Construction Phase
(a) General Construction Works during Non-Restricted Hours
Table 4.1 EIAO-TM Noise Standards for Daytime Construction Activities
Uses |
Noise Standards (Leq(30min) dB(A)) |
0700 to 1900 hours on any day not being |
|
· All domestic premises; · Temporary housing accommodation; · Hostels; · Convalescent homes; and · Homes for the aged. |
75 |
· Places of public worship; · Courts of law; and · Hospitals and medical clinics. |
70 |
· Educational institutions (including kindergartens and nurseries) |
70 |
65 (During examinations) |
|
Notes: 1. The above standards apply to uses which rely on opened windows for ventilation and are assessed at 1m from the external façade. 2. A Construction Noise Permit shall be required for carrying out relevant construction work during restricted hours under the Noise Control Ordinance. In case the applicant would like to evaluate whether carrying out relevant construction works during restricted hours under the Noise Control Ordinance is feasible or not in the context of programming construction works, reference should be made to relevant technical memoranda issued under the Noise Control Ordinance. |
(b) General Construction Works during Restricted Hours
Table 4.2 Area Sensitivity Ratings (ASRs)
Types of Area Containing NSR |
Degree to which NSR is affected by Influencing Factor (IF) |
||
Not Affected |
Indirectly Affected |
Directly Affected |
|
Rural area, including Country Parks or village type developments |
A |
B |
B |
Low density residential area consisting of low-rise or isolated high-rise developments |
A |
B |
C |
Urban area |
B |
C |
C |
Area other than those above |
B |
B |
C |
Notes: The following definitions apply: (a) "Country Park" means an area that is designated as a country park pursuant to section 14 of the Country Parks Ordinance; (b) "Directly affected" means that the NSR is at such a location that noise generated by the IF is readily noticeable at the NSR and is a dominant feature of the noise climate of the NSR; (c) "Indirectly affected" means that the NSR is at such a location that noise generated by the IF, whilst noticeable at the NSR, is not a dominant feature of the noise climate of the NSR; (d) "Not affected" means that the NSR is at such a location that noise generated by the IF is not noticeable at the NSR; and (e) "Urban area" means an area of high density, diverse development including a mixture of such elements as industrial activities, major trade or commercial activities and residential premises. |
Table 4.3 Basic Noise Levels of General Construction Works
Time Period |
LAeq, 5min (dB(A)) |
||
ASR ‘A’ |
ASR ‘B’ |
ASR ‘C’ |
|
All days during the evening (1900 to 2300 hours), and general holidays (including Sundays) during the daytime and evening (0700 to 2300 hours) |
60 |
65 |
70 |
All days during the night-time (2300 to 0700 hours) |
45 |
50 |
55 |
(c) Percussive Piling
Table 4.4 Noise Standards for Road Traffic Noise
Common Uses |
Road Traffic Noise Peak Hour
Traffic |
· All domestic premises; · Temporary housing accommodation; · Hostels; · Convalescent homes; and · Homes for the aged. |
70 |
· Educational institutions (including kindergartens and nurseries); · Places of public worship; and · Courts of law. |
65 |
· Hospitals and medical clinics |
55 |
Note: 1. The above standards, or equivalent, apply to uses which rely on opened windows for ventilation and are assessed at 1m from the external façade. |
Table 4.5 Construction Activities
Location/Task |
Activity |
|
All Works Areas |
(i) Tree Felling & Site Clearance |
|
Lift Shaft and Staircases (near San Wan Road) |
(i) Predrilling(ii) UU Diversion(iii) Piling(iv) Excavation and Lateral Support (ELS) System(v) Pile Caps(vi) Superstructure(vii) Lift & E&M Installation(viii) Architectural Builders Works and Finishes (ABWF) Works(ix) Connection Works with Existing So Kwun Po Road |
|
Skating Rink |
(i) Reprovision of Skating Rink |
|
Footpath & Cycle Track |
(i) Site Clearance & Site Formation(ii) Construction of Footpath & Cycling Track |
|
Box Culvert at North District Park, San Wan Road |
Box Culvert Section near North District Park(i) ELS System(ii) Temporary Drainage Diversion & Reconstruction of Box CulvertBox Culvert Section near San Wan Road (i) ELS (ii) Temporary Drainage Diversion & Reconstruction of Box Culvert |
|
At-grade Road Construction (Northern Portion) |
Retaining Wall Portion and Road Construction(i) UU Diversion(ii) ELS System(iii) Construction of Retaining Wall(iv) Street Furniture, Road Surfacing & Road Marking Subway Construction under SKPR and Road Re-construction at SKPR (i) ELS System(ii) Predrilling for Subway Construction(iii) Piling for Subway Construction (Phase 1)(iv) Piling for Subway Construction (Phase 2)(v) Subway Construction(vi) Backfilling to Final Road Level of SKPR(vii) Street Furniture, Road Surfacing & Road Marking |
|
So Kwun Po Link (SKPL) (Bridge Portion) |
(i) Predrilling(ii) Piling (Phase 1)(iii) Piling (Phase 2)(iv) ELS System(v) Pile Caps(vi) Abutments & Piers(vii) Bridge Deck(viii) Street Furniture, Road Surfacing & Road Marking |
|
At-grade Road Construction (Southern Portion) |
Slip Road between Fanling Highway and Pak Wo Road Retaining Wall Portion (i) UU Diversion(ii) ELS System(iii) Construction of Retaining Wall(iv) Street Furniture, Road Surfacing & Road Marking Elevated Road Portion (Stage 1) (i) Predrilling(ii) Piling(iii) ELS System(iv) Pile Caps & Portals(v) Bridge Deck(vi) Street Furniture, Road Surfacing & Road MarkingElevated Road Portion (Stage 2) (i) Partial Demolition of Existing SKPR Bridge(ii) Predrilling(iii) Piling(iv) ELS System(v) Pile Caps & Portals(vi) Bridge Deck(vii) Street Furniture, Road Surfacing & Road MarkingSo Kwun Po Link (SKPL) N/B Retaining Wall Portion (i) UU Diversion(ii) ELS System(iii) Construction of Retaining Wall and Formation of Temp Road(iv) Backfilling to Final Road Level (v) Street Furniture, Road Surfacing & Road Marking Elevated Road Portion (i) Partial Demolition of Existing SKPR Bridge(ii) Predrilling(iii) Piling(iv) ELS System(v) Pile Caps(vi) Formation of Temp Road(vii) Abutment and Pier Construction(viii) Bridge Deck(ix) Street Furniture, Road Surfacing & Road MarkingSKPL S/B & Diverted So Kwun Po Road (SKPR) S/B Retaining Wall Portion (i) UU Diversion(ii) ELS System(iii) Construction of Retaining Wall(iv) Street Furniture, Road Surfacing & Road MarkingElevated Road Portion (i) Predrilling(ii) Piling(iii) ELS System(iv) Pile Caps & Abutment(v) Bridge Deck(vi) Street Furniture, Road Surfacing & Road Marking |
|
Subway A (Near Pak Wo Road) |
(i) Predrilling(ii) ELS System(iii) Pile Caps, Lift Shaft, Staircase and Subway(iv) Subway(v) Lift and E&M Installation(vi) ABWF Works |
|
Improvement Works at Pak Wo Road |
(i) UU Diversion(ii) Road Improvement Works |
|
Landscape and Establishment Works |
(i) Landscape and Establishment Works |
|
Note: 1. Should percussive piling be required under this Project, CNP(s) shall be applied prior to commencement of percussive piling and mitigation measure(s) required under the enforced CNP(s) shall be strictly implemented to minimise the noise impact. |
|
· Housing Development in Ching Hiu Road;
· Housing Development in Fanling Area 17;
· Expansion of North District Hospital;
· Utilities Works and Junction Improvement Works for Partial Development of Fanling Golf Course Site; and
· Reclaimed Water Supply to Sheung Shui and Fanling.
Table 4.6 Summary of Construction Noise Assessment Results – Unmitigated
Table 4.7 Summary of affected NSRs requiring Direct Noise Mitigation Measures
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
|||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
AMALS |
TWGHs Hong Kong and Kowloon Electrical Appliances Merchants Association Limited School |
AMALS1_1 |
12.5 |
Educational Institution |
65 |
66 |
59 |
65 |
1.2 |
No |
Yes |
Yes |
66 |
60 |
65 |
1.1 |
No |
Yes |
Yes |
AMALS1_2 |
15.8 |
68 |
62 |
67 |
1.2 |
No |
Yes |
Yes |
69 |
62 |
67 |
1.1 |
No |
Yes |
Yes |
||||
AMALS1_3 |
19.1 |
70 |
63 |
68 |
1.1 |
No |
Yes |
Yes |
70 |
63 |
69 |
1.1 |
No |
Yes |
Yes |
||||
AMALS1_4 |
22.4 |
70 |
64 |
69 |
1.1 |
No |
Yes |
Yes |
71 |
64 |
70 |
1.1 |
No |
Yes |
Yes |
||||
AMALS1_5 |
25.7 |
71 |
65 |
70 |
1.1 |
No |
Yes |
Yes |
71 |
65 |
70 |
1.1 |
No |
Yes |
Yes |
||||
AMALS1_6 |
29.0 |
71 |
65 |
70 |
1.2 |
No |
Yes |
Yes |
72 |
65 |
71 |
1.1 |
No |
Yes |
Yes |
||||
AMALS1_7 |
32.3 |
72 |
65 |
71 |
1.1 |
No |
Yes |
Yes |
72 |
66 |
71 |
1.1 |
Yes |
Yes |
Yes |
||||
AMALS2_3 |
19.1 |
69 |
62 |
68 |
1.0 |
No |
Yes |
Yes |
69 |
63 |
68 |
1.0 |
No |
Yes |
Yes |
||||
AMALS2_4 |
22.4 |
71 |
65 |
70 |
1.1 |
No |
Yes |
Yes |
71 |
65 |
70 |
1.1 |
No |
Yes |
Yes |
||||
AMALS2_5 |
25.7 |
72 |
65 |
71 |
1.1 |
No |
Yes |
Yes |
72 |
65 |
71 |
1.1 |
No |
Yes |
Yes |
||||
AMALS2_6 |
29.0 |
72 |
65 |
71 |
1.1 |
No |
Yes |
Yes |
72 |
66 |
71 |
1.1 |
Yes |
Yes |
Yes |
||||
AMALS2_7 |
32.3 |
72 |
66 |
71 |
1.1 |
Yes |
Yes |
Yes |
72 |
66 |
71 |
1.1 |
Yes |
Yes |
Yes |
||||
SSDSQ |
Sheung Shui Disciplined Services Quarters Block B |
SSDSQ1_4 |
25.4 |
Residential |
70 |
71 |
65 |
69 |
1.3 |
No |
Yes |
Yes |
70 |
64 |
69 |
1.1 |
No |
No |
No |
SSDSQ1_5 |
28.2 |
71 |
65 |
70 |
1.3 |
No |
Yes |
Yes |
71 |
65 |
70 |
1.1 |
No |
Yes |
Yes |
||||
SSDSQ1_6 |
31.0 |
72 |
66 |
71 |
1.4 |
No |
Yes |
Yes |
72 |
66 |
71 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_7 |
33.8 |
72 |
67 |
71 |
1.5 |
No |
Yes |
Yes |
72 |
66 |
71 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_8 |
36.6 |
73 |
67 |
71 |
1.4 |
No |
Yes |
Yes |
73 |
67 |
71 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_9 |
39.4 |
73 |
68 |
72 |
1.5 |
No |
Yes |
Yes |
73 |
67 |
72 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_10 |
42.2 |
73 |
68 |
72 |
1.5 |
No |
Yes |
Yes |
73 |
67 |
72 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_11 |
45.0 |
74 |
68 |
72 |
1.4 |
No |
Yes |
Yes |
73 |
68 |
72 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_12 |
47.8 |
74 |
68 |
72 |
1.5 |
No |
Yes |
Yes |
74 |
68 |
72 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_13 |
50.6 |
74 |
68 |
72 |
1.5 |
No |
Yes |
Yes |
74 |
68 |
72 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_14 |
53.4 |
74 |
68 |
72 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
72 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_15 |
56.2 |
74 |
68 |
73 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_16 |
59.0 |
74 |
68 |
73 |
1.5 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_17 |
61.8 |
74 |
68 |
73 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_18 |
64.6 |
74 |
68 |
73 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
||||
SSDSQ1_19 |
67.4 |
74 |
68 |
73 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_20 |
70.2 |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_21 |
73.0 |
74 |
68 |
73 |
1.4 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_22 |
75.8 |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.1 |
No |
Yes |
Yes |
||||
SSDSQ1_23 |
78.6 |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
||||
SSDSQ1_24 |
81.4 |
74 |
68 |
73 |
1.2 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.1 |
No |
Yes |
Yes |
||||
SSDSQ1_25 |
84.2 |
74 |
68 |
73 |
1.3 |
No |
Yes |
Yes |
74 |
68 |
73 |
1.1 |
No |
Yes |
Yes |
||||
NSR |
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
SSGSS |
Sheung Shui Government Secondary School |
SSGSS1_2 |
15.9 |
Educational Institution |
65 |
67 |
63 |
64 |
2.3 |
No |
Yes |
Yes |
67 |
62 |
65 |
1.9 |
No |
Yes |
Yes |
SSGSS1_3 |
19.4 |
68 |
64 |
66 |
2.2 |
No |
Yes |
Yes |
68 |
63 |
66 |
1.9 |
No |
Yes |
Yes |
||||
SSGSS1_4 |
22.9 |
69 |
65 |
66 |
2.4 |
No |
Yes |
Yes |
69 |
64 |
67 |
2.0 |
No |
Yes |
Yes |
||||
SSGSS1_5 |
26.4 |
70 |
66 |
67 |
2.6 |
Yes |
Yes |
Yes |
69 |
65 |
67 |
2.1 |
No |
Yes |
Yes |
||||
SSGSS1_6 |
29.9 |
70 |
67 |
67 |
2.7 |
Yes |
Yes |
Yes |
70 |
66 |
68 |
2.3 |
Yes |
Yes |
Yes |
||||
SSGSS1_7 |
33.4 |
71 |
67 |
68 |
2.7 |
Yes |
Yes |
Yes |
70 |
67 |
68 |
2.3 |
Yes |
Yes |
Yes |
||||
SSGSS2_3 |
19.4 |
67 |
63 |
64 |
2.8 |
No |
Yes |
Yes |
66 |
63 |
64 |
2.6 |
No |
Yes |
Yes |
||||
SSGSS2_4 |
22.9 |
68 |
65 |
65 |
2.9 |
No |
Yes |
Yes |
67 |
64 |
65 |
2.7 |
No |
Yes |
Yes |
||||
SSGSS2_5 |
26.4 |
69 |
66 |
66 |
2.7 |
Yes |
Yes |
Yes |
69 |
65 |
66 |
2.4 |
No |
Yes |
Yes |
||||
SSGSS2_6 |
29.9 |
70 |
67 |
68 |
2.5 |
Yes |
Yes |
Yes |
70 |
66 |
67 |
2.4 |
Yes |
Yes |
Yes |
||||
SSGSS2_7 |
33.4 |
71 |
67 |
68 |
2.5 |
Yes |
Yes |
Yes |
70 |
66 |
68 |
2.3 |
Yes |
Yes |
Yes |
||||
SSGSS3_7 |
33.4 |
72 |
65 |
71 |
1.0 |
No |
Yes |
Yes |
72 |
65 |
72 |
0.8 |
No |
Yes |
No |
||||
SKHWCPS |
S.K.H. Wing Chun Primary School |
SKHWCPS_6 |
29.7 |
Educational Institution |
65 |
74 |
66 |
73 |
0.8 |
Yes |
Yes |
Yes |
74 |
65 |
73 |
0.6 |
No |
Yes |
No |
SKHWCPS_7 |
33.2 |
75 |
67 |
74 |
0.7 |
Yes |
Yes |
Yes |
75 |
66 |
74 |
0.6 |
Yes |
Yes |
Yes |
NSR |
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Direct Mitigation measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
ViG |
Vienna Garden Block 1 |
ViG1_1 |
15.5 |
Residential |
70 |
74 |
71 |
71 |
2.7 |
Yes |
Yes |
Yes |
74 |
70 |
72 |
2.0 |
No |
Yes |
Yes |
ViG1_2 |
18.3 |
76 |
72 |
73 |
2.8 |
Yes |
Yes |
Yes |
76 |
72 |
74 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG1_3 |
21.1 |
76 |
73 |
73 |
2.8 |
Yes |
Yes |
Yes |
76 |
72 |
74 |
2.2 |
Yes |
Yes |
Yes |
||||
ViG1_4 |
23.9 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
73 |
74 |
2.3 |
Yes |
Yes |
Yes |
||||
ViG1_5 |
26.7 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
73 |
74 |
2.3 |
Yes |
Yes |
Yes |
||||
ViG1_6 |
29.5 |
76 |
73 |
73 |
2.8 |
Yes |
Yes |
Yes |
76 |
73 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_7 |
32.3 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
73 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_8 |
35.1 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
73 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_9 |
37.9 |
76 |
73 |
73 |
2.8 |
Yes |
Yes |
Yes |
76 |
72 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_10 |
40.7 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
72 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_11 |
43.5 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
72 |
74 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG1_12 |
46.3 |
76 |
73 |
73 |
2.9 |
Yes |
Yes |
Yes |
76 |
72 |
73 |
2.4 |
Yes |
Yes |
Yes |
||||
ViG2_1 |
15.5 |
76 |
72 |
74 |
2.2 |
Yes |
Yes |
Yes |
77 |
71 |
75 |
1.6 |
Yes |
Yes |
Yes |
||||
ViG2_2 |
18.3 |
77 |
73 |
75 |
2.2 |
Yes |
Yes |
Yes |
77 |
73 |
76 |
1.7 |
Yes |
Yes |
Yes |
||||
ViG2_3 |
21.1 |
77 |
74 |
75 |
2.2 |
Yes |
Yes |
Yes |
78 |
73 |
76 |
1.8 |
Yes |
Yes |
Yes |
||||
ViG2_4 |
23.9 |
77 |
74 |
75 |
2.3 |
Yes |
Yes |
Yes |
78 |
73 |
76 |
1.8 |
Yes |
Yes |
Yes |
||||
ViG2_5 |
26.7 |
77 |
74 |
75 |
2.3 |
Yes |
Yes |
Yes |
78 |
73 |
76 |
1.9 |
Yes |
Yes |
Yes |
||||
ViG2_6 |
29.5 |
77 |
74 |
75 |
2.3 |
Yes |
Yes |
Yes |
77 |
73 |
76 |
1.9 |
Yes |
Yes |
Yes |
||||
ViG2_7 |
32.3 |
77 |
73 |
75 |
2.4 |
Yes |
Yes |
Yes |
77 |
73 |
75 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG2_8 |
35.1 |
77 |
73 |
75 |
2.4 |
Yes |
Yes |
Yes |
77 |
73 |
75 |
1.9 |
Yes |
Yes |
Yes |
||||
ViG2_9 |
37.9 |
77 |
73 |
75 |
2.4 |
Yes |
Yes |
Yes |
77 |
73 |
75 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG2_10 |
40.7 |
77 |
73 |
74 |
2.3 |
Yes |
Yes |
Yes |
77 |
73 |
75 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG2_11 |
43.5 |
77 |
73 |
74 |
2.4 |
Yes |
Yes |
Yes |
77 |
72 |
75 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG2_12 |
46.3 |
77 |
73 |
74 |
2.4 |
Yes |
Yes |
Yes |
77 |
72 |
75 |
2.0 |
Yes |
Yes |
Yes |
||||
ViG3_6 |
29.5 |
75 |
68 |
74 |
1.0 |
No |
Yes |
Yes |
75 |
68 |
74 |
0.8 |
No |
Yes |
No |
||||
ViG3_7 |
32.3 |
75 |
68 |
74 |
1.0 |
No |
Yes |
Yes |
75 |
67 |
74 |
0.8 |
No |
Yes |
No |
||||
ViG3_8 |
35.1 |
75 |
68 |
74 |
1.0 |
No |
Yes |
Yes |
75 |
67 |
74 |
0.9 |
No |
Yes |
No |
||||
ViG3_9 |
37.9 |
74 |
68 |
73 |
1.0 |
No |
Yes |
Yes |
75 |
67 |
74 |
0.9 |
No |
Yes |
No |
||||
ViG3_10 |
40.7 |
74 |
68 |
73 |
1.0 |
No |
Yes |
Yes |
74 |
67 |
73 |
0.9 |
No |
Yes |
No |
||||
ViG3_11 |
43.5 |
74 |
67 |
73 |
1.0 |
No |
Yes |
Yes |
74 |
67 |
73 |
0.9 |
No |
Yes |
No |
||||
ViG3_12 |
46.3 |
74 |
67 |
73 |
1.0 |
No |
Yes |
Yes |
74 |
67 |
73 |
0.9 |
No |
Yes |
No |
Notes:
[1] Bold and underlined values denote exceedance over the corresponding noise criteria.
[2] Detail of Road Traffic Noise Assessment for un-mitigated scenario shall refer to Appendix 4.8.
· Concrete mixer (electric) has been adopted as a mitigation measure to replace concrete lorry mixer.
· Self-compacting concrete has been adopted such that poker is not required.
· For piling works, “Press-in” method is more preferable than the use of traditional piling methods due to lesser noise and vibration impact generated. According to the EPD web page, the noise emission of “Press-in” method is 69 dB(A) at 7 m from the silent piler, which is more than 20 dB(A) quieter than the vibratory hammer. “Press-in” method has been adopted for ELS installations.
· High level of noise impact would be encountered for sites which involve demolition works. In view of this, hydraulic crusher (SWL=94dB(A)), which is a quieter alternative to the conventional pneumatic breaker (SWL=122dB(A)), has been proposed for the partial demolition of existing SKPR bridge. The operation principle of pneumatic breaker is by percussive striking actions of its chisels, so that much more noise would be generated as compared with hydraulic crusher.
· For the works at worksites 9f(ii), 10d and 10e, i.e. in close proximity to Vienna Garden, dump truck will be shared with other worksites 9g(ii), 8(vi), 9e(iv), 9e(v) & 9f(i), i.e. dump truck will not be used at worksites 9f(ii), 10d and 10e. Material delivery or disposal will be transported manually between worksites 9f(ii), 10d and 10e and other worksites 9g(ii), 8(vi), 9e(iv), 9e(v) & 9f(i). In addition, concrete pump, stationary/lorry mounted will not be used at worksites 10d(ii) and 10e(i). concrete will be transported manually from worksite 8(vii).
Table 4.8 SWL of QPME adopted for Construction Noise Mitigation
QPME / Quiet PME |
QPME Reference Number |
Brand |
Model Number |
SWL, dB(A) |
Air Compressor |
EPD-07503 |
AIRMAN |
PDS55S-5C1 |
92 |
Hand-held Percussive Breaker |
EPD-12844 |
Hilti |
TE 1000-AVR |
99 |
Excavator, wheeled/tracked |
EPD-13134 |
YANMAR |
VIO17-1 |
91 |
Asphalt Paver |
EPD-01226R |
VOLVO |
ABG5770 |
104 |
Generator |
EPD-08951 |
DENYO |
DCA-25USI3 |
80 |
Crane, mobile |
EPD-05797 |
Maeda |
CC985S-1 |
91 |
Roller, vibratory |
EPD-09720 |
SAKAI |
SW502S-1 |
94 |
Table 4.9 Summary of Cumulative Construction Noise Assessment Results - Mitigated
NAP ID |
Description |
Type of Use |
Noise Criteria Leq (30 min), dB(A) |
Predicted Mitigated Maximum Construction Noise Level Leq (30 min), dB(A) |
|
8RG1 |
8 Royal Green |
Residential |
75 |
57 |
|
8RG2 |
8 Royal Green |
Residential |
75 |
57 |
|
AMALS1 |
TWGHs Hong Kong and Kowloon Electrical Appliances Merchants Association Limited School |
Educational Institution |
70/65 |
62 |
|
AMALS2 |
TWGHs Hong Kong and Kowloon Electrical Appliances Merchants Association Limited School |
Educational Institution |
70/65 |
63 |
|
CC |
Camellia Court |
Residential |
75 |
54 |
|
CHEE1 |
Ching Ho Estate Extension (Flat 9 - Living & Dining Room) |
Planned Residential |
75 |
63 |
|
CHEE2 |
Ching Ho Estate Extension (Flat 9 - |
Planned Residential |
75 |
63 |
|
CP1 |
Cheerful Park Block 1 |
Residential |
75 |
63 |
|
CP2 |
Cheerful Park Block 1 |
Residential |
75 |
63 |
|
CP3 |
Cheerful Park Block 2 |
Residential |
75 |
62 |
|
CP4 |
Cheerful Park Block 2 |
Residential |
75 |
62 |
|
CP5 |
Cheerful Park Block 3 |
Residential |
75 |
60 |
|
EG1 |
Eden Garden |
Residential |
75 |
72 |
|
EG2 |
Eden Garden |
Residential |
75 |
72 |
|
FW1 |
Fanling Wai |
Residential |
75 |
60 |
|
FW2 |
Fanling Wai |
Residential |
75 |
57 |
|
GG |
Glamour Garden |
Residential |
75 |
70 |
|
GPV1 |
Green Park Villa |
Residential |
75 |
56 |
|
GPV2 |
Green Park Villa |
Residential |
75 |
58 |
|
KYDC1 |
TWGHs Kap Yan Directors' College |
Educational Institution |
70/65 |
62 |
|
KYDC2 |
TWGHs Kap Yan Directors' College |
Educational Institution |
70/65 |
61 |
|
KYDC3 |
TWGHs Kap Yan Directors' College |
Educational Institution |
70/65 |
62 |
|
LST |
Ling Shan Tsuen |
Residential |
75 |
54 |
|
MKCPS1 |
TWGHs Ma Kam Chan Memorial Primary School |
Educational Institution |
70/65 |
62 |
|
MKCPS2 |
TWGHs Ma Kam Chan Memorial Primary School |
Educational Institution |
70/65 |
62 |
|
SG |
Sunningdale Garden Block 2 |
Residential |
75 |
56 |
|
SKHCYSS |
S.K.H Chan Young Secondary School |
Educational Institution |
70/65 |
59 |
|
SKHWCPS |
S.K.H. Wing Chun Primary School |
Educational Institution |
70/65 |
70 |
|
SKP1 |
So Kwun Po |
Residential |
75 |
66 |
|
SKP2 |
So Kwun Po |
Residential |
75 |
65 |
|
SKP3 |
So Kwun Po |
Residential |
75 |
66 |
|
SSC |
Sheung Shui Centre Block 4 |
Residential |
75 |
57 |
|
SSDSQ1 |
Sheung Shui Disciplined Services Quarters Block B |
Residential |
75 |
63 |
|
SSDSQ2 |
Sheung Shui Disciplined Services Quarters Block B |
Residential |
75 |
62 |
|
SSGSS1 |
Sheung Shui Government Secondary School |
Educational Institution |
70/65 |
64 |
|
SSGSS2 |
Sheung Shui Government Secondary School |
Educational Institution |
70/65 |
64 |
|
SSGSS3 |
Sheung Shui Government Secondary School |
Educational Institution |
70/65 |
63 |
|
SSKPTT |
Sam Shing Kung Pak Tai Temple |
Place of Public Worship |
70 |
53 |
|
SSTC |
Sheung Shui Town Centre New York Court |
Residential |
75 |
59 |
|
THMSS |
Hong Kong Taoist Association Tang Hin Memorial Secondary School |
Educational Institution |
70/65 |
59 |
|
TKPSS1 |
Tin Ka Ping Secondary School |
Educational Institution |
70/65 |
58 |
|
TKPSS2 |
Tin Ka Ping Secondary School |
Educational Institution |
70/65 |
55 |
|
TPE |
Tin Ping Estate Block 5 Tin Mei House |
Residential |
75 |
55 |
|
ViG1 |
Vienna Garden Block 1 |
Residential |
75 |
74 |
|
ViG2 |
Vienna Garden Block 1 |
Residential |
75 |
75 |
|
ViG3 |
Vienna Garden Block 1 |
Residential |
75 |
70 |
|
ViG4 |
Vienna Garden Block 1 |
Residential |
75 |
72 |
|
ViG5 |
Vienna Garden Block 2 |
Residential |
75 |
71 |
|
YPC |
Yuk Po Court Seung Wu House |
Residential |
75 |
53 |
|
Notes: 1. Bold and underlined values denote exceedance over the corresponding noise criteria. 2. Noise criteria of 75 dB(A) for all domestic premises (including temporary housing accommodation), hotels and hostels, 70 dB(A) for educational institution and places for public worship, whereas 65 dB(A) for examination period. |
Proposed Noise Mitigation Measures |
NMM ID |
Location |
Approximate Length, m (rounded off to the nearest 10m) |
LNRS |
SKPL-LNRS1 |
SKPL |
330 |
SKPL-LNRS2 |
350 |
||
Cantilever
Barrier |
SKPL-7.5mVCB1 |
80 |
|
Cantilever
Barrier |
SKPL-7.5mVCB2 |
170 |
|
3m Vertical Barrier |
SKPL-3mVB1 |
100 |
|
3m Vertical Barrier |
SKPL-3mVB2 |
80 |
|
5m Vertical Barrier |
SKPL-5mVB1 |
90 |
|
LNRS |
SKPRNB-LNRS1 |
SKPR
|
110 |
3m Vertical Barrier |
SKPRNB-3mVB1 |
100 |
|
5m Vertical Barrier |
SKPRNB-5mVB1 |
50 |
|
Note: 1. Noise barriers with absorptive panels will be adopted to meet the requirements given in “Guidelines on Design of Noise Barriers”. |
Table 4.11 Summary of affected NSRs after Direct Noise Mitigation Measures
NSR |
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
AMALS |
TWGHs Hong Kong and Kowloon Electrical Appliances Merchants Association Limited School |
AMALS1_1 |
12.5 |
Educational Institution |
65 |
65 |
58 |
65 |
0.8 |
No |
No |
No |
66 |
58 |
65 |
0.8 |
No |
Yes |
No |
AMALS1_2 |
15.8 |
68 |
60 |
67 |
0.8 |
No |
Yes |
No |
68 |
61 |
67 |
0.8 |
No |
Yes |
No |
||||
AMALS1_3 |
19.1 |
69 |
61 |
68 |
0.8 |
No |
Yes |
No |
69 |
62 |
69 |
0.7 |
No |
Yes |
No |
||||
AMALS1_4 |
22.4 |
70 |
62 |
69 |
0.8 |
No |
Yes |
No |
70 |
63 |
70 |
0.8 |
No |
Yes |
No |
||||
AMALS1_5 |
25.7 |
71 |
63 |
70 |
0.8 |
No |
Yes |
No |
71 |
63 |
70 |
0.8 |
No |
Yes |
No |
||||
AMALS1_6 |
29.0 |
71 |
64 |
70 |
0.9 |
No |
Yes |
No |
71 |
64 |
71 |
0.9 |
No |
Yes |
No |
||||
AMALS1_7 |
32.3 |
71 |
64 |
71 |
0.8 |
No |
Yes |
No |
72 |
64 |
71 |
0.8 |
No |
Yes |
No |
||||
AMALS2_3 |
19.1 |
69 |
61 |
68 |
0.8 |
No |
Yes |
No |
69 |
61 |
68 |
0.8 |
No |
Yes |
No |
||||
AMALS2_4 |
22.4 |
71 |
63 |
70 |
0.8 |
No |
Yes |
No |
71 |
64 |
70 |
0.8 |
No |
Yes |
No |
||||
AMALS2_5 |
25.7 |
71 |
64 |
71 |
0.8 |
No |
Yes |
No |
72 |
64 |
71 |
0.9 |
No |
Yes |
No |
||||
AMALS2_6 |
29.0 |
72 |
64 |
71 |
0.8 |
No |
Yes |
No |
72 |
65 |
71 |
0.9 |
No |
Yes |
No |
||||
AMALS2_7 |
32.3 |
72 |
65 |
71 |
0.9 |
No |
Yes |
No |
72 |
65 |
71 |
0.9 |
No |
Yes |
No |
||||
SSDSQ |
Sheung Shui Disciplined Services Quarters Block B |
SSDSQ1_4 |
25.4 |
Residential |
70 |
68 |
57 |
67 |
0.4 |
No |
No |
No |
68 |
56 |
67 |
0.3 |
No |
No |
No |
SSDSQ1_5 |
28.2 |
69 |
57 |
69 |
0.3 |
No |
No |
No |
69 |
57 |
69 |
0.3 |
No |
No |
No |
||||
SSDSQ1_6 |
31.0 |
70 |
58 |
70 |
0.3 |
No |
No |
No |
70 |
58 |
70 |
0.3 |
No |
No |
No |
||||
SSDSQ1_7 |
33.8 |
71 |
59 |
70 |
0.3 |
No |
Yes |
No |
71 |
59 |
70 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_8 |
36.6 |
71 |
60 |
71 |
0.3 |
No |
Yes |
No |
71 |
60 |
71 |
0.3 |
No |
Yes |
No |
||||
SSDSQ1_9 |
39.4 |
72 |
61 |
71 |
0.4 |
No |
Yes |
No |
72 |
60 |
71 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_10 |
42.2 |
72 |
61 |
72 |
0.3 |
No |
Yes |
No |
72 |
61 |
72 |
0.3 |
No |
Yes |
No |
||||
SSDSQ1_11 |
45.0 |
72 |
61 |
72 |
0.3 |
No |
Yes |
No |
72 |
61 |
72 |
0.3 |
No |
Yes |
No |
||||
SSDSQ1_12 |
47.8 |
72 |
61 |
72 |
0.4 |
No |
Yes |
No |
72 |
61 |
72 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_13 |
50.6 |
73 |
62 |
72 |
0.4 |
No |
Yes |
No |
73 |
62 |
72 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_14 |
53.4 |
73 |
62 |
72 |
0.3 |
No |
Yes |
No |
73 |
62 |
72 |
0.3 |
No |
Yes |
No |
||||
SSDSQ1_15 |
56.2 |
73 |
62 |
72 |
0.4 |
No |
Yes |
No |
73 |
62 |
72 |
0.3 |
No |
Yes |
No |
||||
SSDSQ1_16 |
59.0 |
73 |
62 |
72 |
0.4 |
No |
Yes |
No |
73 |
62 |
72 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_17 |
61.8 |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_18 |
64.6 |
73 |
63 |
73 |
0.5 |
No |
Yes |
No |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_19 |
67.4 |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
73 |
63 |
73 |
0.5 |
No |
Yes |
No |
||||
SSDSQ1_20 |
70.2 |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
73 |
63 |
73 |
0.5 |
No |
Yes |
No |
||||
SSDSQ1_21 |
73.0 |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
73 |
63 |
73 |
0.4 |
No |
Yes |
No |
||||
SSDSQ1_22 |
75.8 |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
73 |
63 |
73 |
0.5 |
No |
Yes |
No |
||||
SSDSQ1_23 |
78.6 |
73 |
64 |
73 |
0.6 |
No |
Yes |
No |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
||||
SSDSQ1_24 |
81.4 |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
||||
SSDSQ1_25 |
84.2 |
74 |
64 |
73 |
0.6 |
No |
Yes |
No |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
||||
NSR |
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
SSGSS |
Sheung Shui Government Secondary School |
SSGSS1_2 |
15.9 |
Educational Institution |
65 |
64 |
55 |
64 |
0.6 |
No |
No |
No |
64 |
54 |
64 |
0.4 |
No |
No |
No |
SSGSS1_3 |
19.4 |
65 |
57 |
65 |
0.6 |
No |
No |
No |
65 |
56 |
65 |
0.5 |
No |
No |
No |
||||
SSGSS1_4 |
22.9 |
66 |
57 |
66 |
0.6 |
No |
Yes |
No |
66 |
57 |
66 |
0.5 |
No |
Yes |
No |
||||
SSGSS1_5 |
26.4 |
67 |
58 |
66 |
0.7 |
No |
Yes |
No |
67 |
57 |
67 |
0.5 |
No |
Yes |
No |
||||
SSGSS1_6 |
29.9 |
68 |
59 |
67 |
0.7 |
No |
Yes |
No |
68 |
58 |
67 |
0.5 |
No |
Yes |
No |
||||
SSGSS1_7 |
33.4 |
68 |
60 |
67 |
0.7 |
No |
Yes |
No |
68 |
59 |
67 |
0.6 |
No |
Yes |
No |
||||
SSGSS2_3 |
19.4 |
62 |
53 |
62 |
0.6 |
No |
No |
No |
62 |
53 |
61 |
0.6 |
No |
No |
No |
||||
SSGSS2_4 |
22.9 |
63 |
54 |
63 |
0.5 |
No |
No |
No |
63 |
54 |
63 |
0.6 |
No |
No |
No |
||||
SSGSS2_5 |
26.4 |
65 |
55 |
65 |
0.5 |
No |
No |
No |
65 |
55 |
65 |
0.5 |
No |
No |
No |
||||
SSGSS2_6 |
29.9 |
66 |
56 |
66 |
0.4 |
No |
Yes |
No |
66 |
56 |
66 |
0.4 |
No |
Yes |
No |
||||
SSGSS2_7 |
33.4 |
67 |
57 |
67 |
0.5 |
No |
Yes |
No |
67 |
57 |
67 |
0.4 |
No |
Yes |
No |
||||
SSGSS3_7 |
33.4 |
71 |
59 |
71 |
0.2 |
No |
Yes |
No |
72 |
58 |
71 |
0.2 |
No |
Yes |
No |
||||
SKHWCPS |
S.K.H. Wing Chun Primary School |
SKHWCPS_6 |
29.7 |
Educational Institution |
65 |
73 |
62 |
73 |
0.4 |
No |
Yes |
No |
73 |
61 |
73 |
0.3 |
No |
Yes |
No |
SKHWCPS_7 |
33.2 |
74 |
63 |
74 |
0.3 |
No |
Yes |
No |
75 |
63 |
74 |
0.3 |
No |
Yes |
No |
NSR |
Description |
NAP |
Assessment Point Elevation (mPD) |
Type of Use |
Noise Criteria, L10(1-hr), dB(A) |
AM Period |
PM Period |
||||||||||||
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
Predicted Noise Level in 2041 |
Project Roads Contribution |
Project Roads Exceed |
Overall Exceed |
Further Mitigation Measures required |
||||||||||
Overall |
Project Roads |
Other Roads |
Overall |
Project Roads |
Other Roads |
||||||||||||||
ViG |
Vienna Garden Block 1 |
ViG1_1 |
15.5 |
Residential |
70 |
65 |
56 |
65 |
0.5 |
No |
No |
No |
65 |
55 |
65 |
0.4 |
No |
No |
No |
ViG1_2 |
18.3 |
67 |
57 |
66 |
0.5 |
No |
No |
No |
67 |
57 |
67 |
0.4 |
No |
No |
No |
||||
ViG1_3 |
21.1 |
69 |
59 |
68 |
0.5 |
No |
No |
No |
69 |
59 |
69 |
0.5 |
No |
No |
No |
||||
ViG1_4 |
23.9 |
70 |
63 |
69 |
0.8 |
No |
No |
No |
70 |
62 |
70 |
0.7 |
No |
No |
No |
||||
ViG1_5 |
26.7 |
71 |
64 |
70 |
0.9 |
No |
Yes |
No |
71 |
64 |
71 |
0.8 |
No |
Yes |
No |
||||
ViG1_6 |
29.5 |
72 |
64 |
71 |
0.8 |
No |
Yes |
No |
73 |
64 |
72 |
0.6 |
No |
Yes |
No |
||||
ViG1_7 |
32.3 |
73 |
65 |
72 |
0.7 |
No |
Yes |
No |
73 |
64 |
73 |
0.6 |
No |
Yes |
No |
||||
ViG1_8 |
35.1 |
73 |
65 |
72 |
0.7 |
No |
Yes |
No |
74 |
64 |
73 |
0.6 |
No |
Yes |
No |
||||
ViG1_9 |
37.9 |
73 |
65 |
72 |
0.7 |
No |
Yes |
No |
74 |
65 |
73 |
0.5 |
No |
Yes |
No |
||||
ViG1_10 |
40.7 |
73 |
66 |
72 |
0.8 |
No |
Yes |
No |
74 |
65 |
73 |
0.7 |
No |
Yes |
No |
||||
ViG1_11 |
43.5 |
73 |
66 |
72 |
0.9 |
No |
Yes |
No |
74 |
66 |
73 |
0.7 |
No |
Yes |
No |
||||
ViG1_12 |
46.3 |
73 |
66 |
72 |
0.9 |
No |
Yes |
No |
74 |
66 |
73 |
0.7 |
No |
Yes |
No |
||||
ViG2_1 |
15.5 |
70 |
59 |
70 |
0.4 |
No |
No |
No |
70 |
57 |
70 |
0.2 |
No |
No |
No |
||||
ViG2_2 |
18.3 |
71 |
60 |
71 |
0.3 |
No |
Yes |
No |
71 |
59 |
71 |
0.2 |
No |
Yes |
No |
||||
ViG2_3 |
21.1 |
72 |
62 |
72 |
0.4 |
No |
Yes |
No |
72 |
61 |
72 |
0.3 |
No |
Yes |
No |
||||
ViG2_4 |
23.9 |
73 |
65 |
73 |
0.7 |
No |
Yes |
No |
73 |
64 |
73 |
0.6 |
No |
Yes |
No |
||||
ViG2_5 |
26.7 |
74 |
65 |
73 |
0.7 |
No |
Yes |
No |
74 |
65 |
74 |
0.5 |
No |
Yes |
No |
||||
ViG2_6 |
29.5 |
75 |
66 |
74 |
0.6 |
No |
Yes |
No |
75 |
65 |
75 |
0.5 |
No |
Yes |
No |
||||
ViG2_7 |
32.3 |
75 |
66 |
74 |
0.6 |
No |
Yes |
No |
75 |
66 |
75 |
0.5 |
No |
Yes |
No |
||||
ViG2_8 |
35.1 |
75 |
66 |
74 |
0.7 |
No |
Yes |
No |
75 |
66 |
75 |
0.6 |
No |
Yes |
No |
||||
ViG2_9 |
37.9 |
75 |
67 |
74 |
0.7 |
No |
Yes |
No |
75 |
66 |
75 |
0.5 |
No |
Yes |
No |
||||
ViG2_10 |
40.7 |
75 |
67 |
74 |
0.8 |
No |
Yes |
No |
75 |
66 |
75 |
0.6 |
No |
Yes |
No |
||||
ViG2_11 |
43.5 |
75 |
67 |
74 |
0.8 |
No |
Yes |
No |
75 |
66 |
74 |
0.6 |
No |
Yes |
No |
||||
ViG2_12 |
46.3 |
75 |
67 |
74 |
0.8 |
No |
Yes |
No |
75 |
67 |
74 |
0.7 |
No |
Yes |
No |
||||
ViG3_6 |
29.5 |
74 |
65 |
74 |
0.5 |
No |
Yes |
No |
74 |
64 |
74 |
0.4 |
No |
Yes |
No |
||||
ViG3_7 |
32.3 |
74 |
64 |
74 |
0.4 |
No |
Yes |
No |
74 |
64 |
74 |
0.4 |
No |
Yes |
No |
||||
ViG3_8 |
35.1 |
74 |
64 |
74 |
0.5 |
No |
Yes |
No |
74 |
64 |
74 |
0.4 |
No |
Yes |
No |
||||
ViG3_9 |
37.9 |
74 |
64 |
73 |
0.5 |
No |
Yes |
No |
74 |
64 |
74 |
0.5 |
No |
Yes |
No |
||||
ViG3_10 |
40.7 |
74 |
64 |
73 |
0.6 |
No |
Yes |
No |
74 |
64 |
73 |
0.5 |
No |
Yes |
No |
||||
ViG3_11 |
43.5 |
74 |
64 |
73 |
0.5 |
No |
Yes |
No |
74 |
64 |
73 |
0.5 |
No |
Yes |
No |
||||
ViG3_12 |
46.3 |
73 |
64 |
73 |
0.5 |
No |
Yes |
No |
73 |
63 |
73 |
0.5 |
No |
Yes |
No |
Notes:
[1] Bold and underlined values denote exceedance over the corresponding noise criteria.
[2] Detail of Road Traffic Noise Assessment for mitigated scenario shall refer to Appendix 4.13.
Table 4.12 Estimated number of NSRs benefited and protected under Mitigated Scenario
Description |
No. of Residential Dwellings |
No. of Classrooms |
No. of Other NSRs (Place of Public Worship, Accommodation / Hostel, Clinic / Home for the aged) |
Total |
Benefited |
284 |
82 |
0 |
366 |
Protected |
159 |
40 |
0 |
199 |
Notes: 1. Number of residential dwellings, classroom and other NSRs are estimated based on site observation and review of building layout. 2. Exposed – Noise Sensitive uses with unmitigated noise level greater than the relevant noise criteria. 3. Benefited – Exposed noise sensitive uses with a noise reduction of 1.0 dB(A) or greater in overall noise level with the noise mitigation measures in place. 4. Protected – Exposed noise sensitive uses with an overall noise level not greater than relevant noise criteria with the noise mitigation measures in place. |
Table 4.13 Estimated number of NSRs exposed to Exceedance
Scenario |
Estimated Number Exposed to Exceedance |
|||
No. of Residential Dwellings |
No. of Classrooms |
No. of Other NSRs (Place of Public Worship, Accommodation / Hostel, Clinic / Home for the aged) |
Total |
|
Prevailing in 2024 |
2,960 |
449 |
1 |
3,410 |
Unmitigated in 2041 |
3,119 |
489 |
1 |
3,609 |
Mitigated in 2041 |
2,960 |
449 |
1 |
3,410 |
Notes: 1. Number of residential dwellings, classroom and other NSRs are estimated based on site observation and review of building layout. 2. Exposed – Noise sensitive uses with unmitigated noise level greater than relevant noise criteria. |
Operation Phase
Construction Phase
Operation Phase