GENERAL NOTES:

1. THE PETROL INTERCEPTOR IS DISIGNED TO PROVIDE A7 LEAST 20 MINUTES RETENTION TO 5-10 OR THE MAXIMUM RUNOFT COLLECTED BY THE TRANSPORT INTERCMANGE IN A 1 IN 2 YEAR RAINSTORM.
2. DETAILS OF PETROL INTERCEPTOR SHOWN IN THESE DRAWING IS FOR OPEN SPACE PUBLIC TRANSPORT INTERCHANGE. FOR PETROL INTERCEPTOR AT COVERED FUBLIC TRANSPORT INTERCHANGE SEL CEO STANDARD DRAWING CE 1041.
3. ALL DIMENSIONS ARE IN MILLIMETRES.
4. CONCRITE TO BE GRADE 30/20.
5. REINFORCEMENT SHALL COMPLY TO BS 4449 AND SHALL BE BENT IN ACCORDANCE WITH BS 4466.
6. COVER TO REINFORCEMENT TO BE 55 mm UNLESS OTHERWISE SPECIFIED.
7. REINFORCEMENT NOTATION:

Image

  BAR CLASS -
SUFFIX - - -
R -
T -
B -
NF -
FF -
EF -
GRADE 250 PLAIN ROUND STEEL BAR
TOP
BOTTOM
NEAR FACE
FAR FACE
EACH FACE
8. MINIMUM LAP LENGTH : 40 DIAMETER OF BAR FOR MILD STEEL PLAIN BAR.
9. STAUCTURAL STEELWORX SHALL BE GRADE 43C COMPLY WITH BS 4360 UNLESS OTHERWISE SPECIFIED.
10. ALL FILLET WELDS TO BE 6 mm UNLESS OTHERWISE SPECIFIED.
11. STAINLESS STEEL ACCESS LADDER TO BE OF MINIMUM GRADE 304 S12 TO BS 970:FT1:1983.
12. FOR RSJ CONNECTIONS, SEE CEO STANDARD DRAWING CE 1020.
13. FOR DETAILS OF TO TREATMENT TO PETROL INTERCEPTOR, SEE CEO STANDARD DRAWING CE 1021 FOR FLEXISLE ROAD SURFACE AND HIGHWAY STANDARD DRAWING H 1006 FOR CONCRETE ROAD SLAS.
14. FOR DETAILS OF COVER TO PETROL INTERCEPTOR, SEE CEO STANDARD DRAWING CE 1022.
15. FOR DETAILS OF DESILTING OPENING COVER, SEE CEO STANDARD DRAWING CE 1023.