Bursting system can be used for concrete breaking to replace traditional handheld percussive breakers. It speeds up the demolition process and shortens the duration of noise production.
Courtesy of Modern Concrete Drill Cut Co., Ltd.
A lot of foundation works involved noisy activities, such as excavation/site formation, rock breaking and piling works. Typically, sound power levels of excavator/loader, bulldozer, excavator mounted breaker and piling machines can reach about 112 dB(A). Quieter equipment or methods are commercially available, which can significantly reduce the noise emission from the foundation works.
Noise reduction for some mitigation measures for reference.
Bursting system can be used for concrete breaking to replace traditional handheld percussive breakers. It speeds up the demolition process and shortens the duration of noise production.
Courtesy of Modern Concrete Drill Cut Co., Ltd.
Sound pressure level in dB(A) at 7m from equipment | 70-72dB(A) |