·
12,000 Public Housing Flats (12 blocks serving a population of
approximately 33,600);
· Carpark;
· Public
Transport Interchange (PTI);
· Schools
(Special School and 24-classroom Kindergarten); and
· Welfare
Facilities consisting of
o 100-place
Hostel for Severely Mentally Handicapped Persons (HSMH);
o 100-place Day
Activity Centre (DAC);
o 50-p Hostel for
Moderately Mentally Handicapped Persons (HMMH);
o 50-p Hostel for
Severely Physically Handicapped Persons (HSPH);
o 30-p Supported Hostel
for Mentally Handicapped Persons [SHOS(MH)];
o 120-p
Integrated Vocational Rehabilitation Services Centre (IVRSC);
o Neighbourhood
Elderly Centre (NEC);
o 100-p Child
Care Centre (CCC);
o 100-p
Residential Care Home for the Elderly (RCHE) cum 30-p Day Care Unit (DCU);
o One Integrated
Home Care Services Team;
o 60-p Day Care
Centre for the Elderly (DE); and
o 96-p
Residential Child Care Centre (RCCC).
7.5.38
During the operation phase, the following types of waste
shall be generated:
·
General refuse;
· Clinical
waste; and
· Chemical
waste.
7.5.39
A breakdown of waste arising during the operation phase are
summarised in Table 7.5.5.
Table 7.5.5 Waste Types and Sources in the Operation Phase of
the Project
Waste Types
|
Sources of waste
|
Examples
|
General Refuse
|
·
Residents from public housing
(33,600-person)
·
Residential housing employee
(120-person)
·
Staff and students from Kindergarten
and School (1523-person)
·
Welfare facilities for the
disabled and elderly and the employees (1030-person)
·
Staff from carpark, passengers
of PTI, users of retail and facilities (1159-person)
|
·
General refuse
·
Recyclable waste in tri-coloured
recycling bins – i.e., paper, plastic and metal
·
Food waste
|
Clinical Waste
|
·
100-p RCHE cum 30-p DCU (130-person)
|
As defined in WDO:
·
Group 1 – Used or contaminated
sharps
·
Group 2 – Laboratory waste
·
Group 3 – Animal and Human
tissues
·
Group 4 – Infectious materials
·
Group 5 – Dressings contaminated
with blood
·
Group 6 – Other wastes
|
Chemical Waste
|
·
Maintenance
activities in the proposed developments
including welfare and housing
·
Maintenance of vehicles car park
block
|
·
Cleaning products
·
Fluorescent light bulbs
·
Hazardous waste containers i.e.,
cooling towers, emergency generator lubrication fluids, paints
|
General Refuse
7.5.40
Since the proposed development is a housing estate, school
and welfare facilities, a majority of waste shall be domestic waste generated
by residents, school staff and students, housing management, welfare facilities
users and employees, and retail facilities. This includes general refuse such
as plastic, paper, aluminium, and food packaging. According to the latest
statistics published by EPD in 2020, the per capita domestic waste disposal rate
was 0.91 kg per person per day.
Based on said waste generation rate and the estimated population (37,432 altogether
in public housing, school staff and students, welfare facilities, carpark
staff, retail facilities users, and passengers from PTI), the daily domestic
waste generation is estimated at 34,063 kg (~34 tpd). The general refuse should
be recycled as far as possible through the placement of recycling bins throughout
the housing estate, welfare and retail facilities, and PTI. The remaining
refuse should be collected by waste collectors and disposed of at landfills.
Clinical Waste
7.5.41
Clinical waste is expected to be generated during operation
phase of the proposed welfare facilities; nursing homes for the elderly. Clinical
waste to be generated may fall under Group 1 – Used or contaminated sharps,
used in the daily care of the elderly. The estimated amount of clinical waste
to be generated is 0.002 kg/person/day
for the 100-p RCHE cum 30-p DCU. Clinical waste shall be segregated from other
sources and types of waste streams at the source, centrally collected and
stored in designated clinical waste storage rooms before collection by licensed
clinical waste collectors for disposal at a licensed disposal facility such as
the Chemical Waste Treatment Centre (CWTC). Different groups of clinical waste
shall be handled and packaged differently. For Group 1, they shall be stored in
a yellow or combination of white and yellow sharps box, with a proprietary
closure.
Chemical Waste
7.5.42
Chemical waste such as fluorescent tubes, cleaning fluid (i.e.,
detergent), solvents, waste lubricating oil and fuel etc. may be generated during maintenance activities of the proposed developments,
particularly for the utilities of the Project, such as cooling, electricity and
paints. Chemical waste should be handled and disposal of according to
the measures stipulated in the Waste Disposal (Chemical Waste) (General) Regulation
and the Code of Practice on the Packaging, Labelling and Storage of Chemical
Wastes. The quantity of chemical waste arising from the future operation of the
proposed Project is expected to be low at 5 litres per month. The chemical
waste should be collected by licenced chemical waste collectors and disposal of
at licenced waste disposal facilities such as Chemical Waste Treatment Centre
(CWTC).
7.5.43
Table 7.5.6 summarised the proposed disposal methods
of different types of waste for the operation phase.
Table 7.5.6 Summary of Waste Disposal Methods for Operation
Phase
Waste Types
|
Proposed Disposal Methods
|
General Refuse
|
· Recycle
as far as possible;
· The
remaining refuse collected by waste collectors and disposed of at landfills.
|
Clinical Waste
|
· Collected
by licensed clinical waste collectors to licensed disposal facilities i.e.,
CWTC.
|
Chemical Waste
|
· Collected
by licenced chemical waste collectors and disposal at CWTC.
|
7.5.44
As mentioned in this section, waste generated during operation
phase will be transported or disposed of at CWTC and landfills depending on
waste types. Table 7.5.7 summarises the information on waste facilities
of the Project.
Table 7.5.7 Summary of Waste Treatment and Disposal Facilities
Phase
|
Waste Type
|
Waste Facility
|
Location
|
Public Fill Reception
Facility Reception Facilities (PFRFs)
|
Construction Phase
|
Inert C&D Materials
|
Tuen Mun Area 38 Fill Bank
|
Lung Mun Road, Tuen Mun
|
Chemical Waste Treatment
Centre (CWTC)
|
Construction and Operation
Phase
|
Chemical Wastes and Clinical
Wastes
|
CWTC
|
51 Tsing Yi Road South, Tsing
Yi
|
Designated Facility (burial
site at landfill)
|
Prior to Construction Phase
|
ACMs
|
Secure burial in a landfill
site (to be handled and disposed of by Asbestos Contractor)
|
Strategic Landfill and
Refuse Transfer Stations
|
Construction and Operation
Phase
|
Non-inert C&D Materials
and General Refuse
|
NENT Landfill (transported
directly from site or from STTS)
|
Ta Kwu Ling, New Territories
|
STTS Refuse Transfer Station
|
On Hing Lane, Sha Tin
|
NWNTTS Refuse Transfer Station
|
Shun Tat Street, Tuen Mun (near
Lam Tei)
|
7.5.45
With the implementation of mitigation measures described in Section
7.6, potential environmental impacts (including potential hazards, air and
odour emissions, noise, wastewater discharge and public transport) are not
expected.
7.6
Mitigation Measures for Construction Phase
7.6.1
Based on the waste management hierarchy mentioned in Section
7.4.1, waste reduction measures are recommended as follows in order to
reduce waste generation. Recommendations of good site practices and waste
reduction measures are stated in this section.
Good Site Practices during Construction
Phase
7.6.2
Adverse impacts related to waste management such as dust,
odour, noise and wastewater discharge are not expected to arise, provided that
good site practices are strictly followed. Recommendations for good site
practices during the construction activities include:
·
Nomination of an approved person, such as a site manager, to be
responsible for good site practices, arrangements for collection and effective
disposal of all waste generated at the site to an appropriate facility.
·
Training of site personnel in proper waste management and
chemical handling procedures.
·
Provision of sufficient waste disposal points and regular
collection of waste.
·
Appropriate measures to minimise windblown litter and dust/odour
during transportation of waste by either covering trucks or by transporting
waste in enclosed containers.
·
Stockpiles of C&D materials should be kept covered by
impervious sheets to avoid wind-blown dust.
·
All dusty materials including C&D materials should be sprayed
with water immediately prior to any loading transfer operation to keep the
dusty material wet during material handling at the stockpile areas.
·
Provision of wheel washing facilities for trucks before leaving
the works area to minimise dust introduction to public roads.
·
Well planned delivery programme for offsite disposal so adverse
environmental impact from transporting inert or non-inert C&D materials is
not anticipated
·
Regular cleaning and maintenance programme for drainage systems,
sumps and oil interceptors.
·
General refuse should be removed as soon as possible and avoid
overnight accumulation and storage of general refuse.
Waste Reduction Measures
7.6.3
The generation of a significant amount of waste can be prevented
through good management and control. Waste reduction is best achieved at the
planning and design stage, as well as by ensuring the implementation of good
site practices. The following are recommendations to achieve waste reduction in
the construction phase:
·
Prepare and submit a C&DMMP to PFC for approval in order to
manage and monitor the C&D materials generation.
·
Segregate inert C&D materials from non-inert C&D
materials for reuse.
·
Segregate any other recyclable materials (i.e., metal) from
non-inert C&D materials for recycling.
·
Segregation and storage of different types of waste in different
containers or skips or stockpiles to enhance reuse or recycling of materials
and their proper disposal.
·
Encourage collection of recyclable waste such as waste paper and
aluminium cans by providing separate labelled bins to enable such waste to be
segregated from other general refuse generated by the workforce.
·
Any unused chemicals or those with remaining functional capacity
shall be recycled, and separation of chemical wastes for special handling and
appropriate treatment Proper site practices to minimise the potential for
damage or contamination of inert C&D materials.
·
Plan the use of construction materials carefully to minimise
amount of waste generated and avoid unnecessary generation of waste.
·
Provide training to workers about the concepts of site
cleanliness and appropriate waste management procedures, including waste
reduce, reuse and recycling (3Rs).
·
Prior to disposal of non-inert C&D material, it is
recommended that wood, steel and other metals to be separated for reuse and/or
recycling to minimise the quantity of waste going to landfills.
7.6.4
The Contractor shall prepare and implement a WMP as part of
the EMP in accordance with ETWB TCW No. 19/2005 detailing arrangements for
avoidance, recycling, reuse, collection, treatment and disposal of different
types of waste. The EMP should be submitted to the Engineer for approval. The
Contractor should implement the waste management practices mentioned in the WMP
throughout the entire construction stage of the Project. The WMP must be
reviewed regularly and updated by the Contractor.
7.6.5
In addition to the above measures, specific mitigation
measures are recommended below for the identified waste arising to minimise
environmental impacts during storage, collection, transportation and disposal
of these wastes.
Storage, Collection and
Transportation of Waste
7.6.6
Materials stored on-site would give rise to adverse
environmental impacts if they are not properly managed. Recommendations to
minimise the impacts include:
· Clean
the waste storage areas routinely.
· Soil
should be stored well in secured containment facilities.
· Storage
areas should be covered and provided with a water spraying system to prevent
materials being blown away.
7.6.7
Waste should be collected by licenced collectors employed by
the Contractor for the collection and transportation of waste from the work
area to the respective disposal site. Recommendations to minimise the impacts
include:
· Remove
the waste as soon as possible.
· Use
enclosed containers or covered trucks for waste transportation in order to
minimise the impacts during transportation.
· Relevant
permits should be obtained by the waste collector prior to waste collection.
· Record
the amount of waste generated, recycled and disposed.
Construction and Demolition
(C&D) Materials
7.6.8
In order to minimise impacts resulting from collection and
transportation of inert C&D materials for off-site disposal, the inert
C&D materials (particularly excavated soil) should be reused on-site as
fill material as far as practicable. In addition, inert C&D materials
generated from excavation works could be reused as fill materials in local
projects that require Public Fill Reception Facilities (PFRFs) for reclamation.
7.6.9
The surplus inert C&D materials will be disposed of at
the Government’s PFRFs for beneficial use by other projects in Hong Kong. The
C&D materials generated from general site clearance should be sorted on
site to segregate any inert C&D materials for reuse or disposal of at PFRFs
whereas the non-recyclable non-inert materials will be disposed of at the
designated landfill site.
7.6.10
In order to monitor the disposal of inert C&D materials
and non-recyclable non-inert C&D waste respectively at PFRFs and the designated
landfill site, and to control fly-tipping, it is recommended that the
Contractor follow the DEVB Technical Circular (Works) No. 6/2010 for Trip
Ticket System for Disposal of Construction & Demolition Materials issued by
Development Bureau. In addition, it is also recommended that the Contractor
prepare and implement a Waste Management Plan detailing their various waste
arising and waste management practices in accordance with the relevant
requirements of the ETWB Technical Circular (Works) No. 19/2005 Environmental
Management on Construction Site. The WMP becomes part of the Environmental
Management Plan (EMP) for architect/engineer’s approval before construction
works.
Chemical Waste
7.6.11
When chemical wastes are produced at the construction site,
the Contractor will be required to register with the EPD as a chemical waste
producer and follow the guidelines stated in the “Code of Practice on the
Packaging Labelling and Storage of Chemical Wastes”. Good quality containers
compatible with the chemical waste should be used, and incompatible chemicals
should be stored separately. Appropriate labels should be securely attached on
each chemical waste container indicating the corresponding chemical
characteristics of the chemical waste, such as flammable, oxidising, irritant,
toxic, harmful, corrosive, etc. The Contractor should use a licenced chemical
waste collector to transport and dispose of the chemical waste at the approved
Chemical Waste Treatment Centre or other licenced recycling facilities, in
accordance with the Waste Disposal (Chemical Waste) (General) Regulation.
7.6.12
Potential environmental impacts arising from the handling
activities (including storage, collection, transportation and disposal of
chemical waste) are expected to be minimal with the implementation of
appropriate mitigation measures as recommended.
Asbestos-Containing
Materials (ACMs)
7.6.13
ACMs may be encountered during demolition of buildings and
site clearance activities, and an asbestos investigation is required. An
asbestos specialist shall be employed during construction phase to investigate
this issue.
7.6.14
Sufficient and reasonable lead time shall be allowed for the
preparation, vetting and implementation of the AIR and AAP in accordance with
the Air Pollution Control Ordinance (Cap. 311), before commencement of
any demolition or site clearance work.
7.6.15
Some key precautionary measures related to the handling and
disposal of asbestos based on Handling of Asbestos Containing Materials in
Buildings (ProPECC PN2/97) are listed as follow:
·
Adoption of protection, such as full containment, mini
containment, or segregation of work area;
·
Provision of decontamination facilities for cleaning of works,
equipment and bagged waste before leaving the work area;
·
Adoption of engineering control techniques to prevent fibre
release from work area, such as use of negative pressure equipment with high
efficiency particulate air (HEPA) filters to control air flow between the work
area and the outside environment;
·
Wetting of ACMs before and during disturbance, minimizing the
breakage and dropping of ACMs, and packing of debris and waste immediately
after it is produced;
·
Cleaning the work area by wet wiping and vacuuming with
HEPA-filtered vacuum cleaner;
·
Coating on surfaces previously in contact with or contained by
asbestos with a sealant;
·
Proper bagging, safe storage and disposal of asbestos and asbestos-containing
waste;
·
Pre-treatment of all effluent from the work area before
discharged; and
·
Implement air monitoring to check the leakage and clearance of
the work area during and after the asbestos work.
7.6.16
The proper handling and disposal of ACMs will be carried out
in accordance with EPD’s Code of Practice on Handling, Transportation and
Disposal of Asbestos Waste and Practice Note for Professional Persons –
Handling of ACM in Buildings.
Potential Contamination from
Equipment Spillage or Leakage
7.6.17
It is considered unlikely that contaminated land issues,
subject to site investigation, would be a concern during either the
construction or operation of the proposed development as remediation on
contaminated areas would be carried out prior to construction (the evaluation
of residual impact of land contamination assessment can be referred to Section
8.7). However, as a precautionary measure, standard good site practices shall also
be observed during construction phase as spillage or leakage from construction
plants, equipment or chemicals may pose potential contamination to the soil
and/or groundwater.
General Refuse
7.6.18
During construction, general refuse should be segregated at
source for recyclable and non-recyclable waste to be stored in either
tri-coloured recycling bins or general refuse bins. Bins shall be enclosed or
in the form of compaction units separated from inert C&D materials. A
reputable waste collector should be employed by the Contractor to remove
recyclable and non-recyclable general refuse from the site, separately from
inert C&D materials. Preferably an enclosed and covered area should be
provided to reduce the occurrence of 'wind-blown' light material.
7.7.1
Mitigation measures are implemented for the identified types
of waste in order to minimise the potential adverse impacts to the environment
during operation phase and are listed below:
General Refuse
7.7.2
As mentioned in Section 7.5.40, general refuse is
estimated at 34 tpd and is the main waste type which would be generated during
operation phase. General refuse should be collected on a daily basis and
delivered to the refuse collection point accordingly. A reputable waste
collector (either private or public) should be employed to remove general
refuse regularly to avoid odour nuisance or pest/vermin problems. Sufficient
recycling containers are recommended to be provided at suitable and noticeable locations
in the area to encourage recycling of waste such as aluminium cans, plastics bottles
and wastepaper. The management offices of the new development should minimise
the amount of waste to be disposed of at landfill and maximise the recovery of
materials from the waste stream.
7.7.3
Based on the estimated total general waste generation of 34 tpd
and the current waste intakes of serving waste facilities (refer to Table 7.3.2),
in addition to an effectual waste prevention and recycling programme, problems
in accommodating the waste generated is not anticipated to cause significant
environmental impacts. It is estimated that 19% of general
refuse produced shall be recycled (6.5 tpd) and amounting 27.5 tpd for final
disposal. Assuming the transfer of all general refuse to one waste facility,
the proposed development may increase the waste intake of STTS, NENT or NWNTTS
to 1,682.5 tpd, 6,027.5 tpd or 1,287.5 tpd, respectively.
Chemical Waste
7.7.4
In the case of chemical waste being generated, the operator
should register with EPD as a Chemical Waste Producer. The chemical waste
should be collected periodically in drum-type containers and disposed of at
CWTC at Tsing Yi by licenced chemical waste collectors. With proper handling,
storage and disposal of the chemical waste, no adverse environmental impact is
expected to be generated
7.7.5
The Waste Disposal (Chemical Waste) (General) Regulation and
the Code of Practice on the Packaging, Labelling and Storage of Chemical Wastes
shall be followed when implementing a trip-ticket system by the operator to
monitor the chemical waste disposal process.
Clinical Waste
7.7.6
In accordance with the Code of Practice for the Management of
Clinical Waste - Small Clinical Waste Producers (June 2010), clinical waste
shall be properly separated from other waste, packed, labelled, centrally
collected and stored in designated clinical waste storage rooms. Clinical waste
shall be collected by licensed clinical waste collectors for disposal at the
licensed disposal facility. It is the responsibility of the management of
welfare facilities to find the list of licensed waste collectors (as provided
on EPD’s website) and implement adequate clinical waste collection at regular
intervals.
7.8.1
With the implementation of recommended mitigation measures
for the handling, transportation and disposal of the identified waste, adverse
residual waste management implications are not anticipated for both the
construction and operation phases.
7.9.1
The Contractor is responsible for ensuring all waste
generated are stored, handled and disposed of in accordance with good waste
management practices, relevant guidelines and legislation during the
construction period.
7.9.2
A WMP should be prepared as part of the EMP in accordance
with ETWB TC(W) No.19/2005 and submitted to the Engineer for approval. The
recommended mitigation measures should form the basis of the WMP. The
monitoring and auditing requirement stated in ETWB TC(W) No.19/2005 should be
followed regarding the management of C&D materials.
7.9.3
General refuse is the main waste type which would be
generated during operation phase, however, adverse environmental impacts would
not be anticipated by implementation of good waste management practices,
sufficient capacity of serving waste disposal facilities, a waste reduction and
recycling programme.
Construction Phase
7.10.2
Potential waste management implications from the generation
of waste during the construction phase have been evaluated. Mitigation
measures, including the opportunity for on-site sorting, reusing excavated
clean soil and fill materials are devised in the construction method to
minimise the surplus materials to be disposed. Recommendations have been made
for implementation by the Contractor during the construction period to minimise
waste generation and off-site disposal. The disposal quantities for C&D
materials and their disposal methods have also been assessed.
7.10.3
An estimated total of 950,000 m3 of C&D
materials are expected to be generated, of which 620,000 m3 are
inert C&D materials and 330,000 m3 are non-inert C&D
materials. Out of the non-inert C&D materials (clean soil) 56,000 m3
is expected to be reused on-site. 50,000 m3 of inert C&D
materials is expected to reuse on-site and 570,000 m3 is estimated to
be disposed of at the Public Fill Reception Facility (Tuen Mun Area 38 Fill
Bank), whereas 66,000 m3 of non-inert C&D materials shall be
recycled prior to off-site disposal and 208,000 m3 of non-inert
C&D materials shall be disposed of at designated landfill (NENT).
7.10.4
Construction waste is suggested to be on-site recycled and
reused as much as possible. Various waste management measures and good site
practices also provided to reduce the volume of waste. Provided that the waste
is managed by implementing all the recommended measures, no unacceptable
adverse environmental impacts arising from the handling, storage,
transportation or disposal of the waste generated by the Project would be
envisaged.
Operation Phase
7.10.7
The types of waste that would be generated during the
operation phase have been assessed. Recommendations have been made to ensure
proper treatment and waste disposal.
7.10.8
From operation phase, general refuse is the main waste type
which would be generated from the operation of housing site, other waste types
include clinical waste and chemical waste is also expected. Approximately 34 tpd
general refuse shall be generated, of which 6.5 tpd shall be recycled and 27.5
tpd for final disposal. The amount of general refuse going to landfills should
be minimised and the recovery of materials from the waste stream should be
maximised.
7.10.9
Clinical and chemical wastes are anticipated from the
operation of welfare facilities. Clinical waste shall
be segregated from other sources and types of waste streams at the source,
centrally collected and stored in designated clinical waste storage rooms
before collection by licensed clinical waste collectors for disposal at a
licensed disposal facility such as the CWTC. It is the
responsibility of the management of welfare facilities to find the list of
licensed waste collectors (as provided on EPD’s website) and implement adequate
clinical waste collection at regular intervals.
7.10.10
Chemical waste shall be handled and disposal of according to
the measures stipulated in the Waste Disposal (Chemical Waste) (General)
Regulation, and the Code of Practice on the Packaging, Labelling and Storage of
Chemical Wastes shall also be observed. Chemical wastes shall
be collected periodically in drum-type containers and disposed of at CWTC at
Tsing Yi by licensed chemical waste collectors.